{"id":4062,"date":"2026-10-14T01:48:04","date_gmt":"2026-10-14T01:48:04","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-yl-rotary-lobe-flow-meter\/"},"modified":"2026-10-21T03:59:23","modified_gmt":"2026-10-21T03:59:23","slug":"adda-fl-yl-rotary-lobe-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/ru\/product\/adda-fl-yl-rotary-lobe-flow-meter\/","title":{"rendered":"\u0420\u0430\u0441\u0445\u043e\u0434\u043e\u043c\u0435\u0440 \u0441 \u0432\u0440\u0430\u0449\u0430\u044e\u0449\u0438\u043c\u0438\u0441\u044f \u043b\u0435\u043f\u0435\u0441\u0442\u043a\u0430\u043c\u0438 ADDA-FL-YL"},"content":{"rendered":"<p><a href=\"#overview\">\u041e\u0431\u0437\u043e\u0440<\/a> | <a href=\"#specifications\">\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438<\/a> | <a href=\"#liquid-flow-ranges-by-viscosity\">\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u044b \u043f\u043e\u0442\u043e\u043a\u043e\u0432<\/a> | <a href=\"#dimensions\">\u0420\u0430\u0437\u043c\u0435\u0440\u044b<\/a><\/p>\n<h2 id=\"overview\">\u041e\u0431\u0437\u043e\u0440<\/h2>\n<p>The ADDA-FL-YL rotary lobe flow meter, also known as a Roots flow meter, measures volume by positive displacement. A pair of figure-eight rotors turns under the pressure difference across the meter. Each revolution displaces a fixed volume, and the rotation signal is used to calculate the total volume passing through the meter.<\/p>\n<p>The liquid version is suitable for clean liquids without hard particles, including oils and viscous media. The specifications and flow tables below apply to the liquid series. For gas service, contact us to confirm the appropriate configuration, measurement range and operating conditions.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4022\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main.webp\" alt=\"Catalogue product illustration for the ADDA-FL-YL rotary lobe flow meter\" width=\"800\" height=\"800\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main.webp 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-300x300.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-150x150.webp 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-768x768.webp 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-12x12.webp 12w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-600x600.webp 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-flow-meter-main-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption>ADDA-FL-YL catalogue product illustration.<\/figcaption><\/figure>\n<h2 id=\"features\">\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438<\/h2>\n<ul>\n<li>Positive displacement measurement with 0.5% accuracy and optional 0.2% accuracy.<\/li>\n<li>A broad measuring range with stable metering at the specified low-flow limits.<\/li>\n<li>Suitable for oils and viscous liquids within the stated viscosity ranges.<\/li>\n<li>Minimal straight-pipe requirements upstream and downstream.<\/li>\n<li>Selectable electrical outputs and optional high-temperature or jacketed configurations.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">\u041f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b<\/h2>\n<p>Two symmetrical figure-eight rotors are mounted with a small, non-contact clearance in the measuring chamber. The pressure difference between the inlet and outlet rotates the pair. The rotors, housing and partitions enclose measuring pockets that carry liquid through the meter. Each revolution transfers four fixed chamber volumes. A magnetic coupling detects rotation and produces pulses for flow measurement and totalization.<\/p>\n<p>V0 = 4 \u00d7 Vc, where V0 is the displaced volume per rotor revolution, expressed in m\u00b3\/rev or L\/rev, and Vc is the volume of one measuring chamber.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image146.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4048\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image146.webp\" alt=\"Rotary lobe flow meter rotor positions through a measurement cycle\" width=\"554\" height=\"217\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image146.webp 554w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image146-300x118.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image146-18x7.webp 18w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/><\/a><figcaption>Rotary-lobe measuring cycle.<\/figcaption><\/figure>\n<h2 id=\"specifications\">Liquid Series Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th scope=\"col\">\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Measured media<\/td>\n<td>Clean liquids without impurities, including diesel, gasoline, methanol, ethanol, distilled spirits, petroleum products, and compatible acid or alkaline liquids<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/td>\n<td>DN25\u2013DN150<\/td>\n<\/tr>\n<tr>\n<td>\u0417\u0430\u0449\u0438\u0442\u0430 \u0432\u0445\u043e\u0434\u0430<\/td>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<td>Materials<\/td>\n<td>SUS304 or SUS316L stainless steel<\/td>\n<\/tr>\n<tr>\n<td>\u041f\u0438\u0442\u0430\u043d\u0438\u0435<\/td>\n<td>24 V DC or 3.6 V lithium battery, depending on the configuration<\/td>\n<\/tr>\n<tr>\n<td>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u0432\u044b\u0432\u043e\u0434\u0430<\/td>\n<td>4\u201320 mA, Modbus RTU RS485 and pulse; HART available with output option F<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0435\u0439\u0442\u0438\u043d\u0433 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/td>\n<td>1.0\u20136.3 MPa; select the ordered pressure class<\/td>\n<\/tr>\n<tr>\n<td>Standard LCD version temperature range<\/td>\n<td>-20\u00b0C to +80\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>High-temperature LCD version temperature range<\/td>\n<td>-20\u00b0C to +120\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u0438\u0441\u043f\u043b\u0435\u0439<\/td>\n<td>\u0416\u041a-\u0446\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0434\u0438\u0441\u043f\u043b\u0435\u0439<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>0.5%; 0.2% optional. See the ordering accuracy codes.