{"id":4058,"date":"2026-10-14T01:48:03","date_gmt":"2026-10-14T01:48:03","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-kl-coriolis-mass-flow-meter\/"},"modified":"2026-10-26T03:01:27","modified_gmt":"2026-10-26T03:01:27","slug":"adda-fl-zl-coriolis-mass-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/ko\/product\/adda-fl-zl-coriolis-mass-flow-meter\/","title":{"rendered":"ADDA-FL-ZL Coriolis Mass Flow Meter"},"content":{"rendered":"<p><a href=\"#overview\">Overview<\/a> | <a href=\"#specifications\">Specifications<\/a> | <a href=\"#mass-flow-ranges\">Flow Ranges<\/a> | <a href=\"#dimensions\">Dimensions<\/a> | <a href=\"#installation-guidance\">Installation<\/a><\/p>\n<h2 id=\"overview\">Coriolis Mass Flow Measurement<\/h2>\n<p>The ADDA-FL-ZL directly measures mass flow using the Coriolis effect. It also measures density and temperature, with display functions for mass flow, totalized mass, volumetric flow and totalized volume. Integral and remote transmitter arrangements are available.<\/p>\n<h2 id=\"features\">Features<\/h2>\n<ul>\n<li>Direct mass-flow measurement without conversion from intermediate volumetric measurements.<\/li>\n<li>Simultaneous measurement of flow, density and temperature.<\/li>\n<li>Two individually configurable signal outputs for the measured variables.<\/li>\n<li>A turndown ratio of up to 20:1 is listed in the product features; range-table performance conditions are shown below.<\/li>\n<li>Loop self-diagnostics to support fault finding.<\/li>\n<\/ul>\n<h2 id=\"measurement-principle\">Measurement Principle<\/h2>\n<p>Fluid passes through a vibrating measuring tube. The resulting Coriolis force produces a measurable response related to mass flow. Density is derived from the tube&#8217;s resonant behaviour, with temperature compensation for changes in tube stiffness.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-kl-image68.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4040\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-kl-image68.webp\" alt=\"Coriolis measuring tube vibration and force direction diagram\" width=\"232\" height=\"306\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-kl-image68.webp 232w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-kl-image68-227x300.webp 227w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-kl-image68-9x12.webp 9w\" sizes=\"(max-width: 232px) 100vw, 232px\" \/><\/a><figcaption>Coriolis measurement principle<\/figcaption><\/figure>\n<h2 id=\"specifications\">\uae30\uc220 \uc0ac\uc591<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Parameter<\/th>\n<th scope=\"col\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Accuracy options<\/td>\n<td>\u00b10.15%, \u00b10.2%, \u00b10.5% or \u00b11.0%, depending on the ordered configuration<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>\u00b10.05%<\/td>\n<\/tr>\n<tr>\n<td>Density accuracy<\/td>\n<td>\u00b10.5 kg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>\u00b10.2\u00b0C; the parameter table gives a measurement interval of \u2212240\u00b0C to +350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal connection sizes<\/td>\n<td>DN10\u2013DN300<\/td>\n<\/tr>\n<tr>\n<td>Pressure range<\/td>\n<td>1\u201310 MPa, depending on the ordered configuration<\/td>\n<\/tr>\n<tr>\n<td>Relative humidity<\/td>\n<td>\u226495%<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>220 VAC \u00b110%, 50 Hz, or 24 VDC \u00b15%<\/td>\n<\/tr>\n<tr>\n<td>Signal outputs<\/td>\n<td>Pulse; 4\u201320 mA with optional HART; Modbus RTU RS485<\/td>\n<\/tr>\n<tr>\n<td>Displayed variables<\/td>\n<td>Mass flow, totalized mass, volumetric flow, totalized volume, density and temperature<\/td>\n<\/tr>\n<tr>\n<td>Enclosure protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The measurement temperature interval is not a universal operating rating for every configuration. Select the installation form, tube material and temperature version for the application. The catalogue includes homogeneous fluids and high-viscosity media such as honey and oil slurry; discuss the actual medium and operating conditions when selecting a model.<\/p>\n<h2 id=\"mass-flow-ranges\">Mass Flow Ranges<\/h2>\n<p>Rated flow, maximum flow and zero stability are in kg\/h. The complete model designation is ADDA-FL-ZL followed by the sensor size code A01\u2013A15.