{"id":4133,"date":"2026-11-19T08:00:00","date_gmt":"2026-11-19T08:00:00","guid":{"rendered":"https:\/\/www.addameter.com\/?p=4133"},"modified":"2026-10-16T03:48:40","modified_gmt":"2026-10-16T03:48:40","slug":"intrinsically-safe-pressure-transmitter-reviewing-the-loop-as-a-system","status":"publish","type":"post","link":"https:\/\/www.addameter.com\/fr\/intrinsically-safe-pressure-transmitter-reviewing-the-loop-as-a-system\/","title":{"rendered":"Intrinsically Safe Pressure Transmitter: Reviewing the Loop as a System"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>Table des mati\u00e8res<\/h2><nav><ul><li class=\"\"><a href=\"#intrinsically-safe-pressure-transmitter-measurement-basis\">Intrinsically safe pressure transmitter: measurement basis<\/a><\/li><li class=\"\"><a href=\"#range-and-operating-envelope\">Gamme et enveloppe de fonctionnement<\/a><\/li><li class=\"\"><a href=\"#medium-and-material-review\">Examen moyen et mat\u00e9riel<\/a><\/li><li class=\"\"><a href=\"#intrinsically-safe-pressure-transmitter-installation-details\">Intrinsically safe pressure transmitter: installation details<\/a><\/li><li class=\"\"><a href=\"#signal-and-configuration\">Signal et configuration<\/a><\/li><li class=\"\"><a href=\"#intrinsically-safe-pressure-transmitter-verification-plan\">Intrinsically safe pressure transmitter: verification plan<\/a><\/li><li class=\"\"><a href=\"#maintenance-and-fault-checks\">Maintenance et contr\u00f4les des pannes<\/a><\/li><li class=\"\"><a href=\"#intrinsically-safe-pressure-transmitter-specification-for-adda\">Intrinsically safe pressure transmitter: specification for ADDA<\/a><\/li><li class=\"\"><a href=\"#practical-review-reviewing-the-loop-as-a-system\">Practical review: Reviewing the Loop as a System<\/a><\/li><li class=\"\"><a href=\"#technology-and-configuration-comparison\">Comparaison de technologie et de configuration<\/a><\/li><li class=\"\"><a href=\"#frequently-asked-questions\">Questions fr\u00e9quemment pos\u00e9es<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Intrinsically safe pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on reviewing the Loop as a System in a process pipeline feeding a packaged industrial skid. The aim is to verify the exact approved assembly and its installation conditions and turn that review into a configuration that can be installed, checked and maintained.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les ing\u00e9nieurs et les \u00e9quipes d'achat, le point de d\u00e9part utile est la valeur du processus \u00e0 laquelle il faut faire confiance, les conditions qui peuvent le rendre erron\u00e9 et les preuves n\u00e9cessaires avant l'acceptation L'examen suivant relie la m\u00e9thode de d\u00e9tection \u00e0 l'installation physique et au syst\u00e8me de r\u00e9ception Les exemples num\u00e9riques sont des calculs illustratifs, tandis que les limites et options finales du mod\u00e8le doivent \u00eatre confirm\u00e9es pour l'assemblage command\u00e9.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg\" alt=\"ADDA pressure instrument with local digital display\" class=\"wp-image-1152\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"intrinsically-safe-pressure-transmitter-measurement-basis\">Intrinsically safe pressure transmitter: measurement basis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The intrinsically safe pressure transmitter review should establish one consistent physical basis. Identify power supply, signal type and active or passive connection roles. A two-wire loop, separately powered output and digital bus require different wiring arrangements. Use the exact terminal diagram for the selected configuration.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"range-and-operating-envelope\">Gamme et enveloppe de fonctionnement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La dur\u00e9e de fonctionnement doit couvrir la lecture utile la plus basse et la condition normale la plus \u00e9lev\u00e9e Les pointes de d\u00e9marrage, la pression de nettoyage et l'isolement accidentel peuvent imposer des exigences diff\u00e9rentes La plage de mesure, la surcharge admissible et la limite de pression sont des quantit\u00e9s distinctes ; une port\u00e9e \u00e9lectrique plus grande ne peut compenser une cote m\u00e9canique inad\u00e9quate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For intrinsically safe pressure transmitter, the selected endpoints need a documented operating basis. Compare the exact marking and permitted conditions for the ordered assembly. Gas or dust group, temperature classification, ambient range and any special conditions need review where applicable. Do not combine approvals from different product versions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"medium-and-material-review\">Examen moyen et mat\u00e9riel<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The diaphragm, process fitting, gasket and any isolation valve form a wetted assembly. Stainless steel housing does not identify the diaphragm alloy or seal material. Review the medium composition, concentration and temperature together, particularly where cleaning chemicals differ from the normal process fluid.