{"id":440,"date":"2026-07-07T01:54:40","date_gmt":"2026-07-07T01:54:40","guid":{"rendered":"https:\/\/addameter.com\/product\/temperature-transmitter\/"},"modified":"2026-10-21T04:02:23","modified_gmt":"2026-10-21T04:02:23","slug":"temperature-transmitter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/de\/produkt\/temperature-transmitter\/","title":{"rendered":"Temperatursender"},"content":{"rendered":"<style>\n.adda-product-description{font-size:15px;line-height:1.72;color:#4b5563}<br \/>.adda-product-description strong{color:#111827}<br \/>.adda-table-wrap{width:100%;overflow-x:auto;margin:18px 0 26px;border:1px solid #e5e7eb;border-radius:6px;background:#fff}<br \/>.adda-spec-table{width:100%;min-width:720px;border-collapse:collapse;margin:0;font-size:14px;line-height:1.55}<br \/>.adda-spec-table th,.adda-spec-table td{border:1px solid #e5e7eb;padding:11px 14px;vertical-align:top;text-align:left}<br \/>.adda-spec-table th{background:#f6f7f9;color:#111827;font-weight:700}<br \/>.adda-spec-table td:first-child{color:#111827;font-weight:600}<br \/>.adda-spec-table tr:nth-child(even) td{background:#fafafa}<br \/>.adda-spec-table p{margin:0 0 6px}<br \/>.adda-spec-table p:last-child{margin-bottom:0}<br \/>.adda-spec-note{background:#fff8f4!important;color:#374151!important;font-weight:400!important}<br \/>@media (max-width:767px){.adda-product-description{font-size:14px}.adda-spec-table{min-width:680px;font-size:13px}.adda-spec-table th,.adda-spec-table td{padding:9px 11px}}<br \/><\/style>\n<div class=\"adda-product-description\">\n<h3>Temperatursender<\/h3>\n<p><strong>Produktmerkmale<\/strong><\/p>\n<p>The ADDA-T-GY Series thermocouple and RTD temperature transmitter measures, transmits, and displays the temperature of solid surfaces, liquids, and gases. Key features include:<\/p>\n<ul>\n<li>Mit Silikonkautschuk oder Epoxidharz f\u00fcr Vibrations - und Feuchtigkeitsbest\u00e4ndigkeit versiegelt; geeignet f\u00fcr raue Einsatzumgebungen.<\/li>\n<li>Hohe Genauigkeit, geringer Ruhestromverbrauch, stabiler und zuverl\u00e4ssiger Betrieb und lange Lebensdauer.<\/li>\n<li>Two-wire 4mA.dc.~20mA.dc output with strong interference resistance and long transmission distance.<\/li>\n<li>Digital cold-junction compensation and nonlinear correction.<\/li>\n<li>Intrinsically safe and flameproof versions for installation in Zone 0, Zone 1, Zone 2, and other hazardous areas.<\/li>\n<li>The digital display orientation can be adjusted to suit installation requirements. It displays measured temperature, output current, and percentage in real time.<\/li>\n<li>HART communication supports local or remote parameter adjustment and monitoring through a handheld communicator.<\/li>\n<\/ul>\n<p><strong>Anwendungen<\/strong><\/p>\n<p>Temperature measurement in petroleum, chemical, metallurgical, electric power, and other industries.<\/p>\n<p><strong>Messmedium<\/strong><\/p>\n<p>Mit den benetzten Materialien kompatible Medien.<\/p>\n<p><strong>Leistungsspezifikationen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Genauigkeit<\/th>\n<th>\u00b10,11TP3 T, \u00b10,21TP3 T, 0,51TP3 T Obere Bereichsgrenze, Einzelheiten siehe Spezifikationen<\/th>\n<\/tr>\n<tr>\n<td>Reichweite<\/td>\n<td>-230~1820 degrees C, see selection table for details<\/td>\n<\/tr>\n<tr>\n<td>J\u00e4hrliche Stabilit\u00e4t<\/td>\n<td>\u00b10.1% Span\/2 years<\/td>\n<\/tr>\n<tr>\n<td>Spannungseinfluss<\/td>\n<td>Wenn die Versorgungsspannung innerhalb von 10,5 V\/16,5 V~36 V DC variiert, d\u00fcrfen \u00c4nderungen