{"id":4109,"date":"2026-11-02T08:00:00","date_gmt":"2026-11-02T08:00:00","guid":{"rendered":"https:\/\/www.addameter.com\/?p=4109"},"modified":"2026-11-04T02:13:15","modified_gmt":"2026-11-04T02:13:15","slug":"mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define","status":"publish","type":"post","link":"https:\/\/www.addameter.com\/pt\/mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define\/","title":{"rendered":"Transmissor de press\u00e3o MEMS: o que o chip sensor faz e n\u00e3o define"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>\u00cdndice<\/h2><nav><ul><li class=\"\"><a href=\"#mems-pressure-transmitter-measurement-basis\">Mems pressure transmitter: measurement basis<\/a><\/li><li class=\"\"><a href=\"#range-and-operating-envelope\">Alcance e envelope operacional<\/a><\/li><li class=\"\"><a href=\"#medium-and-material-review\">Revis\u00e3o m\u00e9dia e material<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-installation-details\">Mems pressure transmitter: installation details<\/a><\/li><li class=\"\"><a href=\"#signal-and-configuration\">Sinal e configura\u00e7\u00e3o<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-verification-plan\">Mems pressure transmitter: verification plan<\/a><\/li><li class=\"\"><a href=\"#maintenance-and-fault-checks\">Manuten\u00e7\u00e3o e verifica\u00e7\u00f5es de falhas<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-specification-for-adda\">Mems pressure transmitter: specification for ADDA<\/a><\/li><li class=\"\"><a href=\"#practical-review-what-the-sensing-chip-does-and-does-not-define\">Practical review: What the Sensing Chip Does and Does Not Define<\/a><\/li><li class=\"\"><a href=\"#technology-and-configuration-comparison\">Compara\u00e7\u00e3o de tecnologia e configura\u00e7\u00e3o<\/a><\/li><li class=\"\"><a href=\"#frequently-asked-questions\">Perguntas frequentes<\/a><ul><li class=\"\"><a href=\"#faq-question-12-1\">What should be confirmed first for mems pressure transmitter?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-2\">Which information does ADDA need for a mems pressure transmitter inquiry?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-3\">How should mems pressure transmitter acceptance be documented?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-4\">Can one mems pressure transmitter setting be used for every operating condition?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-5\">When should the mems pressure transmitter configuration be reviewed again?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Mems pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on what the Sensing Chip Does and Does Not Define in a silicon or MEMS pressure assembly on an OEM machine. The aim is to build an error budget around the value the process actually needs and turn that review into a configuration that can be installed, checked and maintained.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para engenheiros e equipes de compras, o ponto de partida \u00fatil \u00e9 o valor do processo que deve ser confi\u00e1vel, as condi\u00e7\u00f5es que podem torn\u00e1-lo errado e as evid\u00eancias necess\u00e1rias antes da aceita\u00e7\u00e3o A revis\u00e3o a seguir conecta o m\u00e9todo de detec\u00e7\u00e3o com o sistema f\u00edsico de instala\u00e7\u00e3o e recep\u00e7\u00e3o Exemplos num\u00e9ricos s\u00e3o c\u00e1lculos ilustrativos, enquanto os limites e op\u00e7\u00f5es finais do modelo devem ser confirmados para a montagem ordenada.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg\" alt=\"ADDA pressure instrument with local digital display\" class=\"wp-image-1152\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 id=\"mems-pressure-transmitter-measurement-basis\" class=\"wp-block-heading\">Mems pressure transmitter: measurement basis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A press\u00e3o no diafragma \u00e9 convertida em uma medi\u00e7\u00e3o el\u00e9trica e, em seguida, em uma sa\u00edda configurada Um instrumento de calibre usa a press\u00e3o atmosf\u00e9rica como refer\u00eancia Um instrumento absoluto usa uma refer\u00eancia de v\u00e1cuo selada Corresponder a essa refer\u00eancia ao c\u00e1lculo do processo \u00e9 mais consequente do que adicionar resolu\u00e7\u00e3o de exibi\u00e7\u00e3o Em um elemento piezoresistivo, a deforma\u00e7\u00e3o do diafragma altera a resist\u00eancia el\u00e9trica A compensa\u00e7\u00e3o aborda o elemento selecionado e o comportamento da montagem; ele n\u00e3o estabelece compatibilidade para o encaixe do processo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The mems pressure transmitter review should establish one consistent physical basis. Define the quantity being compared and the tolerance for acceptance. Calibration establishes the relationship to a reference under stated conditions; any adjustment should be identified separately in the work record.<\/p>\n\n\n\n<h2 id=\"range-and-operating-envelope\" class=\"wp-block-heading\">Alcance e envelope operacional<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The operating span must cover the lowest useful reading and the highest normal condition. Startup spikes, cleaning pressure and accidental isolation can impose different demands. Measuring range, allowable overload and pressure boundary rating are separate quantities; a larger electrical span cannot compensate for an inadequate mechanical rating. Review the complete calibrated assembly rather than comparing chip technology in isolation. Mechanical packaging, temperature effects and the selected range remain part of the measurement error budget.