{"id":440,"date":"2026-07-07T01:54:40","date_gmt":"2026-07-07T01:54:40","guid":{"rendered":"https:\/\/addameter.com\/product\/temperature-transmitter\/"},"modified":"2026-10-21T04:02:23","modified_gmt":"2026-10-21T04:02:23","slug":"temperature-transmitter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/fr\/produit\/temperature-transmitter\/","title":{"rendered":"Transmetteur de Temp\u00e9rature"},"content":{"rendered":"<style>\n.adda-product-description{font-size:15px;line-height:1.72;color:#4b5563}<br \/>.adda-product-description strong{color:#111827}<br \/>.adda-table-wrap{width:100%;overflow-x:auto;margin:18px 0 26px;border:1px solid #e5e7eb;border-radius:6px;background:#fff}<br \/>.adda-spec-table{width:100%;min-width:720px;border-collapse:collapse;margin:0;font-size:14px;line-height:1.55}<br \/>.adda-spec-table th,.adda-spec-table td{border:1px solid #e5e7eb;padding:11px 14px;vertical-align:top;text-align:left}<br \/>.adda-spec-table th{background:#f6f7f9;color:#111827;font-weight:700}<br \/>.adda-spec-table td:first-child{color:#111827;font-weight:600}<br \/>.adda-spec-table tr:nth-child(even) td{background:#fafafa}<br \/>.adda-spec-table p{margin:0 0 6px}<br \/>.adda-spec-table p:last-child{margin-bottom:0}<br \/>.adda-spec-note{background:#fff8f4!important;color:#374151!important;font-weight:400!important}<br \/>@media (max-width:767px){.adda-product-description{font-size:14px}.adda-spec-table{min-width:680px;font-size:13px}.adda-spec-table th,.adda-spec-table td{padding:9px 11px}}<br \/><\/style>\n<div class=\"adda-product-description\">\n<h3>Transmetteur de Temp\u00e9rature<\/h3>\n<p><strong>Caract\u00e9ristiques du produit<\/strong><\/p>\n<p>The ADDA-T-GY Series thermocouple and RTD temperature transmitter measures, transmits, and displays the temperature of solid surfaces, liquids, and gases. Key features include:<\/p>\n<ul>\n<li>Sealed with silicone rubber or epoxy resin for vibration and moisture resistance; suitable for harsh operating environments.<\/li>\n<li>High accuracy, low quiescent power consumption, stable and reliable operation, and long service life.<\/li>\n<li>Two-wire 4mA.dc.~20mA.dc output with strong interference resistance and long transmission distance.<\/li>\n<li>Digital cold-junction compensation and nonlinear correction.<\/li>\n<li>Intrinsically safe and flameproof versions for installation in Zone 0, Zone 1, Zone 2, and other hazardous areas.<\/li>\n<li>The digital display orientation can be adjusted to suit installation requirements. It displays measured temperature, output current, and percentage in real time.<\/li>\n<li>HART communication supports local or remote parameter adjustment and monitoring through a handheld communicator.<\/li>\n<\/ul>\n<p><strong>Applications<\/strong><\/p>\n<p>Temperature measurement in petroleum, chemical, metallurgical, electric power, and other industries.<\/p>\n<p><strong>Mesure du milieu<\/strong><\/p>\n<p>M\u00e9dia compatible avec les mat\u00e9riaux mouill\u00e9s.<\/p>\n<p><strong>Performance Sp\u00e9cifications<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Pr\u00e9cision<\/th>\n<th>\u00b10.1%, \u00b10.2%, 0.5% Upper Range Limit, \u00a0see specifications for details<\/th>\n<\/tr>\n<tr>\n<td>Gamme<\/td>\n<td>-230~1820 degrees C, see selection table for details<\/td>\n<\/tr>\n<tr>\n<td>Stabilit\u00e9 annuelle<\/td>\n<td>\u00b10.1% Span\/2 years<\/td>\n<\/tr>\n<tr>\n<td>Influence de tension<\/td>\n<td>When the supply voltage varies within 10.5V\/16.5V~36V DC, changes in zero point and span shall not exceed\u00a0\u00b10.001%URL\/V<\/td>\n<\/tr>\n<tr>\n<td>Signal de sortie<\/td>\n<td>4mA~20mADC+HART<\/p>\n<p>Modbus-RTU\/RS485<\/td>\n<\/tr>\n<tr>\n<td>Protection Grade<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Gamme<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Type de capteur<\/th>\n<th>Measuring Range degrees C<\/th>\n<th>Minimum Measurable Range degrees C<\/th>\n<th>Measurement Accuracy (whichever is greater) degrees C<\/th>\n<\/tr>\n<tr>\n<td>Pt100<\/td>\n<td>-200~600<\/td>\n<td>50<\/td>\n<td>\u00b10.2% range or \u00b10.2<\/td>\n<\/tr>\n<tr>\n<td>Pt1000<\/td>\n<td>-200~350<\/td>\n<td>50<\/td>\n<td>\u00b10.2% range or \u00b10.2<\/td>\n<\/tr>\n<tr>\n<td>K<\/td>\n<td>-230~1370<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>N<\/td>\n<td>-200~1300<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>-200~1000<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>J<\/td>\n<td>-210~1200<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>T<\/td>\n<td>-200~400<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>R<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td>S<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>0~1820<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"4\">Note: cold-junction compensation error must also be added during thermocouple measurement (internal cold-junction error &lt;0.5 degrees C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Conditions environnementales<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td>Article<\/td>\n<td colspan=\"2\">Condition<\/td>\n<\/tr>\n<tr>\n<td>Plage de temp\u00e9rature ambiante de fonctionnement<\/td>\n<td colspan=\"2\">-40 degr\u00e9s C ~ 85 degr\u00e9s C, \u00e9cran LCD : -20 degr\u00e9s C ~ 70 degr\u00e9s C<\/td>\n<\/tr>\n<tr>\n<td>Plage de temp\u00e9rature ambiante de stockage<\/td>\n<td colspan=\"2\">-40 degr\u00e9s C ~ 100 degr\u00e9s C, \u00e9cran LCD : -40 degr\u00e9s C ~ 85 degr\u00e9s C<\/td>\n<\/tr>\n<tr>\n<td>Plage d'humidit\u00e9 ambiante de fonctionnement<\/td>\n<td colspan=\"2\">5%RH~100%RH@40 degr\u00e9s C<\/td>\n<\/tr>\n<tr>\n<th>Zone dangereuse<\/th>\n<th>PCEC<\/th>\n<th>Certificate No.: CE19.2398X Certificate No.: CE19.3332<\/p>\n<p>Ex ia IIC T6 Ga Ex d IIC T6 Gb<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Environnement de compatibilit\u00e9 \u00e9lectromagn\u00e9tique<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Non.