{"id":440,"date":"2026-07-07T01:54:40","date_gmt":"2026-07-07T01:54:40","guid":{"rendered":"https:\/\/addameter.com\/product\/temperature-transmitter\/"},"modified":"2026-10-21T04:02:23","modified_gmt":"2026-10-21T04:02:23","slug":"temperature-transmitter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/es\/producto\/temperature-transmitter\/","title":{"rendered":"Transmisor de temperatura"},"content":{"rendered":"<style>\n.adda-product-description{font-size:15px;line-height:1.72;color:#4b5563}<br \/>.adda-product-description strong{color:#111827}<br \/>.adda-table-wrap{width:100%;overflow-x:auto;margin:18px 0 26px;border:1px solid #e5e7eb;border-radius:6px;background:#fff}<br \/>.adda-spec-table{width:100%;min-width:720px;border-collapse:collapse;margin:0;font-size:14px;line-height:1.55}<br \/>.adda-spec-table th,.adda-spec-table td{border:1px solid #e5e7eb;padding:11px 14px;vertical-align:top;text-align:left}<br \/>.adda-spec-table th{background:#f6f7f9;color:#111827;font-weight:700}<br \/>.adda-spec-table td:first-child{color:#111827;font-weight:600}<br \/>.adda-spec-table tr:nth-child(even) td{background:#fafafa}<br \/>.adda-spec-table p{margin:0 0 6px}<br \/>.adda-spec-table p:last-child{margin-bottom:0}<br \/>.adda-spec-note{background:#fff8f4!important;color:#374151!important;font-weight:400!important}<br \/>@media (max-width:767px){.adda-product-description{font-size:14px}.adda-spec-table{min-width:680px;font-size:13px}.adda-spec-table th,.adda-spec-table td{padding:9px 11px}}<br \/><\/style>\n<div class=\"adda-product-description\">\n<h3>Transmisor de temperatura<\/h3>\n<p><strong>Caracter\u00edsticas del producto<\/strong><\/p>\n<p>The ADDA-T-GY Series thermocouple and RTD temperature transmitter measures, transmits, and displays the temperature of solid surfaces, liquids, and gases. Key features include:<\/p>\n<ul>\n<li>Sellado con caucho de silicona o resina epoxi para resistencia a vibraciones y humedad; adecuado para entornos operativos hostiles.<\/li>\n<li>Alta precisi\u00f3n, bajo consumo de energ\u00eda en reposo, funcionamiento estable y confiable y larga vida \u00fatil.<\/li>\n<li>Two-wire 4mA.dc.~20mA.dc output with strong interference resistance and long transmission distance.<\/li>\n<li>Digital cold-junction compensation and nonlinear correction.<\/li>\n<li>Intrinsically safe and flameproof versions for installation in Zone 0, Zone 1, Zone 2, and other hazardous areas.<\/li>\n<li>The digital display orientation can be adjusted to suit installation requirements. It displays measured temperature, output current, and percentage in real time.<\/li>\n<li>HART communication supports local or remote parameter adjustment and monitoring through a handheld communicator.<\/li>\n<\/ul>\n<p><strong>Aplicaciones<\/strong><\/p>\n<p>Temperature measurement in petroleum, chemical, metallurgical, electric power, and other industries.<\/p>\n<p><strong>Medio de medici\u00f3n<\/strong><\/p>\n<p>Medios compatibles con los materiales humedecidos.<\/p>\n<p><strong>Especificaciones de rendimiento<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Precisi\u00f3n<\/th>\n<th>\u00b10.1%, \u00b10.2%, 0.5% L\u00edmite de rango superior, consulte las especificaciones para obtener m\u00e1s detalles<\/th>\n<\/tr>\n<tr>\n<td>Rango<\/td>\n<td>-230~1820 degrees C, see selection table for details<\/td>\n<\/tr>\n<tr>\n<td>Estabilidad Anual<\/td>\n<td>\u00b10.1% Span\/2 years<\/td>\n<\/tr>\n<tr>\n<td>Influencia de voltaje<\/td>\n<td>Cuando el voltaje de suministro var\u00eda dentro de 10,5 V\/16,5 V~36 V CC, los cambios en el punto cero y la luz no exceder\u00e1n \u00b10,001%URL\/V<\/td>\n<\/tr>\n<tr>\n<td>Se\u00f1al de