<\/p>\n<table>\n<caption>Mass flow ranges \u2014 connection sizes and rated flow<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">Connection sizes<\/th>\n<th scope=\"col\">Rated flow kg\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>19<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>270<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>520<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25\/<wbr \/>DN32<\/td>\n<td>3800<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>DN20\/<wbr \/>DN25\/<wbr \/>DN32\/<wbr \/>DN40<\/td>\n<td>6500<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>DN25\/<wbr \/>DN32\/<wbr \/>DN40\/<wbr \/>DN50<\/td>\n<td>10500<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65<\/td>\n<td>24000<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65\/<wbr \/>DN80<\/td>\n<td>55000<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125<\/td>\n<td>100000<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>158000<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>290000<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>DN150\/<wbr \/>DN200\/<wbr \/>DN250<\/td>\n<td>462000<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>950000<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>1600000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Mass flow ranges \u2014 maximum flow and zero stability<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">Maximum flow kg\/h<\/th>\n<th scope=\"col\">Zero stability kg\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>28<\/td>\n<td>0.0014<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>110<\/td>\n<td>0.0055<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>310<\/td>\n<td>0.0155<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>740<\/td>\n<td>0.037<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>5400<\/td>\n<td>0.270<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>9500<\/td>\n<td>0.475<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>15000<\/td>\n<td>0.75<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>34000<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>75000<\/td>\n<td>3.75<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>140000<\/td>\n<td>7.00<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>225000<\/td>\n<td>11.25<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>403000<\/td>\n<td>20.15<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>652000<\/td>\n<td>32.60<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>1550000<\/td>\n<td>77.50<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>2500000<\/td>\n<td>125.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Within a 30:1 turndown ratio, the range table specifies mass-flow error of \u00b10.2%, mass-flow repeatability of \u00b10.05%, and volumetric-flow error of \u00b10.25%. Confirm these performance values for the selected accuracy option.<\/p>\n<h2 id=\"configuration-options\">Configuration Options<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\ud56d\ubaa9<\/th>\n<th scope=\"col\">Available options<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transmitter arrangement<\/td>\n<td>Integral or remote<\/td>\n<\/tr>\n<tr>\n<td>High-temperature arrangement<\/td>\n<td>Remote, +80\u00b0C to +204\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Low-temperature arrangement<\/td>\n<td>Remote, \u2212240\u00b0C to \u221240\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Process-connection and measuring-tube materials<\/td>\n<td>316L, 904L, titanium, C4 steel, Hastelloy C-276, duplex 2205 or tantalum<\/td>\n<\/tr>\n<tr>\n<td>Flange standards listed<\/td>\n<td>HG\/T 20592-2009, HG\/T 20615-2010 or ANSI B16.5<\/td>\n<\/tr>\n<tr>\n<td>Pressure designations listed<\/td>\n<td>PN10, PN16, PN25, PN40, PN63 or PN100; confirm the applicable flange class and standard<\/td>\n<\/tr>\n<tr>\n<td>Sealing faces<\/td>\n<td>RF, M, T, RJ or a custom arrangement<\/td>\n<\/tr>\n<tr>\n<td>Electrical entries<\/td>\n<td>M20 \u00d7 1.5 or 1\/2 NPT<\/td>\n<\/tr>\n<tr>\n<td>Hazardous-area option<\/td>\n<td>Flameproof option listed as Exdb IIC T6 Gb, or a non-explosion-protected configuration. Confirm the actual marking and supporting documentation for the ordered model.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"dimensions\">Dimensions A01\u2013A15<\/h2>\n<p>All dimensions are in millimetres. Dimension A can be customized.<\/p>\n<h3>Remote transmitter<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId91.png\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId91.png\" alt=\"Remote transmitter dimensional drawing\" style=\"max-width:100%;height:auto\" \/><\/a><figcaption>Remote transmitter dimensional drawing<\/figcaption><\/figure>\n<table>\n<caption>Remote transmitter dimensions<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">A<\/th>\n<th scope=\"col\">B<\/th>\n<th scope=\"col\">C<\/th>\n<th scope=\"col\">D<\/th>\n<th scope=\"col\">E<\/th>\n<th scope=\"col\">F<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>166<\/td>\n<td>288<\/td>\n<td>174<\/td>\n<td>71<\/td>\n<td>264<\/td>\n<td>4 \u00d7 \u00d810<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Remote sensor dimensions<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId92.png\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId92.png\" alt=\"Remote sensor dimensional drawing A B C D E2\" style=\"max-width:100%;height:auto\" \/><\/a><figcaption>Remote sensor dimensional drawing A B C D E2<\/figcaption><\/figure>\n<table>\n<caption>Remote sensors \u2014 connection sizes and A<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">Connection sizes<\/th>\n<th scope=\"col\">A<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>381\u2013405<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25\/<wbr \/>DN32<\/td>\n<td>433\u2013461<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>DN20\/<wbr \/>DN25\/<wbr \/>DN32\/<wbr \/>DN40<\/td>\n<td>441\u2013461<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>DN25\/<wbr \/>DN32\/<wbr \/>DN40\/<wbr \/>DN50<\/td>\n<td>528\u2013548<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65<\/td>\n<td>558\u2013578<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65\/<wbr \/>DN80<\/td>\n<td>509\u2013529<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125<\/td>\n<td>620\u2013660<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>759\u2013799<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>846\u2013892<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>DN150\/<wbr \/>DN200\/<wbr \/>DN250<\/td>\n<td>984\u20131230<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>1024\u20131054<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>1043\u20131129<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Remote sensors \u2014 B C D E2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">B<\/th>\n<th scope=\"col\">C<\/th>\n<th scope=\"col\">D<\/th>\n<th scope=\"col\">E2<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<td>306<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<td>306<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<td>306<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>211<\/td>\n<td>220<\/td>\n<td>60<\/td>\n<td>334<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>283<\/td>\n<td>302<\/td>\n<td>70<\/td>\n<td>416<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>295<\/td>\n<td>301<\/td>\n<td>70<\/td>\n<td>428<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>350<\/td>\n<td>370<\/td>\n<td>85<\/td>\n<td>493<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>426<\/td>\n<td>406<\/td>\n<td>86<\/td>\n<td>569<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>574<\/td>\n<td>420<\/td>\n<td>140<\/td>\n<td>687<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>521<\/td>\n<td>718<\/td>\n<td>530<\/td>\n<td>850<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>813<\/td>\n<td>630<\/td>\n<td>206<\/td>\n<td>957<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>896<\/td>\n<td>720<\/td>\n<td>240<\/td>\n<td>1052<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>952<\/td>\n<td>870<\/td>\n<td>340<\/td>\n<td>1126<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>1219<\/td>\n<td>810<\/td>\n<td>348<\/td>\n<td>1419<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>1338<\/td>\n<td>878<\/td>\n<td>460<\/td>\n<td>1551<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Integral dimensions<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId93.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/rId93.jpg\" alt=\"Integral mass flow meter dimensional drawing A B C D E1 F\" style=\"max-width:100%;height:auto\" \/><\/a><figcaption>Integral mass flow meter dimensional drawing A B C D E1 F<\/figcaption><\/figure>\n<table>\n<caption>Integral meters \u2014 connection sizes and A<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">Connection sizes<\/th>\n<th scope=\"col\">A<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>DN10\/<wbr \/>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>343\u2013353<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25<\/td>\n<td>381\u2013405<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>DN15\/<wbr \/>DN20\/<wbr \/>DN25\/<wbr \/>DN32<\/td>\n<td>433\u2013461<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>DN20\/<wbr \/>DN25\/<wbr \/>DN32\/<wbr \/>DN40<\/td>\n<td>441\u2013461<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>DN25\/<wbr \/>DN32\/<wbr \/>DN40\/<wbr \/>DN50<\/td>\n<td>528\u2013548<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65<\/td>\n<td>558\u2013578<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>DN40\/<wbr \/>(DN50)\/<wbr \/>DN65\/<wbr \/>DN80<\/td>\n<td>509\u2013529<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125<\/td>\n<td>620\u2013660<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>DN80\/<wbr \/>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>759\u2013799<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>DN100\/<wbr \/>DN125\/<wbr \/>DN150<\/td>\n<td>846\u2013892<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>DN150\/<wbr \/>DN200\/<wbr \/>DN250<\/td>\n<td>984\u20131230<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>1024\u20131054<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>DN200\/<wbr \/>DN250\/<wbr \/>DN300<\/td>\n<td>1043\u20131129<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Integral meters \u2014 B C D<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">B<\/th>\n<th scope=\"col\">C<\/th>\n<th