{"id":4055,"date":"2026-10-14T01:48:03","date_gmt":"2026-10-14T01:48:03","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-wl-liquid-turbine-flow-meter\/"},"modified":"2026-10-21T04:00:17","modified_gmt":"2026-10-21T04:00:17","slug":"adda-fl-wl-liquid-turbine-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/hi\/product\/adda-fl-wl-liquid-turbine-flow-meter\/","title":{"rendered":"ADDA-FL-WL \u0924\u0930\u0932 \u091f\u0930\u092c\u093e\u0907\u0928 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u0940\u091f\u0930"},"content":{"rendered":"<p><a href=\"#overview\">\u0905\u0935\u0932\u094b\u0915\u0928<\/a> | <a href=\"#specifications\">\u0928\u093f\u0930\u094d\u0926\u093f\u0937\u094d\u091f\u0940\u0915\u0930\u0923<\/a> | <a href=\"#liquid-flow-ranges\">\u092a\u094d\u0930\u0935\u093e\u0939 \u0936\u094d\u0930\u0947\u0923\u093f\u092f\u093e\u0901<\/a> | <a href=\"#dimensions\">\u0906\u092f\u093e\u092e<\/a> | <a href=\"#installation-requirements\">Installation<\/a><\/p>\n<h2 id=\"overview\">\u0905\u0935\u0932\u094b\u0915\u0928<\/h2>\n<p>The ADDA-FL-WL is a velocity-type turbine flow meter for clean, low-viscosity liquids that are not strongly corrosive. Liquid passing through the meter drives a rotor; its speed is converted into an electrical signal proportional to flow. The series is used in food and pharmaceutical processing, fine chemicals, petroleum and other liquid measurement applications.<\/p>\n<p>Select the wetted materials, process connection and electronics to suit the liquid, operating pressure, temperature and required flow range.<\/p>\n<h2 id=\"features\">\u0935\u093f\u0936\u0947\u0937\u0924\u093e\u090f\u0902<\/h2>\n<ul>\n<li>Nominal sizes from DN4 to DN300, depending on connection type.<\/li>\n<li>GA versions without local display and GN versions with an integral LCD.<\/li>\n<li>Pulse, 4\u201320 mA, Modbus RTU over RS485 and HART options, depending on electronics.<\/li>\n<li>GN versions display volumetric flow and can calculate mass flow from a configured liquid density.<\/li>\n<li>Threaded, flanged, wafer and sanitary clamp connection options.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">\u0911\u092a\u0930\u0947\u091f\u093f\u0902\u0917 \u0938\u093f\u0926\u094d\u0927\u093e\u0902\u0924<\/h2>\n<p>The flowing liquid applies torque to the angled turbine blades. Within the calibrated operating range, rotor speed is proportional to average liquid velocity. A magnetic pickup detects the rotating blades and generates pulses; the electronics process these pulses to indicate instantaneous flow and totalized volume.<\/p>\n<p>Q = 3.6 \u00d7 f \/ K, where Q is volumetric flow at operating conditions in m\u00b3\/h, f is pulse frequency in Hz, and K is the meter factor in pulses per litre. Use the meter factor stated in the individual calibration report.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4052\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp\" alt=\"Turbine rotor, electromagnetic conversion, pulse calculation and output diagram\" width=\"1200\" height=\"430\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp 1200w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-300x108.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-1024x367.webp 1024w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-768x275.webp 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-18x6.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-600x215.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><figcaption>Turbine flow measurement principle<\/figcaption><\/figure>\n<h2 id=\"specifications\">\u0924\u0915\u0928\u0940\u0915\u0940 \u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th>\n<th scope=\"col\">\u0935\u093f\u0936\u093f\u0937\u094d\u091f\u0924\u093e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Model<\/th>\n<td>ADDA-FL-WL<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Suitable liquids<\/th>\n<td>Clean liquids without solid impurities; kinematic viscosity below 10 mm\u00b2\/s; not strongly corrosive<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Meter body<\/th>\n<td>304 or 316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor materials, DN4\u2013DN125<\/th>\n<td>2Cr13 stainless steel or 2205 duplex stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor materials, DN150\u2013DN300<\/th>\n<td>304 hub with 430 blades, or 316 hub with 2205 duplex stainless steel blades<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process temperature<\/th>\n<td>\u221240 to +120\u00b0C or \u221240 to +150\u00b0C, depending on version; \u221240 to +80\u00b0C option also listed in the ordering guide<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ambient temperature<\/th>\n<td>\u221220 to +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Relative humidity<\/th>\n<td>5\u201395%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<td>PN10\u2013PN400 or Class 150\u20132500, depending on nominal size and connection<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accuracy options<\/th>\n<td>Version-dependent; see electronics table below. Class 0.2 is available on request.