<\/th>\n<th>\u00c9l\u00e9ment d'essai<\/th>\n<th>Norme de base<\/th>\n<th>Condition d'essai<\/th>\n<th>Niveau de performance<\/th>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Perturbation rayonn\u00e9e (Enclos)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>30 MHz-1000 MHz<\/td>\n<td>B (Note 2)<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Perturbation conduite (port d'alimentation CC)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>0,15 MHz-30 MHz<\/td>\n<td>B (Note 2)<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Immunit\u00e9 de d\u00e9charge \u00e9lectrostatique (ESD)<\/td>\n<td>GB\/T 17626.2\/IEC61000-4-2<\/td>\n<td>4kV (contact), 8kV (air)<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Immunit\u00e9 du champ \u00e9lectromagn\u00e9tique RF<\/td>\n<td>GB\/T 17626.3\/IEC61000-4-3<\/td>\n<td>10 V\/m (80 MHz-1 GHz)<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Immunit\u00e9 de champ magn\u00e9tique de fr\u00e9quence de puissance<\/td>\n<td>GB\/T 17626.8\/IEC61000-4-8<\/td>\n<td>30A\/m<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Immunit\u00e9 \u00e9lectrique de passage rapide\/Burst<\/td>\n<td>GB\/T 17626.4\/IEC61000-4-4<\/td>\n<td>2kV (5\/50ns, 100 kHz)<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Surgir l'immunit\u00e9<\/td>\n<td>GB\/T 17626.5\/IEC61000-4-5<\/td>\n<td>4kV (ligne \u00e0 ligne)<\/p>\n<p>2kV (ligne-sol)<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Immunit\u00e9 de perturbation provoqu\u00e9e par les champs RF<\/td>\n<td>GB\/T 17626.6\/IEC61000-4-6<\/td>\n<td>3V (150 kHz-80 MHz)<\/td>\n<td>A (Note 1)<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Note 1 : Pour le niveau de performance A, les performances restent normales dans les limites des sp\u00e9cifications techniques<\/p>\n<p>Note 2 : Pour le niveau de performance B, la fonction ou les performances peuvent diminuer temporairement ou \u00eatre perdues, mais peuvent se r\u00e9tablir automatiquement, l'\u00e9tat de fonctionnement r\u00e9el, le stockage et les donn\u00e9es restent inchang\u00e9s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Alimentation et conditions de charge<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Article<\/th>\n<th>Condition de fonctionnement<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Tension d'alimentation<\/td>\n<td colspan=\"2\">Protocole de communication HART : 16.5 V~36 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Version intrins\u00e8quement s\u00fbre : protocole de communication HART : 18.5 V~28 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Modbus-RTU\/RS485 : 12 V ~ 36 V CC<\/td>\n<\/tr>\n<tr>\n<td>R\u00e9sistance de charge<\/td>\n<td colspan=\"2\">0Q~2119Q pendant l'op\u00e9ration<\/p>\n<p>250 ~ 600Q pour la communication HART<\/td>\n<\/tr>\n<tr>\n<td>Distance de transmission<\/td>\n<td colspan=\"2\">&lt; 1000m<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Consommation d'\u00e9nergie<\/td>\n<\/tr>\n<tr>\n<td>4mA~20mA<\/td>\n<td colspan=\"2\">&lt;= 500 mW@24V DC, 20,8 mA<\/td>\n<\/tr>\n<tr>\n<td>Modbus-RTU\/RS485<\/td>\n<td colspan=\"2\">&lt;= 240 mW@24V DC, 10 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The ADDA-T-GY Series temperature transmitter uses thermocouple or RTD sensing to measure, transmit, and display the temperature of solid surfaces, liquids, and gases. It supports digital cold-junction compensation, nonlinear correction, and local or remote parameter adjustment through HART communication.<\/p>","protected":false},"featured_media":438,"template":"","meta":{"rank_math_title":"ADDA Temperature Transmitter | RTD and Thermocouple Inputs","rank_math_description":"Explore the temperature transmitter with two-wire 4 to 20 mA output and HART communication for local or remote setup and process monitoring.","rank_math_canonical_url":"","rank_math_focus_keyword":"Temperature Transmitter"},"product_brand":[],"product_cat":[24,42],"product_tag":[],"class_list":["post-440","product","type-product","status-publish","has-post-thumbnail","product_cat-smart-industrial-transmitters","product_cat-temperature-transmitters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/product\/440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/media\/438"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/media?parent=440"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/product_brand?post=440"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/product_cat?post=440"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/product_tag?post=440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}