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A intrinsically safe pressure transmitter specification needs the actual exposure conditions. Keep material, connection and option details alongside the tag. Where certificates or declarations are required, retain the applicable document identity and scope rather than a generic claim.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"intrinsically-safe-pressure-transmitter-installation-details\">Intrinsically safe pressure transmitter: installation details<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choisissez un robinet qui communique une pression repr\u00e9sentative du processus sans effets excessifs de vibration ou de vitesse locale Planifiez le retrait de l'instrument et l'isolement s\u00e9curitaire avant d'installer le raccord Les poches de gaz en service liquide et le condensat en service gazeux peuvent modifier la pression apparente ou ralentir la r\u00e9ponse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The installed intrinsically safe pressure transmitter should follow the accepted application drawing. Store the final drawing or measured arrangement. Installation offsets, probe lengths, routes and process tap positions should remain recoverable after personnel or suppliers change.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg\" alt=\"ADDA differential pressure transmitter with two process connections\" class=\"wp-image-1155\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"signal-and-configuration\">Signal et configuration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For intrinsically safe pressure transmitter, the receiving value must retain the intended interpretation. For an intrinsically safe arrangement, review the complete circuit and associated equipment rather than only the field transmitter. Interface and power choices can affect the protection basis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"intrinsically-safe-pressure-transmitter-verification-plan\">Intrinsically safe pressure transmitter: verification plan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A intrinsically safe pressure transmitter acceptance check needs a reproducible comparison. Agree the acceptance evidence before ordering. Identify dimensional checks, configuration records and functional comparisons that demonstrate the requirements relevant to the project.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"maintenance-and-fault-checks\">Maintenance et contr\u00f4les des pannes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The intrinsically safe pressure transmitter service record should explain the observed condition. During maintenance, preserve the approved configuration and follow the equipment&#x27;s service conditions. Unreviewed component, battery, gland or interface changes can alter the assembly&#x27;s suitability.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"intrinsically-safe-pressure-transmitter-specification-for-adda\">Intrinsically safe pressure transmitter: specification for ADDA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A intrinsically safe pressure transmitter inquiry is strongest when its assumptions are explicit. Retain the wiring diagram and observed signal values with the configuration record. This gives maintenance a repeatable starting point when the instrument is replaced or the receiving channel changes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00e9viser le <a href=\"https:\/\/www.addameter.com\/fr\/produit\/smart-gauge-absolute-pressure-transmitter\/\">Informations de configuration de l'\u00e9metteur de pression intelligent\/absolu<\/a> et le <a href=\"https:\/\/www.addameter.com\/fr\/products\/\">Portefeuille de produits ADDA<\/a> \u00e0 c\u00f4t\u00e9 de la feuille de balises Ces liens identifient la famille de produits pertinente ; ils ne remplacent pas la confirmation des mat\u00e9riaux, interfaces et limites de fonctionnement ordonn\u00e9s exacts.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"practical-review-reviewing-the-loop-as-a-system\">Practical review: Reviewing the Loop as a System<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pour une port\u00e9e de jauge illustrative de 10 bars, 12 mA repr\u00e9sente 5 bars lorsque la sortie est lin\u00e9aire Un \u00e9metteur sur une port\u00e9e de 0,1 bar donne 8 bar au m\u00eame courant Ce sont des exemples de calcul, pas des notes de mod\u00e8le.