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced product standard<\/th>\n<td>JB\/T 9246-2016, Turbine Flow Sensors<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced verification regulation<\/th>\n<td>JJG 1037-2008, Turbine Flowmeters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>\u092a\u094d\u0930\u0915\u094d\u0930\u093f\u092f\u093e \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0935\u093f\u0915\u0932\u094d\u092a<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Connection<\/th>\n<th scope=\"col\">Available nominal sizes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">External thread<\/th>\n<td>DN4\u2013DN80<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Internal thread<\/th>\n<td>DN4\u2013DN50<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flanged<\/th>\n<td>DN4\u2013DN300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Wafer<\/th>\n<td>DN15\u2013DN200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Sanitary clamp<\/th>\n<td>DN4\u2013DN100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"electronics-versions\">Electronics Versions<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u092a\u0948\u0930\u093e\u092e\u0940\u091f\u0930<\/th>\n<th scope=\"col\">GA without local display<\/th>\n<th scope=\"col\">GN with integral LCD<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Function<\/th>\n<td>Remote transmission for flow computers, PLCs and control systems<\/td>\n<td>Local indication and remote signal transmission<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accuracy classes<\/th>\n<td>2.5, 1.5, 1.0 or 0.5<\/td>\n<td>0.5, 0.3 or 0.2; class 0.2 on request<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Repeatability<\/th>\n<td>Better than 0.15%<\/td>\n<td>Better than 0.15%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0906\u092a\u0942\u0930\u094d\u0924\u093f<\/th>\n<td>24 V DC nominal; 5\u201332 V DC or 16\u201332 V DC depending on output<\/td>\n<td>24 V DC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f \u0935\u093f\u0915\u0932\u094d\u092a<\/th>\n<td>Pulse or 4\u201320 mA<\/td>\n<td>Pulse or two-wire 4\u201320 mA; HART and Modbus RTU over RS485 configurations available<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electrical connections<\/th>\n<td>Circular plug, cable lead or Hirschmann-type connector<\/td>\n<td>M20 \u00d7 1.5 or 1\/2 NPT<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u092a\u094d\u0930\u0935\u0947\u0936 \u0938\u0941\u0930\u0915\u094d\u0937\u093e<\/th>\n<td>IP65 or IP67, depending on version<\/td>\n<td>\u0906\u0908\u092a\u094067<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Output, power-supply and protection options must be selected as a compatible configuration. Hazardous-area versions are available on request; confirm the marking and applicable certification for the supplied unit.<\/p>\n<h2 id=\"liquid-flow-ranges\">Liquid Flow Ranges<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0928\u093e\u092e\u092e\u093e\u0924\u094d\u0930 \u0906\u0915\u093e\u0930<\/th>\n<th scope=\"col\">Flow range (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>0.04\u20130.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>0.06\u20130.6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.15\u20131.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.5\u20136<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.45\u20139<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>0.5\u201310<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>0.8\u201315<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>1\u201320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>2\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>5\u201370<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>7\u2013100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>10\u2013200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>13\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>15\u2013300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>40\u2013800<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>100\u20131000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>120\u20131200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Select a size so that the normal operating flow is preferably within 20\u201380% of the selected meter\u2019s maximum flow. Confirm suitability against liquid properties and process conditions.<\/p>\n<h2 id=\"pressure-rating-options\">Pressure Rating Options<\/h2>\n<table>\n<caption>Pressure Rating Options \u2014 Part 1 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">External thread PN<\/th>\n<th scope=\"col\">Internal thread PN<\/th>\n<th scope=\"col\">Flanged PN<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>16\u201363<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>16\u201363<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u201340<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Pressure Rating Options \u2014 Part 2 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Flanged Class<\/th>\n<th scope=\"col\">Wafer PN<\/th>\n<th scope=\"col\">Wafer Class<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>150\u2013300<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>150\u2013300<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>150<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Pressure Rating Options \u2014 Part 3 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Clamp PN<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PN and Class are separate rating systems. Available ratings depend on the connection and size. Entries marked \u201c\u2014\u201d are not specified here; confirm on request.