Wireless Pressure Transmitter

The ADDA-P-WX wireless pressure transmitter is designed for pressure and level monitoring in smart petroleum, smart water, smart gas, smart heating, and smart fire protection scenarios. Product details describe low-power wireless communication, no-wiring installation, local or remote parameter setting, LCD display, IP67 protection, and optional wireless communication methods.

Authoritative Qualification Certifications

We hold ISO quality certification, national high-tech enterprise qualification, China measuring instrument type approval, and explosion-proof and safety certifications to support reliable product quality.

Custom Engineering

Configurable materials, connections, signals, displays, and installation solutions for different process environments.

Wireless Pressure Transmitter

Product Overview

The ADDA-P-WX wireless pressure transmitter uses monocrystalline silicon piezoresistive sensing technology. This high-stability, high-reliability wireless instrument is suitable for pressure and level monitoring in smart petroleum, smart water, smart gas, smart heating, and smart fire protection applications. It uses ultra-low-power wireless communication and requires no signal wiring, enabling convenient installation.

Applications

1. Smart petroleum    2. Smart water

3. Smart gas    4. Smart heating

5. Smart fire protection

Product Features

Protection Grade: IP67, sealed waterproof design

Supports parameter configuration using local buttons or a remote device.

5-digit segmented LCD with a -30~70 degrees C operating temperature range. Displays pressure, battery level, wireless parameters, and other information.

Adjustable installation direction: connects to the field pipeline valve through a union or adapter, allowing the direction to be adjusted.

19Ah high-energy lithium thionyl chloride battery for long service life; optional battery and external power supply configuration.

High-gain antenna with a maximum wireless transmission distance of 2000m.

Supports private clouds and the matching cloud platform. Supports sending data to a specified IP address or website.

Ultra-low power consumption and a WDT watchdog design support stable long-term operation. Upper and lower alarm limits and dynamic-change thresholds can be configured; alarm information is reported immediately.

Supports data access through a mobile app and data reading by OPC configuration software.

Technical Specifications

Communication MethodZigbee

(SZ9/A11)

LoRaLoRaWANNB-IOT4G
Parameter ConfigurationLocalLocalLocalRemoteRemote
Power SupplyLithium thionyl chloride battery (capacity: 19Ah); default sampling interval: 3 seconds
Data Interval (minutes)51206060
Battery Life3 years3 years4 years2 years3 years
Measuring Mediumliquids, gases
Operating ModeScheduled data transmission with an adjustable transmission interval.
Threshold SettingsConfigurable pressure upper and lower limits and dynamic-change thresholds.
Measuring Range-0.1~40MPa
Accuracy Class0.1 class (default 0.25%FS; 0.1 and 0.2 accuracy classes can be customized)
Overload PressureSee the range specifications.
Process ConnectionM20*1.5 (other connections can be customized)
Temperature Compensation-20~70 degrees C
Operating EnvironmentTemperature: -30 degrees C~70 degrees C; humidity: <93%RH
Housing MaterialCast aluminum
Protection GradeIP67
Range
Pressure TypeNominal RangeMinimum RangeLower Range Limit (LRL)Upper Range Limit (URL)Overload
G40kPa2kPa-40kPa40kPa1MPa
250kPa12.5kPa-100kPa250kPa4MPa
1MPa50kPa-100kPa1MPa6MPa
3MPa150kPa-0.1MPa3MPa15MPa
10MPa500kPa-0.1MPa10MPa20MPa
40MPa2MPa-0.1MPa40MPa80MPa
A40kPa20kPa0kPa40kPa1MPa
250kPa50kPa0kPa250kPa4MPa
1MPa100kPa0kPa1MPa6MPa
3MPa300kPa0kPa3MPa10MPa
10MPa1MPa0kPa10MPa20MPa
High and low limit setting requirements: lower range value (LRV) and upper range value (URV) must be set within the lower and upper range limits

|URV-LRV | ≥ Minimum Range

Accuracy
Based on standards and reference test conditions, including best fit straight line (BFSL), hysteresis, repeatability. Calibration temperature: 20 degrees C ±5 degrees C.
Linear Output AccuracyGTD<=5±0.1% Span40kPa, 250kPa , 1 MPa,

3MPa, 10MPa, 40MPa

TD>5±(0.005+0.02TD) % Span40kPa, 250kPa, 1 MPa,

3MPa, 10MPa, 40MPa

ATD<=5±0.2% Span40kPa
±0.1% Span250kPa, 1MPa, 3MPa, 10MPa
TD>5±(0.005+0.04TD) % Span40kPa
±(0.005+0.025TD) % Span250kPa, 1MPa, 3MPa, 10MPa
Note: TD (Turn down) means turndown ratio, TD= maximum range / current range

 

Ambient Temperature Influence
Pressure TypeInfluencing QuantityRange
G± (0.075+0.005TD) %/20 degrees C of Span40kPa, 250kPa, 1 MPa,

3MPa, 10MPa, 40MPa

A± (0.1+0.005TD) %/20 degrees C of Span40kPa, 250kPa, 1MPa, 3MPa, 10MPa
Environmental Conditions
ItemCondition
Operating Ambient Temperature Range-40 degrees C ~ 85 degrees C, LCD display: -30 degrees C ~ 70 degrees C
Storage Ambient Temperature Range-40 degrees C ~ 100 degrees C, LCD display: -40 degrees C ~ 85 degrees C
Measured Medium Temperature RangeSilicone oil filling: -40 degrees C ~ 85 degrees C
Inert filling liquid: -20 degrees C ~ 80 degrees C
Operating Ambient Humidity Range5%RH~93%RH@40 degrees C
Hazardous AreaPCECCertificate No.: CE23.2876X

Ex db IIC T6 Gb

Ex tb IIIC T80 degrees C Db

Related Products

Case Showcase

Frequently Asked Questions

Find quick answers about product selection, customization, technical parameters, delivery, and support for ADDA industrial measurement instruments.

官网询盘

Please provide the measured medium, measuring range, process temperature, process pressure, connection type, output signal, power supply, installation environment, and communication method if remote monitoring is required.

Yes. ADDA can provide customized solutions based on measuring range, process connection, wetted material, display type, communication protocol, installation method, and working environment.

Many ADDA instruments are available with explosion-proof or intrinsically safe configurations. Please confirm the site classification and certification requirements before selection.

Yes. Our team can help recommend a suitable instrument configuration after reviewing your application conditions, including medium, range, connection, output signal, and installation requirements.

Lead time depends on product type, quantity, customization requirements, and certification needs. Standard products usually have a shorter delivery time, while customized models may require additional production time.

Contact Us for Cooperation

官网询盘