des Nullpunkts und der Spanne \u00b10,001%URL\/V nicht \u00fcberschreiten<\/td>\n<\/tr>\n<tr>\n<td>Ausgangssignal<\/td>\n<td>4 mA~20 mADC+HART<\/p>\n<p>Modbus-RTU\/RS485<\/td>\n<\/tr>\n<tr>\n<td>Schutzgrad<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Reichweite<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Sensortyp<\/th>\n<th>Messbereich Grad C<\/th>\n<th>Minimaler messbarer Bereich Grad C<\/th>\n<th>Messgenauigkeit (je nachdem, welcher Wert gr\u00f6\u00dfer ist) Grad C<\/th>\n<\/tr>\n<tr>\n<td>Pt100<\/td>\n<td>-200~600<\/td>\n<td>50<\/td>\n<td>\u00b10,21TP3 T-Bereich oder \u00b10,2<\/td>\n<\/tr>\n<tr>\n<td>Pt1000<\/td>\n<td>-200~350<\/td>\n<td>50<\/td>\n<td>\u00b10,21TP3 T-Bereich oder \u00b10,2<\/td>\n<\/tr>\n<tr>\n<td>K<\/td>\n<td>-230~1370<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>N<\/td>\n<td>-200~1300<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>-200~1000<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>J<\/td>\n<td>-210~1200<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>T<\/td>\n<td>-200~400<\/td>\n<td>100<\/td>\n<td>\u00b10.1% range or \u00b10.5<\/td>\n<\/tr>\n<tr>\n<td>R<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td>S<\/td>\n<td>-50~1760<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>0~1820<\/td>\n<td>200<\/td>\n<td>\u00b10.1% range or \u00b11<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"4\">Note: cold-junction compensation error must also be added during thermocouple measurement (internal cold-junction error &lt;0.5 degrees C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Umweltbedingungen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<td>Artikel<\/td>\n<td colspan=\"2\">Bedingung<\/td>\n<\/tr>\n<tr>\n<td>Betriebsumgebungstemperaturbereich<\/td>\n<td colspan=\"2\">-40 Grad C ~ 85 Grad C, LCD-Display: -20 Grad C ~ 70 Grad C<\/td>\n<\/tr>\n<tr>\n<td>Speicherumgebungstemperaturbereich<\/td>\n<td colspan=\"2\">-40 Grad C ~ 100 Grad C, LCD-Display: -40 Grad C ~ 85 Grad C<\/td>\n<\/tr>\n<tr>\n<td>Betriebsumgebungsfeuchtigkeitsbereich<\/td>\n<td colspan=\"2\">5%RH~100%RH@40 Grad C<\/td>\n<\/tr>\n<tr>\n<th>Gefahrenbereich<\/th>\n<th>PCEC<\/th>\n<th>Zertifikat Nr: CE19.2398 X Zertifikat Nr: CE19.3332<\/p>\n<p>Ex ia IIC T6 Ga Ex d IIC T6 Gb<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Elektromagnetische Vertr\u00e4glichkeitsumgebung<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Nein.<\/th>\n<th>Testgegenstand<\/th>\n<th>Grundstandard<\/th>\n<th>Testbedingung<\/th>\n<th>Leistungsniveau<\/th>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Strahlungsst\u00f6rung (Geh\u00e4use)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>30 MHz-1000 MHz<\/td>\n<td>B (Anmerkung 2)<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Durchgef\u00fchrte St\u00f6rung (DC Power Port)<\/td>\n<td>GB\/T 9254.1\/CISPR22<\/td>\n<td>0,15 MHz-30 MHz<\/td>\n<td>B (Anmerkung 2)<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Immunit\u00e4t gegen elektrostatische Entladung (ESD)<\/td>\n<td>GB\/T 17626.2\/IEC61000-4-2<\/td>\n<td>4 kV (Kontakt), 8 kV (Luft)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Immunit\u00e4t gegen elektromagnetische HF-Felder<\/td>\n<td>GB\/T 17626.3\/IEC61000-4-3<\/td>\n<td>10 V\/m (80 MHz-1 GHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Immunit\u00e4t des magnetischen Feldes mit hoher Frequenz<\/td>\n<td>GB\/T 17626,8\/IEC61000-4-8<\/td>\n<td>30 A\/m<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Elektrische schnelle