{"id":814,"date":"2026-07-13T02:48:01","date_gmt":"2026-07-13T02:48:01","guid":{"rendered":"https:\/\/addameter.com\/product\/sanitary-absolute-pressure-transmitter-757\/"},"modified":"2026-10-21T04:01:55","modified_gmt":"2026-10-21T04:01:55","slug":"sanitary-absolute-pressure-transmitter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/de\/produkt\/sanitary-absolute-pressure-transmitter\/","title":{"rendered":"Sanit\u00e4r-Absolutdrucksender"},"content":{"rendered":"<style>\n.adda-product-description{font-size:15px;line-height:1.72;color:#4b5563}<br \/>.adda-product-description strong{color:#111827}<br \/>.adda-table-wrap{width:100%;overflow-x:auto;margin:18px 0 26px;border:1px solid #e5e7eb;border-radius:6px;background:#fff}<br \/>.adda-spec-table{width:100%;min-width:720px;border-collapse:collapse;margin:0;font-size:14px;line-height:1.55}<br \/>.adda-spec-table th,.adda-spec-table td{border:1px solid #e5e7eb;padding:11px 14px;vertical-align:top;text-align:left}<br \/>.adda-spec-table th{background:#f6f7f9;color:#111827;font-weight:700}<br \/>.adda-spec-table td:first-child{color:#111827;font-weight:600}<br \/>.adda-spec-table tr:nth-child(even) td{background:#fafafa}<br \/>.adda-spec-table p{margin:0 0 6px}<br \/>.adda-spec-table p:last-child{margin-bottom:0}<br \/>.adda-spec-note{background:#fff8f4!important;color:#374151!important;font-weight:400!important}<br \/>@media (max-width:767px){.adda-product-description{font-size:14px}.adda-spec-table{min-width:680px;font-size:13px}.adda-spec-table th,.adda-spec-table td{padding:9px 11px}}<br \/><\/style>\n<div class=\"adda-product-description\">\n<h3>Sanit\u00e4r-Absolutdrucksender<\/h3>\n<p><strong>Produktmerkmale<\/strong><\/p>\n<p>The ADDA-P-1GW smart flush diaphragm pressure transmitter is designed for sanitary applications in food, beverage, pharmaceutical, and bioengineering industries. It features an all-stainless-steel structure and a dot-matrix LCD module that supports 355\u00b0 rotation. The hygienic design has no dead spaces and is designed to comply with FDA requirements.<\/p>\n<ul>\n<li>Uses monocrystalline silicon piezoresistive technology for stable performance, with accuracy up to 0.1%F.S.<\/li>\n<li>Hygienisches Design entspricht den Anforderungen von EHEDG, 3 A, FDA und GMP.<\/li>\n<li>Oberfl\u00e4chenrauheit des benetzten Materials bis Ra 0,4<\/li>\n<li>Unterst\u00fctzt die CIP-SIP-Reinigung mit einer Temperaturbest\u00e4ndigkeit von bis zu 150 Grad C<\/li>\n<li>Verwendet ein Hochleistungs-EMV-Schutzschaltungsmodul, um elektromagnetische St\u00f6rungen am Ausgang zu reduzieren.<\/li>\n<li>High stability: \u00b10.2% Span\/5 years<\/li>\n<\/ul>\n<p><strong>Anwendungen<\/strong><\/p>\n<p>Druck- und F\u00fcllstandsmessung in Lebensmitteln, Getr\u00e4nken, Pharmazeutika und anderen Sanit\u00e4ranwendungen.<\/p>\n<p><strong>Messmedium<\/strong><\/p>\n<p>Mit den benetzten Materialien kompatible Medien.<\/p>\n<p><strong>Leistungsspezifikationen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Genauigkeit<\/th>\n<th>\u00b10,11TP3 T, \u00b10,21TP3 T Obere Bereichsgrenze, Einzelheiten siehe Spezifikationen<\/th>\n<\/tr>\n<tr>\n<td>Reichweite<\/td>\n<td>10 kPa~40 MPa, Einzelheiten finden Sie in der Auswahltabelle<\/td>\n<\/tr>\n<tr>\n<td>J\u00e4hrliche Stabilit\u00e4t<\/td>\n<td>\u00b10,2% Spanne\/5 Jahre<\/td>\n<\/tr>\n<tr>\n<td>Einfluss der Umgebungstemperatur<\/td>\n<td>Einzelheiten siehe Spezifikationen<\/td>\n<\/tr>\n<tr>\n<td>Spannungseinfluss<\/td>\n<td>Wenn die Versorgungsspannung innerhalb von 10,5 V\/16,5 V~36 V DC variiert, d\u00fcrfen die \u00c4nderungen des Nullpunkts und der Spannweite \u00b10,001%URL\/V nicht \u00fcberschreiten<\/td>\n<\/tr>\n<tr>\n<td>Einfluss auf die Montageposition<\/td>\n<td>Die Installation des Senders kann einen Nullfehler verursachen. Dieser Fehler kann durch Nullanpassung korrigiert werden, ohne dass sich dies auf die Genauigkeit auswirkt<\/td>\n<\/tr>\n<tr>\n<td>Vibrationseinfluss<\/td>\n<td>Getestet gem\u00e4\u00df GB\/T18271.3\/IEC61298-3-Test, &lt; 0,1%<\/td>\n<\/tr>\n<tr>\n<td>Ausgangssignal<\/td>\n<td>4 mA~20 mADC+HART<\/p>\n<p>Modbus-RTU\/RS485<\/td>\n<\/tr>\n<tr>\n<td>Schutzgrad<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Reichweite<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Drucktyp<\/th>\n<th>Nominalbereich<\/th>\n<th>Mindestreichweite<\/th>\n<th>Untere Bereichsgrenze (LRL)<\/th>\n<th>Obere Bereichsgrenze (URL)<\/th>\n<th>\u00dcberlast*<\/th>\n<\/tr>\n<tr>\n<td>G<\/td>\n<td>40 kPa<\/td>\n<td>10 kPa<\/td>\n<td>-40 kPa<\/td>\n<td>40 kPa<\/td>\n<td>1 MPa<\/td>\n<\/tr>\n<tr>\n<td>250 kPa<\/td>\n<td>25kPa<\/td>\n<td>-100 kPa<\/td>\n<td>250 kPa<\/td>\n<td colspan=\"2\">4 MPa<\/td>\n<\/tr>\n<tr>\n<td>1 MPa<\/td>\n<td>50 kPa<\/td>\n<td>-100 kPa<\/td>\n<td>1 MPa<\/td>\n<td colspan=\"2\">6 MPa<\/td>\n<\/tr>\n<tr>\n<td>3MPa<\/td>\n<td>150 kPa<\/td>\n<td>-0,1 MPa<\/td>\n<td>3MPa<\/td>\n<td colspan=\"2\">15 MPa<\/td>\n<\/tr>\n<tr>\n<td>10 MPa<\/td>\n<td>500 kPa<\/td>\n<td>-0,1 MPa<\/td>\n<td>10 MPa<\/td>\n<td colspan=\"2\">20 MPa<\/td>\n<\/tr>\n<tr>\n<td>40 MPa<\/td>\n<td>2MPa<\/td>\n<td>-0,1 MPa<\/td>\n<td>40 MPa<\/td>\n<td colspan=\"2\">80 MPa<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>40 kPa<\/td>\n<td>20 kPa<\/td>\n<td>0 kPa<\/td>\n<td>40 kPa<\/td>\n<td>1 MPa<\/td>\n<\/tr>\n<tr>\n<td>250 kPa<\/td>\n<td>50 kPa<\/td>\n<td>0 kPa<\/td>\n<td>250 kPa<\/td>\n<td colspan=\"2\">4 MPa<\/td>\n<\/tr>\n<tr>\n<td>1 MPa<\/td>\n<td>100 kPa<\/td>\n<td>0 kPa<\/td>\n<td>1 MPa<\/td>\n<td colspan=\"2\">6 MPa<\/td>\n<\/tr>\n<tr>\n<td>3MPa<\/td>\n<td>300 kPa<\/td>\n<td>0 kPa<\/td>\n<td>3MPa<\/td>\n<td colspan=\"2\">10 MPa<\/td>\n<\/tr>\n<tr>\n<td>10 MPa<\/td>\n<td>1 MPa<\/td>\n<td>0 kPa<\/td>\n<td>10 MPa<\/td>\n<td colspan=\"2\">20 MPa<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"6\">Anforderungen an die Festlegung hoher und niedriger Grenzwerte: Unterer Bereichswert (LRV) und oberer Bereichswert (URV) m\u00fcssen innerhalb der unteren und oberen Bereichsbegrenzung festgelegt werden, |URV-LRV|TROGHT Mindestbereich<\/p>\n<p>*Die \u00dcberlastwerte beziehen sich auf den maximalen \u00dcberlastbereich des Sensors, Der maximale \u00dcberlastbereich des Senders h\u00e4ngt letztlich von der Druckbewertung des Prozessanschlusses ab.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Genauigkeit<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Basierend auf Standards und Referenztestbedingungen, einschlie\u00dflich Best Fit Straight Line (BFSL), Hysterese, Wiederholbarkeit Kalibrierungstemperatur:20 Grad C \u00b15 Grad C.<\/td>\n<\/tr>\n<tr>\n<th>Lineare Ausgangsgenauigkeit<\/th>\n<th>G<\/th>\n<th>TD&lt;=5<\/th>\n<th>\u00b10,2%-Spanne<\/th>\n<th>40 kPa<\/th>\n<\/tr>\n<tr>\n<td>\u00b10,1%-Spanne<\/td>\n<td colspan=\"4\">250kPa\u00a0, 1\u00a0MPa, 3MPa, 10MPa, 40MPa<\/td>\n<\/tr>\n<tr>\n<td>TD&gt;5<\/td>\n<td>\u00b1 (0.005+0.045TD)\u00a0%\u00a0Span<\/td>\n<td colspan=\"3\">40 kPa<\/td>\n<\/tr>\n<tr>\n<td>\u00b1 (0.002+0.03TD)\u00a0%\u00a0Span<\/td>\n<td colspan=\"4\">250kPa, \u00a01\u00a0MPa, 3MPa, 10MPa, 40MPa<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>TD&lt;=5<\/td>\n<td>\u00b10,2%-Spanne<\/td>\n<td colspan=\"2\">40 