{"id":4061,"date":"2026-10-14T01:48:04","date_gmt":"2026-10-14T01:48:04","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-lx-helical-twin-rotor-flow-meter\/"},"modified":"2026-10-21T03:59:23","modified_gmt":"2026-10-21T03:59:23","slug":"adda-fl-lx-helical-twin-rotor-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/ru\/product\/adda-fl-lx-helical-twin-rotor-flow-meter\/","title":{"rendered":"\u0421\u043f\u0438\u0440\u0430\u043b\u044c\u043d\u044b\u0439 \u0434\u0432\u0443\u0445\u0440\u043e\u0442\u043e\u0440\u043d\u044b\u0439 \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u043c\u0435\u0440 ADDA-FL-LX"},"content":{"rendered":"<p><a href=\"#overview\">\u041e\u0431\u0437\u043e\u0440<\/a> | <a href=\"#specifications\">\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438<\/a> | <a href=\"#flow-ranges-by-viscosity\">\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u044b \u043f\u043e\u0442\u043e\u043a\u043e\u0432<\/a> | <a href=\"#dimensions\">\u0420\u0430\u0437\u043c\u0435\u0440\u044b<\/a><\/p>\n<h2 id=\"overview\">\u041e\u0431\u0437\u043e\u0440<\/h2>\n<p>The ADDA-FL-LX is a positive displacement flow meter with two helical rotors. Liquid pressure drives the rotors and transfers measured volumes through enclosed chambers. Counting rotor revolutions provides total volume and instantaneous flow. The design supports smooth liquid delivery over a wide viscosity range and does not require a developed flow profile.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4021\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main.webp\" alt=\"Catalogue product illustration for the ADDA-FL-LX helical twin rotor flow meter\" width=\"800\" height=\"800\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main.webp 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-300x300.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-150x150.webp 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-768x768.webp 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-12x12.webp 12w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-600x600.webp 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-flow-meter-main-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption>ADDA-FL-LX catalogue product illustration.<\/figcaption><\/figure>\n<h2 id=\"features\">\u041e\u0441\u043e\u0431\u0435\u043d\u043d\u043e\u0441\u0442\u0438<\/h2>\n<ul>\n<li>Smooth operation with low noise and a design intended to avoid flow pulsation during continuous high-flow service.<\/li>\n<li>High flow capacity for the nominal size with low pressure loss.<\/li>\n<li>Accuracy of 0.5%, with 0.2% available as an option.<\/li>\n<li>Standard and high-viscosity variants covering the viscosity bands listed in the flow tables.<\/li>\n<li>Non-contact rotors reduce wear; confirm compatibility for the actual process liquid.<\/li>\n<li>No upstream or downstream straight-pipe section is required.<\/li>\n<li>High-temperature and jacketed configurations are available for suitable processes.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">\u041f\u0440\u0438\u043d\u0446\u0438\u043f \u0440\u0430\u0431\u043e\u0442\u044b<\/h2>\n<p>A pair of specially shaped 45\u00b0 helical rotors is installed in the measuring chamber. The inlet-to-outlet pressure difference drives the rotors, while the rotor surfaces and housing enclose fixed-volume pockets. Each revolution transfers eight chamber volumes from the inlet to the outlet. Magnetic or photoelectric sensing converts rotor motion into total volume and instantaneous flow rate.<\/p>\n<p>V = 8 \u00d7 V0 \u00d7 n, where V is total measured volume, V0 is the volume of one measuring chamber and n is the number of rotor revolutions.<\/p>\n<h2 id=\"specifications\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th scope=\"col\">\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Measured media<\/td>\n<td>Clean liquids compatible with the selected materials, including oil, petroleum products, diesel, adhesives, emulsions, bitumen, resins, and acid or alkaline liquids<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/td>\n<td>DN25\u2013DN300<\/td>\n<\/tr>\n<tr>\n<td>\u0417\u0430\u0449\u0438\u0442\u0430 \u0432\u0445\u043e\u0434\u0430<\/td>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<td>Materials<\/td>\n<td>SUS304 or SUS316L stainless steel<\/td>\n<\/tr>\n<tr>\n<td>\u041f\u0438\u0442\u0430\u043d\u0438\u0435<\/td>\n<td>24 V DC or 3.6 V lithium battery, depending on the configuration<\/td>\n<\/tr>\n<tr>\n<td>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u0432\u044b\u0432\u043e\u0434\u0430<\/td>\n<td>4\u201320 mA, Modbus RTU RS485 and pulse; HART available with output option F<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0435\u0439\u0442\u0438\u043d\u0433 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/td>\n<td>1.0\u20136.3 MPa; select the ordered pressure class<\/td>\n<\/tr>\n<tr>\n<td>Standard LCD version temperature range<\/td>\n<td>-20\u00b0C to +80\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>High-temperature LCD version temperature range<\/td>\n<td>-20\u00b0C to +300\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u0438\u0441\u043f\u043b\u0435\u0439<\/td>\n<td>\u0416\u041a-\u0446\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0434\u0438\u0441\u043f\u043b\u0435\u0439<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>0.5%; 0.2% optional. See the ordering accuracy codes.