<\/p>\n<h2 id=\"selection-options\">Selection Options<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u091a\u092f\u0928<\/th>\n<th scope=\"col\">\u0915\u094b\u0921<\/th>\n<th scope=\"col\">\u0935\u093f\u0915\u0932\u094d\u092a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Electronics<\/th>\n<td>GA<\/td>\n<td>Without local display<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electronics<\/th>\n<td>\u091c\u0940\u090f\u0928<\/td>\n<td>Integral LCD<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F1<\/td>\n<td>Flanged<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F2<\/td>\n<td>Wafer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F3<\/td>\n<td>Sanitary clamp<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>L1<\/td>\n<td>External thread<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>L2<\/td>\n<td>Internal thread<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>4<\/td>\n<td>304 \u0938\u094d\u091f\u0947\u0928\u0932\u0947\u0938 \u0938\u094d\u091f\u0940\u0932<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>6<\/td>\n<td>316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor material<\/th>\n<td>2C<\/td>\n<td>2Cr13 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor material<\/th>\n<td>25<\/td>\n<td>2205 duplex stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GA1<\/td>\n<td>24 V DC, no local display, 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GA2<\/td>\n<td>24 V DC, no local display, pulse<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GN1<\/td>\n<td>24 V DC, local display, pulse<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GN2<\/td>\n<td>24 V DC, local display, 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GN3<\/td>\n<td>24 V DC, local display, 4\u201320 mA + HART<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0906\u0909\u091f\u092a\u0941\u091f<\/th>\n<td>GN4<\/td>\n<td>24 V DC, local display, Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>1<\/td>\n<td>\u221240 to +80\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>2<\/td>\n<td>\u221240 to +120\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>3<\/td>\n<td>\u221240 to +150\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>N<\/td>\n<td>Non-explosion-protected version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>D<\/td>\n<td>Flameproof version; confirm marking and certification for the selected configuration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>State the required nominal size, pressure rating, accuracy class, electrical connection and transmitter appearance when ordering. The final configuration must be confirmed for the application.<\/p>\n<h2 id=\"dimensions\">\u0906\u092f\u093e\u092e<\/h2>\n<p>Dimensions are in millimetres unless otherwise stated. Use the dimensional drawing and table for the selected connection and pressure rating.<\/p>\n<h3>External Thread Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4023\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp\" alt=\"ADDA-FL-WL turbine flow meter side-view dimensional drawing with threaded ends\" width=\"606\" height=\"420\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp 606w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-300x208.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-600x416.webp 600w\" sizes=\"(max-width: 606px) 100vw, 606px\" \/><\/a><figcaption>External-thread connection, DN4\u2013DN10, with straight pipe sections<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4024\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp\" alt=\"ADDA-FL-WL threaded turbine flow meter side and end dimensions\" width=\"745\" height=\"641\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp 745w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-300x258.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-14x12.webp 14w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-600x516.webp 600w\" sizes=\"(max-width: 745px) 100vw, 745px\" \/><\/a><figcaption>External-thread connection, DN15\u2013DN80<\/figcaption><\/figure>\n<p>DN4\u2013DN10 external-thread versions include straight pipe sections. DN15\u2013DN80 versions do not include straight pipe sections.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">G male thread<\/th>\n<th scope=\"col\">b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN63 or lower<\/td>\n<td>296<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN63 or lower<\/td>\n<td>296<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN63 or lower<\/td>\n<td>413<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G1<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN63 or lower<\/td>\n<td>85<\/td>\n<td>G1<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>PN63 or lower<\/td>\n<td>100<\/td>\n<td>G1-1\/4<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN63 or lower<\/td>\n<td>140<\/td>\n<td>G2<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>PN63 or lower<\/td>\n<td>140<\/td>\n<td>G2<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>PN63 