scope=\"col\">D<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>183<\/td>\n<td>216<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>211<\/td>\n<td>220<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>283<\/td>\n<td>302<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>295<\/td>\n<td>301<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>350<\/td>\n<td>370<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>426<\/td>\n<td>406<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>574<\/td>\n<td>420<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>521<\/td>\n<td>718<\/td>\n<td>530<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>813<\/td>\n<td>630<\/td>\n<td>206<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>896<\/td>\n<td>720<\/td>\n<td>240<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>952<\/td>\n<td>870<\/td>\n<td>340<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>1219<\/td>\n<td>810<\/td>\n<td>348<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>1338<\/td>\n<td>878<\/td>\n<td>460<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Integral meters \u2014 E1 and F<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Sensor size<\/th>\n<th scope=\"col\">E1<\/th>\n<th scope=\"col\">F<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A01<\/td>\n<td>451<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A02<\/td>\n<td>451<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A03<\/td>\n<td>451<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A04<\/td>\n<td>479<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A05<\/td>\n<td>561<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A06<\/td>\n<td>573<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A07<\/td>\n<td>638<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A08<\/td>\n<td>714<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A09<\/td>\n<td>832<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A10<\/td>\n<td>995<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A11<\/td>\n<td>1102<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A12<\/td>\n<td>1198<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A13<\/td>\n<td>1271<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A14<\/td>\n<td>1564<\/td>\n<td>173<\/td>\n<\/tr>\n<tr>\n<td>A15<\/td>\n<td>1696<\/td>\n<td>173<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"installation-guidance\">Installation Guidance<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Application<\/th>\n<th scope=\"col\">Recommended orientation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Liquids<\/td>\n<td>Horizontal pipe with the sensor housing below the pipe to limit trapped air<\/td>\n<\/tr>\n<tr>\n<td>Gases<\/td>\n<td>Horizontal pipe with the sensor housing above the pipe to limit condensate accumulation<\/td>\n<\/tr>\n<tr>\n<td>Liquids or solid\u2013liquid mixtures<\/td>\n<td>Vertical pipe arrangement to limit particle accumulation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li>Keep the sensor away from pumps and other sources of mechanical pipe vibration, as well as large motors, transformers and other electromagnetic interference sources.<\/li>\n<li>For liquid measurement, keep the measuring tubes full and maintain suitable back pressure. Select a low point in the pipeline where appropriate.<\/li>\n<li>Account for thermal expansion and pipe deformation; do not position the meter close to a pipeline expansion joint.<\/li>\n<li>Connect the sensor and pipe flanges coaxially without installation stress.<\/li>\n<li>Provide shutoff valves upstream and downstream. Secure the pipe and valves to a stable foundation with suitable supports.<\/li>\n<li>Do not use the sensor housing to support the sensor, pipe, valves or pumps. The sensor housing should remain freely suspended after installation.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\ubc00\ub3c4 \ubc0f \uc628\ub3c4 \uce21\uc815\uc73c\ub85c \uc9c1\uc811 \uc9c8\ub7c9 \uc720\ub7c9 \uce21\uc815\uc744 \uc704\ud55c \ucf54\ub9ac\uc62c\ub9ac \uc9c8\ub7c9 \uc720\ub7c9\uacc4. \uc77c\uccb4\ud615 \ubc0f \uc6d0\uaca9 \ud2b8\ub79c\uc2a4\ubbf8\ud130 \uad6c\uc131\uc744 \uc0ac\uc6a9\ud560 \uc218 \uc788\uc73c\uba70,\uc13c\uc11c \ubc0f \uc5f0\uacb0 \ud06c\uae30\ub294 \ud544\uc694\ud55c \uc720\ub7c9 \ubc94\uc704\uc5d0 \ub9de\uac8c \uc120\ud0dd\ub429\ub2c8\ub2e4.<\/p>","protected":false},"featured_media":4018,"template":"","meta":{"rank_math_title":"ADDA-FL-ZL Coriolis Mass Flow Meter | Density and Flow","rank_math_description":"The ADDA-FL-ZL Coriolis mass flow meter measures mass flow, density and temperature, with integral or remote transmitter arrangements available.","rank_math_canonical_url":"","rank_math_focus_keyword":"Coriolis Mass Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4058","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/product\/4058","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/media\/4018"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/media?parent=4058"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/product_brand?post=4058"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/product_cat?post=4058"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ko\/wp-json\/wp\/v2\/product_tag?post=4058"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}