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To apply this example to intrinsically safe pressure transmitter, begin with the actual drawing and collect the inputs that reviewing the Loop as a System requires. Mark each input as measured, specified or still awaiting confirmation. Compare the result with the normal operating point, then repeat the review at the relevant low or high condition. This makes an assumption visible before it becomes an unexplained offset in the control system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un examen pratique devrait laisser trois enregistrements utilisables : la disposition physique qui a \u00e9t\u00e9 v\u00e9rifi\u00e9e, la configuration qui met en \u0153uvre l'interpr\u00e9tation pr\u00e9vue et les observations utilis\u00e9es pour juger du r\u00e9sultat Si l'un de ces changements, identifier quelles conclusions doivent \u00eatre r\u00e9p\u00e9t\u00e9es Ceci est particuli\u00e8rement utile lorsqu'un instrument de remplacement a le m\u00eame nom de famille mais une gamme, connexion, sonde, sortie ou option \u00e9lectronique diff\u00e9rente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"technology-and-configuration-comparison\">Comparaison de technologie et de configuration<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Option<\/th><th>Consid\u00e9ration d'application<\/th><th>Preuve \u00e0 demander<\/th><\/tr><\/thead><tbody><tr><td>Mesure de jauge<\/td><td>r\u00e9f\u00e9rence atmosph\u00e9rique et pression ordinaire de la conduite<\/td><td>Site requirement supplied by responsible owner<\/td><\/tr><tr><td>Mesure absolue<\/td><td>r\u00e9f\u00e9rence du vide et calculs de pression<\/td><td>Exact marking and conditions reviewed<\/td><\/tr><tr><td>Mesure diff\u00e9rentielle<\/td><td>deux points de processus et des t\u00e2ches de chute de pression<\/td><td>Complete installed assembly inspected<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use this comparison to structure a intrinsically safe pressure transmitter review, rather than to rank every technology for every process. The preferred option is the one that meets the required measurement task within the available installation and maintenance conditions. Compare supplier offers against the same operating envelope and ask for explicit exceptions when an option cannot meet one of the requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un contexte ind\u00e9pendant, consultez <a href=\"https:\/\/www.nist.gov\/programs-projects\/pressurevacuum-calibrations\" target=\"_blank\" rel=\"noopener\">informations d\u2019\u00e9talonnage de la pression et du vide du NIST<\/a>. Cette r\u00e9f\u00e9rence fournit un contexte technique ou m\u00e9trologique g\u00e9n\u00e9ral Il n'est pas prouv\u00e9 qu'un produit ADDA particulier a \u00e9t\u00e9 certifi\u00e9, approuv\u00e9 ou \u00e9talonn\u00e9 par cet organisme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Discuss your intrinsically safe pressure transmitter application with ADDA.<\/strong> Send the operating data and drawing through the form below, including the specific issue of reviewing the Loop as a System. Request a configuration review, the relevant product information and confirmation of any outstanding application assumptions before placing the order.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-25-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Intrinsically safe pressure transmitter: does an intrinsically safe field device establish a safe loop?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>The field device is one part of the circuit. Associated equipment, cable parameters and the selected connection arrangement must be reviewed together against the applicable documentation by the responsible project engineer. A product label alone is insufficient.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-25-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Intrinsically safe pressure transmitter: can any barrier be used with the transmitter?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>The barrier or isolator must be compatible with the approved circuit parameters and installation design. Compare the exact equipment documentation, supply and signal requirements. Do not assume that two devices using a 4\u201320 mA interface automatically form a suitable protected system.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-25-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Intrinsically safe pressure transmitter: why is cable information relevant?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Cable electrical parameters can form part of the circuit assessment. Cable length and type also influence signal and supply performance. Preserve both the protection design information and the ordinary measurement-loop calculation in the project record.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-25-4\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Intrinsically safe pressure transmitter: what changes require renewed review?