vor\u00fcbergehende\/Burst-Immunit\u00e4t<\/td>\n<td>GB\/T 17626.4\/IEC61000-4-4<\/td>\n<td>2 kV (5\/50 ns, 100 kHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Surge-immunit\u00e4t<\/td>\n<td>GB\/T 17626,5\/IEC61000-4-5<\/td>\n<td>4 kV (Line-to-Line)<\/p>\n<p>2 kV (line-to-ground)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Durch HF-Felder induzierte St\u00f6rungsimmunit\u00e4t<\/td>\n<td>GB\/T 17626,6\/IEC61000-4-6<\/td>\n<td>3 V (150 kHz-80 MHz)<\/td>\n<td>A (Anmerkung 1)<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"5\">Anmerkung 1: F\u00fcr die Leistungsstufe A bleibt die Leistung innerhalb der technischen Spezifikationsgrenzen normal<\/p>\n<p>Anmerkung 2: F\u00fcr die Leistungsstufe B kann die Funktion oder Leistung vor\u00fcbergehend abnehmen oder verloren gehen, kann aber automatisch wiederhergestellt werden, der tats\u00e4chliche Betriebsstatus, die Speicherung und die Daten bleiben unver\u00e4ndert<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Stromversorgungs- und Ladebedingungen<\/strong><\/p>\n<div class=\"adda-table-wrap\">\n<table class=\"adda-spec-table\">\n<tbody>\n<tr>\n<th>Artikel<\/th>\n<th>Betriebsbedingung<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Stromversorgungsspannung<\/td>\n<td colspan=\"2\">HART-Kommunikationsprotokoll: 16,5 V~36 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Eigensichere Version: HART-Kommunikationsprotokoll: 18,5 V~28 V DC<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Modbus-RTU\/RS485: 12 V~36 V DC<\/td>\n<\/tr>\n<tr>\n<td>Belastungswiderstand<\/td>\n<td colspan=\"2\">0 2119 W\u00c4HREND des Betriebs<\/p>\n<p>25 ~ 600 HART f\u00fcr HART Kommunikation<\/td>\n<\/tr>\n<tr>\n<td>\u00dcbertragungsentfernung<\/td>\n<td colspan=\"2\">&lt; 1000m<\/td>\n<\/tr>\n<tr>\n<td class=\"adda-spec-note\" colspan=\"3\">Stromverbrauch<\/td>\n<\/tr>\n<tr>\n<td>4 mA~20 mA<\/td>\n<td colspan=\"2\">&lt;= 500 mW@24 V DC, 20,8 mA<\/td>\n<\/tr>\n<tr>\n<td>Modbus-RTU\/RS485<\/td>\n<td colspan=\"2\">&lt;= 240 mW@24 V DC, 10 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Der Temperatursender der ADDA-T-GY-Serie verwendet Thermoelement- oder RTD-Erkennung, um die Temperatur fester Oberfl\u00e4chen, Fl\u00fcssigkeiten und Gase zu messen, zu \u00fcbertragen und anzuzeigen. Er unterst\u00fctzt die digitale Kompensation von Kalt\u00fcberg\u00e4ngen, nichtlineare Korrektur und lokale oder entfernte Parameteranpassung durch HART-Kommunikation.<\/p>","protected":false},"featured_media":438,"template":"","meta":{"rank_math_title":"ADDA Temperature Transmitter | RTD and Thermocouple Inputs","rank_math_description":"Explore the temperature transmitter with two-wire 4 to 20 mA output and HART communication for local or remote setup and process monitoring.","rank_math_canonical_url":"","rank_math_focus_keyword":"Temperature Transmitter"},"product_brand":[],"product_cat":[24,42],"product_tag":[],"class_list":["post-440","product","type-product","status-publish","has-post-thumbnail","product_cat-smart-industrial-transmitters","product_cat-temperature-transmitters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product\/440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media\/438"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media?parent=440"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_brand?post=440"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_cat?post=440"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_tag?post=440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}