kPa<\/td>\n<\/tr>\n<tr>\n<td>\u00b10,1%-Spanne<\/td>\n<td colspan=\"4\">250 kPa, 1 MPa, 3 MPa, 10 MPa<\/td>\n<\/tr>\n<tr>\n<td>TD&gt;5<\/td>\n<td>\u00b1 (0.005+0.05TD)\u00a0%\u00a0Span<\/td>\n<td colspan=\"3\">40 kPa<\/td>\n<\/tr>\n<tr>\n<td>\u00b1 (0.005+0.03TD)\u00a0%\u00a0Span<\/td>\n<td colspan=\"4\">250 kPa, 1 MPa, 3 MPa, 10 MPa<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Hinweis: TD (Downdown) bedeutet Turndown-Verh\u00e4ltnis, TD = maximale Reichweite\/Stromreichweite<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Einfluss der Umgebungstemperatur<\/strong><strong>\u00a0<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Drucktyp<\/th>\n<th>Beeinflussung der Menge<\/th>\n<th>Reichweite<\/th>\n<\/tr>\n<tr>\n<td>G<\/td>\n<td>\u00b1 (0.1+0.015TD)\u00a0%\u00a020 degrees C\u00a0of Span<\/td>\n<td>40kPa, 250kPa<\/p>\n<p>1 MPa, 3 MPa, 10 MPa, 40 MPa<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>\u00b1 (0.1+0.015TD)\u00a0%\u00a020 degrees C\u00a0of\u00a0Span<\/td>\n<td>40kPa, 250kPa<\/p>\n<p>1MPa, 3MPa, 10MPa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Umweltbedingungen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td>Artikel<\/td>\n<td colspan=\"2\">Bedingung<\/td>\n<\/tr>\n<tr>\n<td>Betriebsumgebungstemperaturbereich<\/td>\n<td colspan=\"2\">-40 Grad C ~85 Grad C, LCD-Display: -20 Grad C ~70 Grad C<\/td>\n<\/tr>\n<tr>\n<td>Speicherumgebungstemperaturbereich<\/td>\n<td colspan=\"2\">-40 Grad C ~100 Grad C, LCD-Display: -40 Grad C ~85 Grad C<\/td>\n<\/tr>\n<tr>\n<td>Gemessener mittlerer Temperaturbereich<\/td>\n<td colspan=\"2\">Sanit\u00e4rf\u00fcll\u00f6l: -20 Grad C ~150 Grad C<\/td>\n<\/tr>\n<tr>\n<td>Betriebsumgebungsfeuchtigkeitsbereich<\/td>\n<td colspan=\"2\">5%RH~100%RH@40 Grad C<\/td>\n<\/tr>\n<tr>\n<th>Gefahrenbereich<\/th>\n<th>PCEC<\/th>\n<th>Zertifikat Nr: CE20.2148 X Zertifikat Nr: CE23.0612X<\/p>\n<p>Ex ia IIC T6 Ga Ex db IIC T6 Gb<\/p>\n<p>Ex tb IIIC T80 Grad C Db<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Zeitangaben<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td>Gesamtd\u00e4mpfungszeitkonstante: entspricht der Summe aus D\u00e4mpfungszeitkonstante der elektronischen Schaltungskomponente und D\u00e4mpfungszeitkonstante der Sensorkapsel<\/td>\n<\/tr>\n<tr>\n<td>D\u00e4mpfungszeit der Komponenten elektronischer Schaltkreise: 0 s~99 s einstellbarer Bereich<\/td>\n<\/tr>\n<tr>\n<td>Gesamtansprechzeit: &lt;= 90 ms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Elektromagnetische Vertr\u00e4glichkeitsumgebung<\/strong><strong> (nur Stromsignal)<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Nein.<\/th>\n<th>Testgegenstand<\/th>\n<th>Grundstandard<\/th>\n<th>Testbedingung<\/th>\n<th>Leistungsniveau<\/th>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Strahlungsst\u00f6rung (Geh\u00e4use)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>30 MHz-1000 MHz<\/td>\n<td>B (Anmerkung 2)<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Durchgef\u00fchrte St\u00f6rung (DC Power Port)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>0,15 MHz-30 MHz<\/td>\n<td>B (Anmerkung 2)<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Immunit\u00e4t gegen elektrostatische Entladung (ESD)<\/td>\n<td>GB\/T 17626.2\/IEC61000-4-2<\/td>\n<td>4 kV (Kontakt), 8 kV (Luft)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Immunit\u00e4t gegen elektromagnetische HF-Felder<\/td>\n<td>GB\/T 17626.3\/IEC61000-4-3<\/td>\n<td>10 V\/m (80 MHz-1 GHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Immunit\u00e4t des magnetischen Feldes mit hoher