salida<\/td>\n<td>4mA~20mADC+HART<\/p>\n<p>Modbus-RTU\/RS485<\/td>\n<\/tr>\n<tr>\n<td>Grado de protecci\u00f3n<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Rango<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Tipo de sensor<\/th>\n<th>Grados del rango de medici\u00f3n C<\/th>\n<th>Grados de rango m\u00ednimo medible C<\/th>\n<th>Precisi\u00f3n de medici\u00f3n (la que sea mayor) grados C<\/th>\n<\/tr>\n<tr>\n<td>Pt100<\/td>\n<td>-200~600<\/td>\n<td>50<\/td>\n<td>Rango \u00b10,2% o \u00b10,2<\/td>\n<\/tr>\n<tr>\n<td>Pt1000<\/td>\n<td>-200~350<\/td>\n<td>50<\/td>\n<td>Rango \u00b10,2% o \u00b10,2<\/td>\n<\/tr>\n<tr>\n<td>K<\/td>\n<td>-230~1370<\/td>\n<td>100<\/td>\n<td>Rango \u00b10,1% o \u00b10,5<\/td>\n<\/tr>\n<tr>\n<td>N<\/td>\n<td>-200~1300<\/td>\n<td>100<\/td>\n<td>Rango \u00b10,1% o \u00b10,5<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>-200~1000<\/td>\n<td>100<\/td>\n<td>Rango \u00b10,1% o \u00b10,5<\/td>\n<\/tr>\n<tr>\n<td>J<\/td>\n<td>-210~1200<\/td>\n<td>100<\/td>\n<td>Rango \u00b10,1% o \u00b10,5<\/td>\n<\/tr>\n<tr>\n<td>T<\/td>\n<td>-200~400<\/td>\n<td>100<\/td>\n<td>Rango \u00b10,1% o \u00b10,5<\/td>\n<\/tr>\n<tr>\n<td>R<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>Rango \u00b10,1% o \u00b11<\/td>\n<\/tr>\n<tr>\n<td>S<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>Rango \u00b10,1% o \u00b11<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>0~1820<\/td>\n<td>200<\/td>\n<td>Rango \u00b10,1% o \u00b11<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"4\">Nota: tambi\u00e9n se debe agregar un error de compensaci\u00f3n de la uni\u00f3n en fr\u00edo durante la medici\u00f3n del termopar (error interno de la uni\u00f3n en fr\u00edo &lt;0,5 grados C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Condiciones ambientales<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td>Art\u00edculo<\/td>\n<td colspan=\"2\">Condici\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Rango de temperatura ambiente de funcionamiento<\/td>\n<td colspan=\"2\">-40 grados C ~ 85 grados C, pantalla LCD: -20 grados C ~ 70 grados C<\/td>\n<\/tr>\n<tr>\n<td>Rango de temperatura ambiente de almacenamiento<\/td>\n<td colspan=\"2\">-40 grados C ~ 100 grados C, pantalla LCD: -40 grados C ~ 85 grados C<\/td>\n<\/tr>\n<tr>\n<td>Rango de humedad ambiental operativa<\/td>\n<td colspan=\"2\">5%RH~100%RH@40 grados C<\/td>\n<\/tr>\n<tr>\n<th>Zona peligrosa<\/th>\n<th>PCEC<\/th>\n<th>Certificate No.: CE19.2398X Certificate No.: CE19.3332<\/p>\n<p>Ex ia IIC T6 Ga Ex d IIC T6 Gb<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Entorno de compatibilidad electromagn\u00e9tica<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>No.<\/th>\n<th>Art\u00edculo de prueba<\/th>\n<th>Est\u00e1ndar b\u00e1sico<\/th>\n<th>Condici\u00f3n de prueba<\/th>\n<th>Nivel de rendimiento<\/th>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Perturbaci\u00f3n Radiada (Recinto)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>30MHz-1000MHz<\/td>\n<td>B (Nota 2)<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Perturbaci\u00f3n conducida (puerto de alimentaci\u00f3n de CC)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>0,15MHz-30MHz<\/td>\n<td>B (Nota 2)<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Inmunidad de descarga electrost\u00e1tica (ESD)<\/td>\n<td>GB\/T 17626.2\/IEC61000-4-2<\/td>\n<td>4kV (contacto), 8kV (aire)<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Inmunidad de campo electromagn\u00e9tico de RF<\/td>\n<td>GB\/T 17626.3\/IEC61000-4-3<\/td>\n<td>10V\/m (80MHz-1GHz)<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Inmunidad de campo magn\u00e9tico de frecuencia de potencia<\/td>\n<td>GB\/T 