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For mems pressure transmitter, the selected endpoints need a documented operating basis. Translate each stated error into the same engineering unit before comparison. Include the low end of normal operation, where a fixed full-scale term can represent a large fraction of the actual reading.<\/p>\n\n\n\n<h2 id=\"medium-and-material-review\" class=\"wp-block-heading\">Revis\u00e3o m\u00e9dia e material<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter specification needs the actual exposure conditions. List process connection, wetted parts and environmental requirements. Include drawing references where a nominal description leaves geometry unclear. Avoid relying on a marketing family name as the assembly specification.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-installation-details\" class=\"wp-block-heading\">Mems pressure transmitter: installation details<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The installed mems pressure transmitter should follow the accepted application drawing. Keep avoidable installation effects out of the measurement where practical. Correct placement, representative conditions and suitable pressure or thermal paths can improve the installed result more directly than selecting a tighter electronics specification.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg\" alt=\"ADDA differential pressure transmitter with two process connections\" class=\"wp-image-1155\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 id=\"signal-and-configuration\" class=\"wp-block-heading\">Sinal e configura\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For mems pressure transmitter, the receiving value must retain the intended interpretation. Compare local measurement, output signal, receiving-system value and operator label. Verify where conversion and compensation occur. Each stage should represent the same intended quantity.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-verification-plan\" class=\"wp-block-heading\">Mems pressure transmitter: verification plan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A pressure source tests the sensing chain; current injection tests the receiving loop. These checks answer different questions. Record increasing and decreasing readings after stabilization, then retain the configuration and reference information so a future technician can reproduce the comparison. Review the complete calibrated assembly rather than comparing chip technology in isolation. Mechanical packaging, temperature effects and the selected range remain part of the measurement error budget.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter acceptance check needs a reproducible comparison. Compare several points and directions where appropriate, allowing stabilization. Keep raw reference and instrument readings so the error can be evaluated in engineering units rather than only as a pass label.<\/p>\n\n\n\n<h2 id=\"maintenance-and-fault-checks\" class=\"wp-block-heading\">Manuten\u00e7\u00e3o e verifica\u00e7\u00f5es de falhas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The mems pressure transmitter service record should explain the observed condition. Investigate whether a disagreement changes with flow, temperature, pressure or range. A changing error suggests a different cause from a fixed scaling mismatch. Preserve the raw observations before applying correction.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-specification-for-adda\" class=\"wp-block-heading\">Mems pressure transmitter: specification for ADDA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter inquiry is strongest when its assumptions are explicit. Issue one reconciled tag sheet with the final configuration. The purchase order, drawing and controls data should refer to the same selected version and revision.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Revise o <a href=\"https:\/\/www.addameter.com\/pt\/produto\/smart-pressure-transmitter\/\">Informa\u00e7\u00f5es de configura\u00e7\u00e3o do Transmissor de Press\u00e3o Inteligente<\/a> e o <a href=\"https:\/\/www.addameter.com\/pt\/products\/\">portf\u00f3lio de produtos ADDA<\/a> ao lado da folha de tags Esses links identificam a fam\u00edlia de produtos relevante; eles n\u00e3o substituem a confirma\u00e7\u00e3o dos materiais, interfaces e limites operacionais ordenados exatos.