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"flow-ranges-by-viscosity\">Flow Ranges by Viscosity<\/h2>\n<p>Choose the nominal size, accuracy and variant using the viscosity at the operating temperature. All flow ranges below are in m\u00b3\/h.<\/p>\n<table>\n<caption>GC standard type, viscosity 0.6\u20132 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>3~10<\/td>\n<td>3.5~8<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>7~20<\/td>\n<td>8~20<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>9~36<\/td>\n<td>15~36<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>20~80<\/td>\n<td>30~80<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>25~100<\/td>\n<td>40~100<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>22~225<\/td>\n<td>88~220<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d200<\/td>\n<td>90~360<\/td>\n<td>150~360<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d250<\/td>\n<td>130~540<\/td>\n<td>180~540<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d300<\/td>\n<td>220~800<\/td>\n<td>250~800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>GC standard type, viscosity 2\u2013400 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>2~10<\/td>\n<td>2~10<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>2.5~25<\/td>\n<td>2.5~25<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>3.6~36<\/td>\n<td>3.6~36<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>10~100<\/td>\n<td>10~100<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>15~150<\/td>\n<td>15~150<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>25~250<\/td>\n<td>25~250<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d200<\/td>\n<td>60~420<\/td>\n<td>60~420<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d250<\/td>\n<td>80~600<\/td>\n<td>80~600<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d300<\/td>\n<td>95~950<\/td>\n<td>95~950<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>GN high-viscosity type, viscosity 400\u20132000 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>2~8<\/td>\n<td>2~8<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>2~18<\/td>\n<td>4~18<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>2.8~25<\/td>\n<td>6~25<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>6.5~56<\/td>\n<td>14~56<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>8.5~80<\/td>\n<td>18~72<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>18~150<\/td>\n<td>38~150<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d200<\/td>\n<td>28~240<\/td>\n<td>50~210<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d250<\/td>\n<td>42~360<\/td>\n<td>90~360<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d300<\/td>\n<td>70~600<\/td>\n<td>150~600<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>GN high-viscosity type, viscosity 2000\u20133500 mPa\u00b7s<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/th>\n<th scope=\"col\">0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0414\u041d25<\/td>\n<td>2~6<\/td>\n<td>2~6<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d40<\/td>\n<td>3~12<\/td>\n<td>3~12<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d50<\/td>\n<td>4.5~18<\/td>\n<td>4.5~18<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d80<\/td>\n<td>5~40<\/td>\n<td>10~40<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d100<\/td>\n<td>6.5~55<\/td>\n<td>14~55<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d150<\/td>\n<td>10~100<\/td>\n<td>25~100<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d200<\/td>\n<td>20~160<\/td>\n<td>40~160<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d250<\/td>\n<td>30~240<\/td>\n<td>60~240<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u041d300<\/td>\n<td>54~450<\/td>\n<td>110~450<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"applications\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p>Petroleum, chemical processing, environmental protection, marine, metallurgy, power generation, transportation, food, pharmaceutical, defense and research applications. Confirm the wetted materials and configuration for the intended process.