or lower<\/td>\n<td>150<\/td>\n<td>G2-1\/2<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN63 or lower<\/td>\n<td>170<\/td>\n<td>G3<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>PN63 or lower<\/td>\n<td>200<\/td>\n<td>G4<\/td>\n<td>40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Internal Thread Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4025\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp\" alt=\"ADDA-FL-WL flanged turbine flow meter side-view dimensional drawing\" width=\"549\" height=\"705\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp 549w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10-234x300.webp 234w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10-9x12.webp 9w\" sizes=\"(max-width: 549px) 100vw, 549px\" \/><\/a><figcaption>Internal-thread connection, DN4\u2013DN50<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">G female thread<\/th>\n<th scope=\"col\">\u0921\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G3\/8<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G3\/8<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G1\/2<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN63 or lower<\/td>\n<td>100<\/td>\n<td>G1\/2<\/td>\n<td>44<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G3\/4<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1<\/td>\n<td>49<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1-1\/4<\/td>\n<td>56<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1-1\/2<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G2<\/td>\n<td>72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Flanged Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4026\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp\" alt=\"ADDA-FL-WL turbine flow meter side and end dimensional views\" width=\"750\" height=\"441\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp 750w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-300x176.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-600x353.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><figcaption>Small-bore flanged connection with straight pipe sections<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4027\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp\" alt=\"ADDA-FL-WL flange bolt pattern and transmitter dimensional views\" width=\"714\" height=\"489\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp 714w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-300x205.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-600x411.webp 600w\" sizes=\"(max-width: 714px) 100vw, 714px\" \/><\/a><figcaption>Flanged connection dimensions<\/figcaption><\/figure>\n<table>\n<caption>PN flange dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">\u0921\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN40 or lower<\/td>\n<td>296<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN40 or lower<\/td>\n<td>296<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN40 or lower<\/td>\n<td>413<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN40 or lower<\/td>\n<td>75<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN40 or lower<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>PN40 or lower<\/td>\n<td>100<\/td>\n<td>115<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN40 or lower<\/td>\n<td>140<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>PN40 or lower<\/td>\n<td>140<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>PN40 or lower<\/td>\n<td>150<\/td>\n<td>165<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN16<\/td>\n<td>170<\/td>\n<td>185<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>PN16<\/td>\n<td>200<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>PN16<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>PN16<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>PN16<\/td>\n<td>300<\/td>\n<td>285<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>PN16<\/td>\n<td>350<\/td>\n<td>340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>PN16<\/td>\n<td>400<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>PN16<\/td>\n<td>350<\/td>\n<td>460<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>PN flange dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">K (mm)<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">n holes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>75<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>85<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>100<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>110<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>125<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>145<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>160<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>180<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>210<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>240<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>295<\/td>\n<td>22<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>355<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>410<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Class 150 flange dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Pressure