<\/p>\n\n\n\n<h2 id=\"practical-review-what-the-sensing-chip-does-and-does-not-define\" class=\"wp-block-heading\">Practical review: What the Sensing Chip Does and Does Not Define<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para uma extens\u00e3o de calibre de 10 bar ilustrativa, 12 mA representa 5 bar quando a sa\u00edda \u00e9 linear Um transmissor em uma extens\u00e3o de 016 bar d\u00e1 8 bar na mesma corrente Estes s\u00e3o exemplos de c\u00e1lculo, n\u00e3o classifica\u00e7\u00f5es de modelo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To apply this example to mems pressure transmitter, begin with the actual drawing and collect the inputs that what the Sensing Chip Does and Does Not Define requires. Mark each input as measured, specified or still awaiting confirmation. Compare the result with the normal operating point, then repeat the review at the relevant low or high condition. This makes an assumption visible before it becomes an unexplained offset in the control system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uma revis\u00e3o pr\u00e1tica deve deixar tr\u00eas registros utiliz\u00e1veis: o arranjo f\u00edsico que foi verificado, a configura\u00e7\u00e3o que implementa a interpreta\u00e7\u00e3o pretendida e as observa\u00e7\u00f5es usadas para julgar o resultado Se alguma dessas altera\u00e7\u00f5es, identifique quais conclus\u00f5es precisam ser repetidas Isso \u00e9 especialmente \u00fatil quando um instrumento de substitui\u00e7\u00e3o tem o mesmo nome de fam\u00edlia, mas uma op\u00e7\u00e3o diferente de alcance, conex\u00e3o, sonda, sa\u00edda ou eletr\u00f4nica.<\/p>\n\n\n\n<h2 id=\"technology-and-configuration-comparison\" class=\"wp-block-heading\">Compara\u00e7\u00e3o de tecnologia e configura\u00e7\u00e3o<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Op\u00e7\u00e3o<\/th><th>Considera\u00e7\u00e3o de aplica\u00e7\u00e3o<\/th><th>Provas a solicitar<\/th><\/tr><\/thead><tbody><tr><td>Medi\u00e7\u00e3o de calibre<\/td><td>refer\u00eancia atmosf\u00e9rica e press\u00e3o normal da linha<\/td><td>Base de erro e denominador registrados<\/td><\/tr><tr><td>Medi\u00e7\u00e3o absoluta<\/td><td>refer\u00eancia de v\u00e1cuo e c\u00e1lculos de press\u00e3o<\/td><td>Contribui\u00e7\u00f5es instaladas consideradas<\/td><\/tr><tr><td>Medi\u00e7\u00e3o diferencial<\/td><td>dois pontos de processo e tarefas de queda de press\u00e3o<\/td><td>Toler\u00e2ncia de aceita\u00e7\u00e3o definida em unidades de processo<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use this comparison to structure a mems pressure transmitter review, rather than to rank every technology for every process. The preferred option is the one that meets the required measurement task within the available installation and maintenance conditions. Compare supplier offers against the same operating envelope and ask for explicit exceptions when an option cannot meet one of the requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para obter informa\u00e7\u00f5es independentes, consulte <a href=\"https:\/\/www.nist.gov\/programs-projects\/pressurevacuum-calibrations\" target=\"_blank\" rel=\"noopener\">Informa\u00e7\u00f5es de calibra\u00e7\u00e3o de press\u00e3o e v\u00e1cuo do NIST<\/a>. Esta refer\u00eancia fornece contexto t\u00e9cnico geral ou de metrologia N\u00e3o \u00e9 evid\u00eancia de que um determinado produto ADDA tenha sido certificado, aprovado ou calibrado por essa organiza\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Discuss your mems pressure transmitter application with ADDA.<\/strong> Send the operating data and drawing through the form below, including the specific issue of what the Sensing Chip Does and Does Not Define. Request a configuration review, the relevant product information and confirmation of any outstanding application assumptions before placing the order.<\/p>\n\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Perguntas frequentes<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-12-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What should be confirmed first for mems pressure transmitter?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Start with the physical quantity, reference and operating task. For this application, the central issue is what the Sensing Chip Does and Does Not Define. Confirm the actual process conditions and the installation drawing before selecting a range or accepting a numerical comparison. This avoids choosing an instrument around a label while leaving the measurement basis unresolved.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Which information does ADDA need for a mems pressure transmitter inquiry?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Forne\u00e7a a localiza\u00e7\u00e3o da etiqueta, condi\u00e7\u00f5es operacionais m\u00ednimas e m\u00e1ximas, meio, conex\u00e3o de processo, sa\u00edda necess\u00e1ria e espa\u00e7o de instala\u00e7\u00e3o dispon\u00edvel Inclua o desenho para um conjunto de press\u00e3o de sil\u00edcio ou MEMS em uma m\u00e1quina OEM, juntamente com as evid\u00eancias necess\u00e1rias Solicite a configura\u00e7\u00e3o exata oferecida e uma lista de suposi\u00e7\u00f5es, particularmente quando uma fam\u00edlia de cat\u00e1logo inclui v\u00e1rios materiais ou interfaces opcionais.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How should mems pressure transmitter acceptance be documented?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Registre o arranjo instalado e as configura\u00e7\u00f5es finais, depois retenha observa\u00e7\u00f5es que demonstrem a tarefa pretendida A revis\u00e3o deve abranger: Base de erro e denominador registrado; Contribui\u00e7\u00f5es instaladas consideradas; Toler\u00e2ncia de aceita\u00e7\u00e3o definida em unidades de processo Identifique o m\u00e9todo de compara\u00e7\u00e3o e quais partes da cadeia de medi\u00e7\u00e3o ele inclui Uma simula\u00e7\u00e3o el\u00e9trica, compara\u00e7\u00e3o f\u00edsica e inspe\u00e7\u00e3o de instala\u00e7\u00e3o fornecem evid\u00eancias diferentes e devem permanecer claramente rotuladas.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-4\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Can one mems pressure transmitter setting be used for every operating condition?