<\/p>\n<h2 id=\"model-selection\">\u0412\u044b\u0431\u043e\u0440 \u043c\u043e\u0434\u0435\u043b\u0438<\/h2>\n<p>Base model: ADDA-FL-LX. Select the required options below.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Selection<\/th>\n<th scope=\"col\">\u041a\u043e\u0434<\/th>\n<th scope=\"col\">\u041e\u043f\u0446\u0438\u044f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series<\/td>\n<td>\u0413\u0412\u0422<\/td>\n<td>High-temperature type<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>\u0413\u041d<\/td>\n<td>High-viscosity type<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>\u0414\u0416\u0415\u0419\u0422\u0418<\/td>\n<td>Jacketed type<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0440\u0430\u0437\u043c\u0435\u0440<\/td>\n<td>DN25\u2013DN300<\/td>\n<td>Select the size for the required flow and viscosity.<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0435\u0439\u0442\u0438\u043d\u0433 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/td>\n<td>PN10 \u2014 PN63<\/td>\n<td>State the flange standard and sealing face when ordering.<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b<\/td>\n<td>4<\/td>\n<td>304 \u043d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b<\/td>\n<td>6<\/td>\n<td>316L \u043d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>A<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 420 \u043c\u0410<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>B<\/td>\n<td>\u0422\u0440\u0435\u0445\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0439 \u0438\u043c\u043f\u0443\u043b\u044c\u0441<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>C<\/td>\n<td>\u0414\u0432\u0443\u0445\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u044b\u0439 420 \u043c\u0410<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>E<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 4 \u2014 20 \u043c\u0410 + Modbus RTU RS485<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>F<\/td>\n<td>\u0418\u043c\u043f\u0443\u043b\u044c\u0441 + 4 \u2014 20 \u043c\u0410 + Modbus RTU RS485, \u0441 HART + 40 \u043c\u0410 + Modbus RTU<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>S<\/td>\n<td>\u041c20 \u00d7 1,5, \u041f\u0412\u0425<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>M<\/td>\n<td>\u041c20 \u00d7 1,5, \u0421\u0423\u0421304<\/td>\n<\/tr>\n<tr>\n<td>\u042d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u0435<\/td>\n<td>N<\/td>\n<td>1\/2 \u0414\u041d\u042f\u041e, SUS304<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>1<\/td>\n<td>\u00b10,5% \u0424\u0421.<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u043e\u0447\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>2<\/td>\n<td>\u00b10,2% \u0424\u0421.<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0442\u0430<\/td>\n<td>N<\/td>\n<td>Non-explosion-proof configuration<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0437\u0440\u044b\u0432\u043e\u0437\u0430\u0449\u0438\u0442\u0430<\/td>\n<td>D<\/td>\n<td>Optional flameproof configuration, Ex db IIC T6 Gb; confirm on request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Specify the required wetted materials when ordering.<\/p>\n<p>Explosion protection is an order option, not a standard feature of every meter. Confirm the selected Ex marking, applicable approval documents and operating conditions before ordering.<\/p>\n<h2 id=\"dimensions\">\u0420\u0430\u0437\u043c\u0435\u0440\u044b<\/h2>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4047\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145.webp\" alt=\"Helical twin rotor flow meter sectional and flange dimensions\" width=\"525\" height=\"528\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145.webp 525w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145-298x300.webp 298w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145-150x150.webp 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145-12x12.webp 12w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-lx-image145-100x100.webp 100w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><\/a><figcaption>Body and flange dimension references for the ADDA-FL-LX series.