class<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">\u0921\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>Class150<\/td>\n<td>296<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>Class150<\/td>\n<td>296<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>Class150<\/td>\n<td>413<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>Class150<\/td>\n<td>75<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>Class150<\/td>\n<td>85<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>Class150<\/td>\n<td>100<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>Class150<\/td>\n<td>140<\/td>\n<td>115<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>Class150<\/td>\n<td>140<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>Class150<\/td>\n<td>150<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>Class150<\/td>\n<td>170<\/td>\n<td>180<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>Class150<\/td>\n<td>200<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>Class150<\/td>\n<td>220<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>Class150<\/td>\n<td>250<\/td>\n<td>255<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>Class150<\/td>\n<td>300<\/td>\n<td>280<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>Class150<\/td>\n<td>350<\/td>\n<td>345<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>Class150<\/td>\n<td>400<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>Class150<\/td>\n<td>350<\/td>\n<td>485<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Class 150 flange dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">K (mm)<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">n holes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>69.9<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>79.4<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>88.9<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>98.4<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>120.7<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>139.7<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>152.4<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>190.5<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>215.9<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>241.3<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>298.5<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928250<\/th>\n<td>362<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>431.8<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Wafer Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4028\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp\" alt=\"ADDA-FL-WL flanged turbine flow meter side and front dimensions\" width=\"544\" height=\"476\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp 544w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14-300x263.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14-14x12.webp 14w\" sizes=\"(max-width: 544px) 100vw, 544px\" \/><\/a><figcaption>Wafer connection dimensions<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">\u0921\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN400 or lower<\/td>\n<td>65<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN400 or lower<\/td>\n<td>60<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>PN400 or lower<\/td>\n<td>60<\/td>\n<td>58<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>72<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN400 or lower<\/td>\n<td>80<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>PN400 or lower<\/td>\n<td>90<\/td>\n<td>112<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>PN400 or lower<\/td>\n<td>100<\/td>\n<td>137<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>PN400 or lower<\/td>\n<td>120<\/td>\n<td>165<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928150<\/th>\n<td>PN400 or lower<\/td>\n<td>150<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928200<\/th>\n<td>PN400 or lower<\/td>\n<td>150<\/td>\n<td>242<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The catalogue gives the same wafer body dimensions across the available pressure ratings. When supplied with mating weld-neck flanges, total length equals the standard body length plus twice the mating-flange thickness.<\/p>\n<h3>Sanitary Clamp Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4029\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp\" alt=\"ADDA-FL-WL compact turbine flow meter body and transmitter dimensions\" width=\"391\" height=\"469\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp 391w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15-250x300.webp 250w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15-10x12.webp 10w\" sizes=\"(max-width: 391px) 100vw, 391px\" \/><\/a><figcaption>Sanitary clamp connection dimensions<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4030\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp\" alt=\"ADDA-FL-WL turbine flow meter transmitter and flange front view\" width=\"147\" height=\"306\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp 147w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16-144x300.webp 144w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16-6x12.webp 6w\" sizes=\"(max-width: 147px) 100vw, 147px\" \/><\/a><figcaption>Sanitary clamp connection end view<\/figcaption><\/figure>\n<table>\n<caption>Sanitary Clamp Connection \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">\u0926\u092c\u093e\u0935 \u0930\u0947\u091f\u093f\u0902\u0917<\/th>\n<th scope=\"col\">\u090f\u0932 (\u092e\u093f\u092e\u0940)<\/th>\n<th scope=\"col\">\u0921\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN10<\/td>\n<td>120<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>PN10<\/td>\n<td>140<\/td>\n<td>64<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>PN10<\/td>\n<td>150<\/td>\n<td>77.