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Somente se o envelope operacional completo tiver sido revisado e as suposi\u00e7\u00f5es de medi\u00e7\u00e3o permanecerem v\u00e1lidas Mudan\u00e7as nas propriedades do processo, temperatura, geometria ou tempo dos dados podem alterar o resultado Definir quais condi\u00e7\u00f5es compartilham uma configura\u00e7\u00e3o e quais exigem avalia\u00e7\u00e3o adicional; n\u00e3o ocultar uma diferen\u00e7a inexplic\u00e1vel com um deslocamento de exibi\u00e7\u00e3o permanente.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-5\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">When should the mems pressure transmitter configuration be reviewed again?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Revise-o ap\u00f3s uma mudan\u00e7a de processo relevante, substitui\u00e7\u00e3o de instrumento, modifica\u00e7\u00e3o de instala\u00e7\u00e3o ou discord\u00e2ncia inexplic\u00e1vel repetida Preserve as configura\u00e7\u00f5es e observa\u00e7\u00f5es anteriores para que o efeito da mudan\u00e7a possa ser avaliado O objetivo \u00e9 reproduzir uma medi\u00e7\u00e3o confi\u00e1vel sob as novas condi\u00e7\u00f5es, em vez de simplesmente restaurar um n\u00famero familiar na tela.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class='fluentform ff-default fluentform_wrapper_3 ffs_default_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" action=\"\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u5b98\u7f51\u8be2\u76d8<\/legend>        <div\n                style=\"display: none!important; position: absolute!important; transform: translateX(1000%)!important;\"\n                class=\"ff-el-group ff-hpsf-container\"\n        >\n            <div class=\"ff-el-input--label asterisk-right\">\n                <label for=\"ff_3_item_sf\" aria-label=\"Atualiza\u00e7\u00f5es\">\n                    Atualiza\u00e7\u00f5es                <\/label>\n            <\/div>\n            <div class=\"ff-el-input--content\">\n                <input type=\"text\"\n                       name=\"item_3__fluent_sf\"\n                       class=\"ff-el-form-control\"\n                       id=\"ff_3_item_sf\"\n                \/>\n            <\/div>\n        <\/div>\n        <input type='hidden' name='__fluent_form_embded_post_id' value='4109' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"fb1033f20e\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/pt\/wp-json\/wp\/v2\/posts\/4109\" \/><div data-name=\"ff_cn_id_1\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_input_text' id='label_ff_3_input_text' aria-label=\"Nome\">Nome<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text\" class=\"ff-el-form-control\" placeholder=\"Nome\" data-name=\"input_text\" id=\"ff_3_input_text\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_subject' id='label_ff_3_subject' aria-label=\"Telefone\">Telefone<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"Telefone\" data-name=\"subject\" id=\"ff_3_subject\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email' aria-label=\"E-mail\">E-mail<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"Endere\u00e7o de e-mail\" data-name=\"email\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_message' id='label_ff_3_message' aria-label=\"Sua Mensagem\">Sua Mensagem<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_3_message\" name=\"message\" id=\"ff_3_message\" class=\"ff-el-form-control\" placeholder=\"Sua Mensagem\" rows=\"5\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Enviar Formul\u00e1rio\">Enviar Formul\u00e1rio<\/button><\/div><\/fieldset><input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/www.addameter.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"input_text\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>","protected":false},"excerpt":{"rendered":"<p>Mems pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on what the Sensing Chip Does and Does Not Define in a silicon or MEMS pressure assembly on an OEM machine. The aim is to build an error budget around the value the process actually needs [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":443,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Mems pressure transmitter | ADDA Guide","rank_math_description":"Mems pressure transmitter: what the Sensing Chip Does and Does Not Define. Review practical selection, installation and verification points with ADDA.","rank_math_canonical_url":"https:\/\/www.addameter.com\/mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define\/","rank_math_focus_keyword":"mems pressure transmitter"},"categories":[22],"tags":[],"class_list":["post-4109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/posts\/4109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/comments?post=4109"}],"version-history":[{"count":2,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/posts\/4109\/revisions"}],"predecessor-version":[{"id":4656,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/posts\/4109\/revisions\/4656"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/media\/443"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/media?parent=4109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/categories?post=4109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/pt\/wp-json\/wp\/v2\/tags?post=4109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}