<\/figcaption><\/figure>\n<table>\n<caption>Body dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">H (mm)<\/th>\n<th scope=\"col\">B (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>300<\/td>\n<td>378<\/td>\n<td>175<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>300<\/td>\n<td>414<\/td>\n<td>185<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>340<\/td>\n<td>480<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>380<\/td>\n<td>533<\/td>\n<td>280<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>440<\/td>\n<td>584<\/td>\n<td>320<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>540<\/td>\n<td>683<\/td>\n<td>410<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>640<\/td>\n<td>757<\/td>\n<td>455<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>700<\/td>\n<td>844<\/td>\n<td>550<\/td>\n<\/tr>\n<tr>\n<td>300<\/td>\n<td>800<\/td>\n<td>994<\/td>\n<td>645<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Body dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">C (mm)<\/th>\n<th scope=\"col\">I (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>218<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>254<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>307<\/td>\n<td>126<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>360<\/td>\n<td>156<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>411<\/td>\n<td>184<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>510<\/td>\n<td>226<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>584<\/td>\n<td>265<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>671<\/td>\n<td>309<\/td>\n<\/tr>\n<tr>\n<td>300<\/td>\n<td>821<\/td>\n<td>390<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Flange dimensions<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<th scope=\"col\">D1 (mm)<\/th>\n<th scope=\"col\">N<\/th>\n<th scope=\"col\">Hole diameter (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>25<\/td>\n<td>115<\/td>\n<td>85<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>150<\/td>\n<td>110<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>165<\/td>\n<td>125<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>200<\/td>\n<td>160<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>220<\/td>\n<td>180<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>150<\/td>\n<td>285<\/td>\n<td>240<\/td>\n<td>8<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>340<\/td>\n<td>295<\/td>\n<td>12<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>405<\/td>\n<td>355<\/td>\n<td>12<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td>300<\/td>\n<td>460<\/td>\n<td>410<\/td>\n<td>12<\/td>\n<td>26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The flange dimensions shown are based on PN16. For high-temperature versions, increase H by 100 mm for DN25\u2013DN40 and by 160 mm for DN50\u2013DN300. Confirm the installation dimensions for the specified pressure class and configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>ADDA-FL-LX - \u044d\u0442\u043e \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u043c\u0435\u0440 \u0441 \u043f\u043e\u043b\u043e\u0436\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0441\u043c\u0435\u0449\u0435\u043d\u0438\u0435\u043c \u0434\u043b\u044f \u0434\u043e\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0436\u0438\u0434\u043a\u043e\u0441\u0442\u0438 \u0432 \u0448\u0438\u0440\u043e\u043a\u043e\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435 \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u0438. \u0421\u0435\u0440\u0438\u044f DN25 \u2014 DN300 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442 \u043f\u0430\u0440\u043d\u044b\u0435 \u0441\u043f\u0438\u0440\u0430\u043b\u044c\u043d\u044b\u0435 \u0440\u043e\u0442\u043e\u0440\u044b \u0438 \u043f\u0440\u0435\u0434\u043b\u0430\u0433\u0430\u0435\u0442 \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u0441 \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0432\u044f\u0437\u043a\u043e\u0441\u0442\u044c\u044e, \u0432\u044b\u0441\u043e\u043a\u043e\u0439 \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043e\u0439 \u0438 \u0440\u0443\u0431\u0430\u0448\u043a\u043e\u0439, \u0441 \u0434\u043e\u043f\u043e\u043b\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u043c, 420 \u043c\u0410, Modbus RTU RS485 \u0438 \u0432\u044b\u0445\u043e\u0434\u0430\u043c\u0438 HART.<\/p>","protected":false},"featured_media":4021,"template":"","meta":{"rank_math_title":"ADDA-FL-LX Helical Twin Rotor Flow Meter | Liquid Flow","rank_math_description":"The ADDA-FL-LX helical twin rotor flow meter measures liquid volume with non-contact rotors and offers standard and high-viscosity configurations.","rank_math_canonical_url":"","rank_math_focus_keyword":"Helical Twin Rotor Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4061","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product\/4061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/media\/4021"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/media?parent=4061"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_brand?post=4061"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_cat?post=4061"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ru\/wp-json\/wp\/v2\/product_tag?post=4061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}