Compact Temperature Transmitter

The ADDA-T-JQ compact temperature transmitter measures the temperature of solid surfaces, liquids, and gases. Its sealed design resists vibration and moisture, and its two-wire current output supports industrial temperature monitoring.

Authoritative Qualification Certifications

We hold ISO quality certification, national high-tech enterprise qualification, China measuring instrument type approval, and explosion-proof and safety certifications to support reliable product quality.

Custom Engineering

Configurable materials, connections, signals, displays, and installation solutions for different process environments.

Product Features                                                      

The ADDA-T-JQ Series RTD temperature transmitter measures and transmits the temperature of solid surfaces, liquids, and gases. Key features include:

  • Sealed with silicone rubber or epoxy resin for vibration and moisture resistance.
  • High accuracy, low quiescent power consumption, stable and reliable operation, and long service life.
  • Two-wire 4mA.dc.~20mA.dc output with strong interference resistance and long transmission distance.

Applications

Temperature measurement in petroleum, chemical, metallurgical, electric power, and other industries.

Measuring Medium

Media compatible with the wetted materials.

Performance Specifications

Accuracy±0.1%, ±0.2%, 0.5% Upper Range Limit,  see specifications for details
Range-200~600 degrees C, see selection table for details
Annual Stability±0.1% Span/2 years
Voltage InfluenceWhen the supply voltage varies within 10.5V/16.5V~36V DC, the changes in zero point and span shall not exceed ±0.001%URL/V
Output Signal4mA~20mADC
Protection GradeIP65/IP67

Range

Sensor TypeMeasuring Range degrees CMinimum Measurable Range degrees CMeasurement Accuracy (whichever is greater) degrees C
Pt100-200~60050±0.2% range or ±0.2
Pt1000-200~35050±0.2% range or ±0.2

Environmental Conditions

ItemCondition
Operating Ambient Temperature Range-40 degrees C ~ 85 degrees C
Storage Ambient Temperature Range-40 degrees C ~ 100 degrees C
Operating Ambient Humidity Range5%RH~100%RH@40 degrees C

Power Supply and Load Conditions

ItemOperating Condition
Power Supply Voltage4mA~20mA: 10.5V~36V DC
Load Resistance0Ω~600Ω
Transmission Distance< 1000m
Power Consumption
4mA~20mA<= 500mW@24V DC, 20.8mA

Related Products

Case Showcase

Frequently Asked Questions

Find quick answers about product selection, customization, technical parameters, delivery, and support for ADDA industrial measurement instruments.

官网询盘

Please provide the measured medium, measuring range, process temperature, process pressure, connection type, output signal, power supply, installation environment, and communication method if remote monitoring is required.

Yes. ADDA can provide customized solutions based on measuring range, process connection, wetted material, display type, communication protocol, installation method, and working environment.

Many ADDA instruments are available with explosion-proof or intrinsically safe configurations. Please confirm the site classification and certification requirements before selection.

Yes. Our team can help recommend a suitable instrument configuration after reviewing your application conditions, including medium, range, connection, output signal, and installation requirements.

Lead time depends on product type, quantity, customization requirements, and certification needs. Standard products usually have a shorter delivery time, while customized models may require additional production time.

Contact Us for Cooperation

官网询盘