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>A replacement barrier, output option, cable arrangement or power source can affect the circuit basis. Check the proposed change against the exact approved documentation before treating it as an equivalent replacement. Follow the site&#x27;s engineering change procedure.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-25-5\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Intrinsically safe pressure transmitter: which evidence should accompany the purchase?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Request the precise model marking, applicable documentation, special conditions and terminal information for the offered configuration. Tie these records to the tag and have the responsible engineer confirm their applicability to the site&#x27;s classified location.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class='fluentform ff-default fluentform_wrapper_3 ffs_default_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" action=\"\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u5b98\u7f51\u8be2\u76d8<\/legend>        <div\n                style=\"display: none!important; position: absolute!important; transform: translateX(1000%)!important;\"\n                class=\"ff-el-group ff-hpsf-container\"\n        >\n            <div class=\"ff-el-input--label asterisk-right\">\n                <label for=\"ff_3_item_sf\" aria-label=\"Notifier\">\n                    Notifier                <\/label>\n            <\/div>\n            <div class=\"ff-el-input--content\">\n                <input type=\"text\"\n                       name=\"item_3__fluent_sf\"\n                       class=\"ff-el-form-control\"\n                       id=\"ff_3_item_sf\"\n                \/>\n            <\/div>\n        <\/div>\n        <input type='hidden' name='__fluent_form_embded_post_id' value='4133' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"c78be36fad\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/fr\/wp-json\/wp\/v2\/posts\/4133\" \/><div data-name=\"ff_cn_id_1\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_input_text' id='label_ff_3_input_text' aria-label=\"Nom\">Nom<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text\" class=\"ff-el-form-control\" placeholder=\"Nom\" data-name=\"input_text\" id=\"ff_3_input_text\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_subject' id='label_ff_3_subject' aria-label=\"T\u00e9l\u00e9phone\">T\u00e9l\u00e9phone<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"T\u00e9l\u00e9phone\" data-name=\"subject\" id=\"ff_3_subject\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email' aria-label=\"Courriel\">Courriel<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"Adresse e-mail\" data-name=\"email\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_message' id='label_ff_3_message' aria-label=\"Votre Message\">Votre Message<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_3_message\" name=\"message\" id=\"ff_3_message\" class=\"ff-el-form-control\" placeholder=\"Votre Message\" rows=\"5\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Soumettre Formulaire\">Soumettre Formulaire<\/button><\/div><\/fieldset><input type=\"hidden\" name=\"trp-form-language\" value=\"fr\"\/><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/www.addameter.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"input_text\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>","protected":false},"excerpt":{"rendered":"<p>Intrinsically safe pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on reviewing the Loop as a System in a process pipeline feeding a packaged industrial skid. The aim is to verify the exact approved assembly and its installation conditions and turn that review into a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1152,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Intrinsically safe pressure transmitter | ADDA Guide","rank_math_description":"Intrinsically safe pressure transmitter: reviewing the Loop as a System. Review practical selection, installation and verification points with ADDA.","rank_math_canonical_url":"https:\/\/www.addameter.com\/intrinsically-safe-pressure-transmitter-reviewing-the-loop-as-a-system\/","rank_math_focus_keyword":"intrinsically safe pressure transmitter"},"categories":[22],"tags":[],"class_list":["post-4133","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/posts\/4133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/comments?post=4133"}],"version-history":[{"count":1,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/posts\/4133\/revisions"}],"predecessor-version":[{"id":4145,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/posts\/4133\/revisions\/4145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/media\/1152"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/media?parent=4133"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/categories?post=4133"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/fr\/wp-json\/wp\/v2\/tags?post=4133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}