17626.8\/IEC61000-4-8<\/td>\n<td>30A\/m<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Inmunidad el\u00e9ctrica transitoria r\u00e1pida\/explosi\u00f3n<\/td>\n<td>GB\/T 17626.4\/IEC61000-4-4<\/td>\n<td>2kV (5\/50ns, 100kHz)<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Inmunidad de aumento<\/td>\n<td>GB\/T 17626.5\/IEC61000-4-5<\/td>\n<td>4kV (l\u00ednea a l\u00ednea)<\/p>\n<p>2kV (l\u00ednea a tierra)<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Inmunidad por perturbaci\u00f3n conducida inducida por campos de RF<\/td>\n<td>GB\/T 17626.6\/IEC61000-4-6<\/td>\n<td>3V (150kHz-80MHz)<\/td>\n<td>A (Nota 1)<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Nota 1: Para el nivel de rendimiento A, el rendimiento sigue siendo normal dentro de los l\u00edmites de las especificaciones t\u00e9cnicas<\/p>\n<p>Nota 2: Para el nivel de rendimiento B, la funci\u00f3n o el rendimiento pueden disminuir temporalmente o perderse, pero pueden recuperarse autom\u00e1ticamente; el estado operativo real, el almacenamiento y los datos permanecen sin cambios<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Condiciones de suministro de energ\u00eda y carga<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Art\u00edculo<\/th>\n<th>Condici\u00f3n operativa<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Voltaje de la fuente de alimentaci\u00f3n<\/td>\n<td colspan=\"2\">Protocolo de comunicaci\u00f3n HART: 16,5V~36V CC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Versi\u00f3n intr\u00ednsecamente segura: protocolo de comunicaci\u00f3n HART: 18,5V~28V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Modbus-RTU\/RS485: 12V~36V CC<\/td>\n<\/tr>\n<tr>\n<td>Resistencia a la carga<\/td>\n<td colspan=\"2\">000~21190 durante la operaci\u00f3n<\/p>\n<p>2501~6000 para comunicaci\u00f3n HART<\/td>\n<\/tr>\n<tr>\n<td>Distancia de transmisi\u00f3n<\/td>\n<td colspan=\"2\">&lt; 1000m<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Consumo de energ\u00eda<\/td>\n<\/tr>\n<tr>\n<td>4mA~20mA<\/td>\n<td colspan=\"2\">&lt;= 500mW@24V DC, 20,8mA<\/td>\n<\/tr>\n<tr>\n<td>Modbus-RTU\/RS485<\/td>\n<td colspan=\"2\">&lt;= 240mW@24V DC, 10mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>El transmisor de temperatura de la serie ADDA-T-GY utiliza sensores de termopar o RTD para medir, transmitir y mostrar la temperatura de superficies s\u00f3lidas, l\u00edquidos y gases. Admite compensaci\u00f3n digital de uni\u00f3n fr\u00eda, correcci\u00f3n no lineal y ajuste de par\u00e1metros locales o remotos a trav\u00e9s de comunicaci\u00f3n HART.<\/p>","protected":false},"featured_media":438,"template":"","meta":{"rank_math_title":"ADDA Temperature Transmitter | RTD and Thermocouple Inputs","rank_math_description":"Explore the temperature transmitter with two-wire 4 to 20 mA output and HART communication for local or remote setup and process monitoring.","rank_math_canonical_url":"","rank_math_focus_keyword":"Temperature Transmitter"},"product_brand":[],"product_cat":[24,42],"product_tag":[],"class_list":["post-440","product","type-product","status-publish","has-post-thumbnail","product_cat-smart-industrial-transmitters","product_cat-temperature-transmitters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/product\/440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/media\/438"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/media?parent=440"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/product_brand?post=440"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/product_cat?post=440"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/es\/wp-json\/wp\/v2\/product_tag?post=440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}