Produits

Débitmètre à engrenages ovales ADDA-FL-TY

Catégorie

Débitmètre à engrenages ovales ADDA-FL-TY

Positive displacement flow meter for clean liquids, oils, fuels and viscous media. Available in DN10–DN200 with LCD display, 0.5% accuracy (0.2% optional), and pulse, 4–20 mA or Modbus RTU RS485 output options.

Certifications de qualification faisant autorité

Nous détenons la certification de qualité ISO, la qualification nationale d'entreprise de haute technologie, l'approbation de type d'instrument de mesure de Chine, et les certifications antidéflagrantes et de sécurité pour soutenir la qualité fiable des produits.

Ingénierie personnalisée

Matériaux configurables, connexions, signaux, écrans et solutions d'installation pour différents environnements de processus.

Présentation du produit

The ADDA-FL-TY Oval Gear Flow Meter is a positive displacement meter for measuring liquids in a completely filled pipe. A pair of intermeshing oval gears divides the liquid into fixed volumes. The number of gear rotations is used to determine the volume passing through the meter.

It is suitable for oil and fuel metering, as well as clean liquids such as lubricating oil, resins, adhesives and syrups. The meter configuration, wetted materials and seals must be selected for the liquid, viscosity, pressure and temperature of the application.

Caractéristiques clés

  • Positive displacement measurement for a wide range of liquid viscosities.
  • 0.5% accuracy, with a 0.2% option.
  • No upstream or downstream straight pipe run required.
  • LCD indication with pulse, 4–20 mA and RS485 output options.
  • Standard, high-temperature, high-viscosity and jacketed configurations available.
  • Simple, established mechanical construction with good repeatability.
  • Typical turndown ratio of 10:1; the applicable range depends on viscosity and configuration.
  • Relatively low pressure loss; actual pressure drop depends on the fluid and operating flow.

Principe d'exploitation

The pressure difference between the inlet and outlet (ΔP = P₁ − P₂) drives a pair of intermeshing oval gears in the measuring chamber. The gears, housing and cover form crescent-shaped measuring cavities. As the gears rotate, they carry fixed volumes of liquid from the inlet to the outlet.

The two gears alternately act as the driving and driven gear. Each quarter-turn displaces one cavity volume; one full revolution displaces four cavity volumes. Gear rotation is transmitted to the counting mechanism through a magnetic coupling or sealed coupling.

Totalized volume: V = 4 × u₀ × n, where u₀ is the volume of one crescent-shaped cavity and n is the total number of gear revolutions.

Oval gear flow meter gear positions through a measurement cycle

Four stages of oval gear rotation. Click the diagram to view the full-size image.

Spécifications techniques

ParamètreSpécification
ModèleADDA-FL-TY
Measuring principlePositive displacement with oval gears
Nominal diameterDN10–DN200
Précision±0.5% F.S.; ±0.2% F.S. optional
Pression nominale1.0–6.3 MPa, depending on configuration
Medium temperatureStandard LCD version: −20 to +60°C; high-temperature LCD version: −20 to +150°C
Matériel304 or 316L stainless steel; seal materials selected to suit the medium
Alimentation électrique24 V DC or 3.6 V lithium battery, depending on configuration
Options de sortiePulse, 4–20 mA, Modbus RTU over RS485
AffichageAffichage numérique LCD
Protection contre les ingressesIP66

Pressure rating, temperature limit, power supply and outputs depend on the selected configuration. Confirm material and seal compatibility before ordering.

Plages de flux

Select the flow range using the nominal diameter, liquid viscosity and required accuracy. All flow values below are in m³/h; viscosity values are in mPa·s. A dash means the catalogue does not specify a range for that combination.

Liquid viscosity: 0.6–2 mPa·s

TailleFlow at 0.5% accuracy (m³/h)Flow at 0.2% accuracy (m³/h)
DN100.2–0.4—
DN150.6–1.5—
DN200.8–31.5–3
DN251.2–63–6
DN405–158–15
DN506–2412–24
DN6510–4020–40
DN8010–4020–40
DN10030–10040–100
DN15045–19090–190
DN20068–340170–340

Liquid viscosity: 2–200 mPa·s

TailleFlow at 0.5% accuracy (m³/h)Flow at 0.2% accuracy (m³/h)
DN100.08–0.40.2–0.4
DN150.3–1.50.5–1.5
DN200.6–31–3
DN250.8–61.2–6
DN403–155–15
DN504–248–24
DN658–4010–40
DN808–4010–40
DN10015–10020–100
DN15034–19056–190
DN20056–34068–340

Liquid viscosity: 200–1000 mPa·s

TailleFlow at 0.5% accuracy (m³/h)Flow at 0.2% accuracy (m³/h)
DN100.04–0.30.08–0.3
DN150.2–1.00.3–1.0
DN200.4–2.10.6–2.1
DN250.6–4.21–4.2
DN402.1–10.53–10.5
DN502.4–16.84–16.8
DN656–288–28
DN806–288–28
DN10010–7015–70
DN15027–13334–133
DN20048–23856–238

Liquid viscosity: 1000–2000 mPa·s

TailleFlow at 0.5% accuracy (m³/h)Flow at 0.2% accuracy (m³/h)
DN100.03–0.20.06–0.2
DN150.1–0.70.2–0.7
DN200.25–1.50.5–1.5
DN250.6–30.8–3
DN401.0–7.52–7.5
DN502–123–12
DN654–206–20
DN804–206–20
DN10010–5012–50
DN15019–9530–95
DN20034–17050–170

Applications and Media

Applications include petroleum and petrochemical processing, chemicals, environmental protection, marine systems, metallurgy, power generation, transportation, food processing, pharmaceuticals, defense and research.