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN10<\/td>\n<td>170<\/td>\n<td>91<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>PN10<\/td>\n<td>220<\/td>\n<td>130<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Sanitary Clamp Connection \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">\u0938\u0940 (\u092e\u093f\u092e\u0940)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>4<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>6<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>10<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>15<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>20<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092825<\/th>\n<td>25<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>32<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092840<\/th>\n<td>40<\/td>\n<td>56.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092850<\/th>\n<td>50<\/td>\n<td>70.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>65<\/td>\n<td>83.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u092880<\/th>\n<td>80<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0921\u0940\u090f\u0928100<\/th>\n<td>100<\/td>\n<td>122<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"installation-requirements\">Installation Requirements<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Requirement<\/th>\n<th scope=\"col\">Guidance<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Straight pipe after reducers, expanders or elbows<\/th>\n<td>Provide at least 15D upstream and 5D downstream. D is the nominal internal diameter of the flow meter.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pipe alignment<\/th>\n<td>Align the meter and pipeline concentrically before installation.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cleanliness<\/th>\n<td>Flush new pipework before fitting the meter to remove welding debris and other foreign material.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process connections<\/th>\n<td>Use the mating fittings, gaskets, fasteners and sealing method appropriate to the selected thread, flange, wafer or clamp connection.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>\u0938\u094d\u0935\u091a\u094d\u091b, \u0915\u092e-\u091a\u093f\u092a\u091a\u093f\u092a\u093e\u092a\u0928 \u0924\u0930\u0932 \u092a\u0926\u093e\u0930\u094d\u0925 \u0915\u0947 \u0932\u093f\u090f \u0924\u0930\u0932 \u091f\u0930\u092c\u093e\u0907\u0928 \u092a\u094d\u0930\u0935\u093e\u0939 \u092e\u0940\u091f\u0930 \u0921\u0940\u090f\u0928 \u096a \u090f\u0938\u0921\u0940\u090f\u0928 \u0969\u0966\u0966 \u0935\u093f\u0915\u0932\u094d\u092a \u0925\u094d\u0930\u0947\u0921\u0947\u0921, \u092b\u094d\u0932\u0948\u0902\u0917\u0947\u0921, \u0935\u0947\u092b\u0930 \u092f\u093e \u0938\u0948\u0928\u093f\u091f\u0930\u0940 \u0915\u094d\u0932\u0948\u0902\u092a \u0915\u0928\u0947\u0915\u094d\u0936\u0928 \u0915\u0947 \u0938\u093e\u0925 \u0909\u092a\u0932\u092c\u094d\u0927 \u0939\u0948\u0902 \u0928\u093f\u092f\u0902\u0924\u094d\u0930\u0923 \u092a\u094d\u0930\u0923\u093e\u0932\u0940 \u0915\u0947 \u0905\u0928\u0941\u0930\u0942\u092a \u0906\u0909\u091f\u092a\u0941\u091f \u0935\u093f\u0915\u0932\u094d\u092a\u094b\u0902 \u0915\u0947 \u0938\u093e\u0925, \u090f\u0915 \u0905\u092d\u093f\u0928\u094d\u0928 \u090f\u0932\u0938\u0940\u0921\u0940 \u0915\u0947 \u0938\u093e\u0925 \u0938\u094d\u0925\u093e\u0928\u0940\u092f \u092a\u094d\u0930\u0926\u0930\u094d\u0936\u0928 \u092f\u093e \u091c\u0940\u090f\u0928 \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915\u094d\u0938 \u0915\u0947 \u092c\u093f\u0928\u093e \u091c\u0940\u090f \u0907\u0932\u0947\u0915\u094d\u091f\u094d\u0930\u0949\u0928\u093f\u0915\u094d\u0938 \u0915\u093e \u091a\u092f\u0928 \u0915\u0930\u0947\u0902\u0964.<\/p>","protected":false},"featured_media":4015,"template":"","meta":{"rank_math_title":"ADDA-FL-WL Liquid Turbine Flow Meter | Clean Liquid Flow","rank_math_description":"The ADDA-FL-WL liquid turbine flow meter measures clean, low-viscosity liquids and offers selectable connections, displays and electrical outputs.","rank_math_canonical_url":"","rank_math_focus_keyword":"Liquid Turbine Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4055","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/product\/4055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/media\/4015"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/media?parent=4055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/product_brand?post=4055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/product_cat?post=4055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/hi\/wp-json\/wp\/v2\/product_tag?post=4055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}