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"liquid-flow-ranges-by-viscosity\">Liquid Flow Ranges by Viscosity<\/h2>\n<p>Select the nominal size and accuracy for the viscosity at operating temperature. The following liquid flow ranges are in m\u00b3\/h and must not be applied to gas service.<\/p>\n<table>\n<caption>Viscosity 0.6\u20133 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>1.2~6<\/td>\n<td>2~6<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>3.2~16<\/td>\n<td>5~16<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>5~25<\/td>\n<td>8~25<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>12~60<\/td>\n<td>20~60<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>20~100<\/td>\n<td>33~100<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>50~250<\/td>\n<td>80~250<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Viscosity 3\u2013150 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>0.6~6<\/td>\n<td>1.5~6<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>1.6~16<\/td>\n<td>6~16<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>2.5~25<\/td>\n<td>6~25<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>6~60<\/td>\n<td>15~60<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>10~100<\/td>\n<td>25~100<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>25~250<\/td>\n<td>60~250<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"applications\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p>Petroleum, chemical processing, environmental protection, marine, metallurgy, power generation, transportation, food, pharmaceutical, defense and research applications. Confirm the wetted materials and configuration for the intended process.<\/p>\n<h2 id=\"model-selection\">\u0412\u044b\u0431\u043e\u0440 \u043c\u043e\u0434\u0435\u043b\u0438<\/h2>\n<p>Base model: ADDA-FL-YL. Select the required options below.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Selection<\/th>\n<th scope=\"col\">\u041a\u043e\u0434<\/th>\n<th scope=\"col\">\u041e\u043f\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series<\/td>\n<td>\u0413\u0412\u0422<\/td>\n<td>High-temperature type<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>\u0414\u0416\u0415\u0419\u0422\u0418<\/td>\n<td>Jacketed type<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/td>\n<td>DN25\u2013DN150<\/td>\n<td>Select the size for the required flow and viscosity.<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0435\u0439\u0442\u0438\u043d\u0433 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/td>\n<td>PN10 \u2014 PN63<\/td>\n<td>State the flange standard and sealing face when ordering.<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b<\/td>\n<td>4<\/td>\n<td>304 \u043d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b<\/td>\n<td>6<\/td>\n<td>316L \u043d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>A<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 420 \u043c\u0410<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>B<\/td>\n<td>\u0422\u0440\u0435\u0445\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0439 \u0438\u043c\u043f\u0443\u043b\u044c\u0441<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>C<\/td>\n<td>\u0414\u0432\u0443\u0445\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u044b\u0439 420 \u043c\u0410<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>E<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 4 \u2014 20 \u043c\u0410 + Modbus RTU RS485<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>F<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 4 \u2014 20 \u043c\u0410 + Modbus RTU RS485, \u0441 HART + 40 \u043c\u0410 + Modbus RTU<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>S<\/td>\n<td>\u041c20 \u00d7 1,5, \u041f\u0412\u0425<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>M<\/td>\n<td>\u041c20 \u00d7 1,5, \u0421\u0423\u0421304<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>N<\/td>\n<td>1\/2 \u0414\u041d\u042f\u041e, SUS304<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>1<\/td>\n<td>\u00b10,5% \u0424\u0421.<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>2<\/td>\n<td>\u00b10,2% \u0424\u0421.<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0442\u0430<\/td>\n<td>N<\/td>\n<td>Non-explosion-proof configuration<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0442\u0430<\/td>\n<td>D<\/td>\n<td>Optional flameproof configuration, Ex db IIC T6 Gb; confirm on request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Specify the required wetted materials when ordering.<\/p>\n<p>Explosion protection is an order option, not a standard feature of every meter. Confirm the selected Ex marking, applicable approval documents and operating conditions before ordering.