Frequenz<\/td>\n<td>GB\/T 17626,8\/IEC61000-4-8<\/td>\n<td>30 A\/m<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Elektrische schnelle vor\u00fcbergehende\/Burst-Immunit\u00e4t<\/td>\n<td>GB\/T 17626.4\/IEC61000-4-4<\/td>\n<td>2 kV (5\/50 ns, 100 kHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Surge-immunit\u00e4t<\/td>\n<td>GB\/T 17626,5\/IEC61000-4-5<\/td>\n<td>4 kV (Line-to-Line)<\/p>\n<p>2 kV (line-to-ground)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Durch HF-Felder induzierte St\u00f6rungsimmunit\u00e4t<\/td>\n<td>GB\/T 17626,6\/IEC61000-4-6<\/td>\n<td>3 V (150 kHz-80 MHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Anmerkung 1: F\u00fcr die Leistungsstufe A bleibt die Leistung innerhalb der technischen Spezifikationsgrenzen normal<\/p>\n<p>Anmerkung 2: F\u00fcr die Leistungsstufe B kann die Funktion oder Leistung vor\u00fcbergehend abnehmen oder verloren gehen, kann aber automatisch wiederhergestellt werden, der tats\u00e4chliche Betriebsstatus, die Speicherung und die Daten bleiben unver\u00e4ndert<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Stromversorgungs- und Ladebedingungen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Artikel<\/th>\n<th>Betriebsbedingung<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Stromversorgungsspannung<\/td>\n<td colspan=\"2\">HART-Kommunikationsprotokoll: 16,5 V~36 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Eigensichere Version: HART-Kommunikationsprotokoll: 18,5 V~28 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Modbus-RTU\/RS485: 12 V~36 V DC<\/td>\n<\/tr>\n<tr>\n<td>Belastungswiderstand<\/td>\n<td colspan=\"2\">0 2119 W\u00c4HREND des Betriebs<\/p>\n<p>25 ~ 600 HART f\u00fcr HART Kommunikation<\/td>\n<\/tr>\n<tr>\n<td>\u00dcbertragungsentfernung<\/td>\n<td colspan=\"2\">&lt; 1000m<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Stromverbrauch<\/td>\n<\/tr>\n<tr>\n<td>4 mA~20 mA<\/td>\n<td colspan=\"2\">&lt;= 500 mW@24 V DC, 20,8 mA<\/td>\n<\/tr>\n<tr>\n<td>Modbus-RTU\/RS485<\/td>\n<td>&lt;= 240 mW@24 V DC, 10 mA<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Der hygienische Absolutdrucksender ADDA-P-1GW ist f\u00fcr die Druck- und F\u00fcllstandsmessung in Lebensmittel-, Getr\u00e4nke-, Pharma- und Biotechnikanwendungen konzipiert. Produktdetails beschreiben eine Sanit\u00e4rstruktur aus Edelstahl, ein rotierendes 355\u00b0 -LCD-Modul, monokristalline Piezoretechnologie aus Silizium, 420 mA DC + HART oder Modbus-RTU\/RS485-Ausgang und IP67-Schutz.<\/p>","protected":false},"featured_media":812,"template":"","meta":{"rank_math_title":"Sanitary Absolute Pressure Transmitter | Flush-Face Design","rank_math_description":"Sanitary absolute pressure transmitter has a flush diaphragm and stainless steel body for hygienic pressure and level sensing in process plants.","rank_math_canonical_url":"","rank_math_focus_keyword":"Sanitary Absolute Pressure Transmitter"},"product_brand":[],"product_cat":[41,32],"product_tag":[],"class_list":["post-814","product","type-product","status-publish","has-post-thumbnail","product_cat-pressure-transmitters","product_cat-sanitary-transmitters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product\/814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media\/812"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media?parent=814"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_brand?post=814"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_cat?post=814"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_tag?post=814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}