Typical media include clean oils and petroleum products, diesel, lubricating oils, adhesives, emulsions, asphalt, resins and syrups. Some acidic or alkaline liquids can be measured with compatible materials and seals. Select the meter for the actual medium and operating conditions; application suitability does not imply a particular hygienic or industry certification.

Sélection du modèle

Base model: ADDA-FL-TY. The following codes identify available configuration options; confirm the complete model combination before ordering. Power supply and signal compatibility depend on the selected configuration.

ArticleCodeOption
Product seriesGWHigh-temperature version
Product seriesGNHigh-viscosity version
Product seriesJTJacketed version
Nominal diameterDN10–DN200Specify the required nominal diameter
Pression nominalePN10PNA63Specify the flange standard and sealing face when ordering
Matériel4Acier inoxydable 304
Matériel6Acier inoxydable 316L
Output signalAPouls + 440 mA
Output signalBPouls à trois fils
Output signalCDeux fils 420 mA
Output signalDThree-wire 4–20 mA
Output signalEImpulsion + 4 MAP + Modbus RTU RS485
Output signalFPulse + 4 MAP + Modbus RTU RS485, avec HART
Connexion électriqueSM20×1,5, PVC
Connexion électriqueMM20×1,5, SUS304
Connexion électriqueN1/2 TNP, SUS304
Précision1±0,5% FS.
Précision2±0,2% FS.
Protection contre les explosionsNNon-explosion-proof version
Protection contre les explosionsDFlameproof option: Ex db IIC T6 Gb

The standard version is identified as GC in the flow-range table. Explosion protection is an optional configuration, not a rating shared by every version. Confirm the marking and documentation for the instrument supplied.

Dimensions

All linear dimensions below are in millimetres (mm). N is the number of bolt holes and Ø is the bolt-hole diameter. Click each drawing to view its full-size image.

DN10 to DN50 and DN65 DN80

ADDA-FL-TY dimensional drawing for DN10 to DN50 and DN65 DN80 oval gear flow meters

DN100

ADDA-FL-TY DN100 oval gear flow meter dimensional drawing with L H B C I D D1 and bolt hole references

DN150 and DN200

ADDA-FL-TY dimensional drawing for DN150 and DN200 oval gear flow meters

Overall Dimensions

DNLHBCI
1017010021814045
1520012023816048
2023015024316558
2526018224616864
4026518228220477
5026518229121392
65350255380275125
80350255380275125
100515418468338131
150540510557377210
200650650624436247

Flange and Bolt Dimensions

DNDD1NØ
109060414
159565414
2010575414
2511585414
40150110418
50165125418
65185145418
80200160818
100220180818
150285240823
2003402951223

Flange basis: Flange dimensions are based on a pressure rating of 1.6 MPa. Overall length and flange dimensions can be customized.

High-temperature version: For DN15–DN50, add 100 mm to dimension B for the thermal extension tube. This allowance does not apply to the other sizes listed above.

Selection and Ordering

Provide the liquid name, viscosity at operating temperature, minimum and maximum flow, pipe diameter, operating pressure and temperature, flange standard, preferred power supply and required output. The high-viscosity and high-temperature versions should be selected for the corresponding service conditions. Confirm the applicable configuration with ADDA before ordering.

Produits connexes

Vitrine

Foire aux questions

Trouvez des réponses rapides sur la sélection des produits, la personnalisation, les paramètres techniques, la livraison et le support des instruments de mesure industriels ADDA.

官网询盘

Veuillez fournir le support mesuré, la plage de mesure, la température du processus, la pression du processus, le type de connexion, le signal de sortie, l'alimentation électrique, l'environnement d'installation et la méthode de communication si une surveillance à distance est requise.

Oui. ADDA peut fournir des solutions personnalisées basées sur la plage de mesure, la connexion au processus, le matériau mouillé, le type d'affichage, le protocole de communication, la méthode d'installation et l'environnement de travail.

De nombreux instruments ADDA sont disponibles avec des configurations antidéflagrantes ou intrinsèquement sûres Veuillez confirmer les exigences de classification et de certification du site avant la sélection.

Oui. Notre équipe peut vous aider à recommander une configuration d'instrument appropriée après avoir examiné vos conditions d'application, notamment le support, la portée, la connexion, le signal de sortie et les exigences d'installation.

Le délai d'exécution dépend du type de produit, de la quantité, des exigences de personnalisation et des besoins de certification Les produits standard ont généralement un délai de livraison plus court, tandis que les modèles personnalisés peuvent nécessiter un délai de production supplémentaire.

Contactez-nous pour la coopération

官网询盘