<\/p>\n<h2 id=\"dimensions\">\u0420\u0430\u0437\u043c\u0435\u0440\u044b<\/h2>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4049\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147.webp\" alt=\"Rotary lobe flow meter chamber and flange dimensional drawing\" width=\"649\" height=\"474\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147.webp 649w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147-300x219.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147-16x12.webp 16w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image147-600x438.webp 600w\" sizes=\"(max-width: 649px) 100vw, 649px\" \/><\/a><figcaption>ADDA-FL-YL front-view dimension references.<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image148.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4050\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image148.webp\" alt=\"Rotary lobe flow meter inlet and outlet flange dimensional view\" width=\"548\" height=\"463\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image148.webp 548w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image148-300x253.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-yl-image148-14x12.webp 14w\" sizes=\"(max-width: 548px) 100vw, 548px\" \/><\/a><figcaption>ADDA-FL-YL end-view dimension references.<\/figcaption><\/figure>\n<table>\n<caption>Body dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">H (mm)<\/th>\n<th scope=\"col\">B (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>260<\/td>\n<td>271<\/td>\n<td>160<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>265<\/td>\n<td>296<\/td>\n<td>160<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>265<\/td>\n<td>316<\/td>\n<td>185<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>320<\/td>\n<td>400<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>400<\/td>\n<td>420<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>560<\/td>\n<td>557<\/td>\n<td>525<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Body dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">C (mm)<\/th>\n<th scope=\"col\">I (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>195<\/td>\n<td>77<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>220<\/td>\n<td>94<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>250<\/td>\n<td>113<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>316<\/td>\n<td>147<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>337<\/td>\n<td>170<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>377<\/td>\n<td>210<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Flange dimensions<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<th scope=\"col\">D1 (mm)<\/th>\n<th scope=\"col\">N<\/th>\n<th scope=\"col\">Hole diameter (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>115<\/td>\n<td>85<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>150<\/td>\n<td>110<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>165<\/td>\n<td>125<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>200<\/td>\n<td>160<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>220<\/td>\n<td>180<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>285<\/td>\n<td>240<\/td>\n<td>8<\/td>\n<td>23<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Confirm the final flange specification and installation drawing for the ordered configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0412 ADDA-FL-YL \u0440\u043e\u0442\u043e\u0440\u043d\u044b\u0439 \u043b\u0435\u043f\u0435\u0441\u0442\u043e\u043a, \u0438\u043b\u0438 \u041a\u043e\u0440\u043d\u0438, \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u043c\u0435\u0440 \u0438\u0437\u043c\u0435\u0440\u0435\u043d\u0438\u044f \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u0441\u043c\u0435\u0449\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0447\u0438\u0441\u0442\u044b\u0445 \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0435\u0439, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u043c\u0430\u0441\u043b\u0430 \u0438 \u0432\u044f\u0437\u043a\u0438\u0435 \u0441\u0440\u0435\u0434\u044b.DN25DN150 \u0436\u0438\u0434\u043a\u043e\u0439 \u0441\u0435\u0440\u0438\u0438 \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 LCD \u0438\u043d\u0434\u0438\u043a\u0430\u0446\u0438\u044e, \u043e\u043f\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e 0.2% \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u044c, \u0438 \u0432\u044b\u0431\u0438\u0440\u0430\u0435\u043c\u044b\u0439 \u0438\u043c\u043f\u0443\u043b\u044c\u0441, 420 \u043c\u0410, \u041c\u043e\u0434\u0431\u0443\u0441 RTU RS485 \u0438 HART \u0432\u044b\u0445\u043e\u0434\u044b.<\/p>","protected":false},"featured_media":4022,"template":"","meta":{"rank_math_title":"ADDA-FL-YL Rotary Lobe Flow Meter | Liquid Totalizing","rank_math_description":"The ADDA-FL-YL rotary lobe flow meter uses positive displacement for clean liquids, including oils and viscous media within its stated ranges.","rank_math_canonical_url":"","rank_math_focus_keyword":"Rotary Lobe Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4062","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product\/4062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/media\/4022"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/media?parent=4062"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_brand?post=4062"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_cat?post=4062"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_tag?post=4062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}