{"id":4055,"date":"2026-10-14T01:48:03","date_gmt":"2026-10-14T01:48:03","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-wl-liquid-turbine-flow-meter\/"},"modified":"2026-10-21T04:00:17","modified_gmt":"2026-10-21T04:00:17","slug":"adda-fl-wl-liquid-turbine-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/de\/produkt\/adda-fl-wl-liquid-turbine-flow-meter\/","title":{"rendered":"ADDA-FL-WL-Fl\u00fcssigturbinen-Durchflussmesser"},"content":{"rendered":"<p><a href=\"#overview\">\u00dcbersicht<\/a> | <a href=\"#specifications\">Spezifikationen<\/a> | <a href=\"#liquid-flow-ranges\">Durchflussbereiche<\/a> | <a href=\"#dimensions\">Abmessungen<\/a> | <a href=\"#installation-requirements\">Installation<\/a><\/p>\n<h2 id=\"overview\">\u00dcbersicht<\/h2>\n<p>The ADDA-FL-WL is a velocity-type turbine flow meter for clean, low-viscosity liquids that are not strongly corrosive. Liquid passing through the meter drives a rotor; its speed is converted into an electrical signal proportional to flow. The series is used in food and pharmaceutical processing, fine chemicals, petroleum and other liquid measurement applications.<\/p>\n<p>Select the wetted materials, process connection and electronics to suit the liquid, operating pressure, temperature and required flow range.<\/p>\n<h2 id=\"features\">Merkmale<\/h2>\n<ul>\n<li>Nominal sizes from DN4 to DN300, depending on connection type.<\/li>\n<li>GA versions without local display and GN versions with an integral LCD.<\/li>\n<li>Pulse, 4\u201320 mA, Modbus RTU over RS485 and HART options, depending on electronics.<\/li>\n<li>GN versions display volumetric flow and can calculate mass flow from a configured liquid density.<\/li>\n<li>Threaded, flanged, wafer and sanitary clamp connection options.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">Funktionsprinzip<\/h2>\n<p>The flowing liquid applies torque to the angled turbine blades. Within the calibrated operating range, rotor speed is proportional to average liquid velocity. A magnetic pickup detects the rotating blades and generates pulses; the electronics process these pulses to indicate instantaneous flow and totalized volume.<\/p>\n<p>Q = 3.6 \u00d7 f \/ K, where Q is volumetric flow at operating conditions in m\u00b3\/h, f is pulse frequency in Hz, and K is the meter factor in pulses per litre. Use the meter factor stated in the individual calibration report.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4052\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp\" alt=\"Turbine rotor, electromagnetic conversion, pulse calculation and output diagram\" width=\"1200\" height=\"430\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3.webp 1200w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-300x108.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-1024x367.webp 1024w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-768x275.webp 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-18x6.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image3-600x215.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><figcaption>Turbine flow measurement principle<\/figcaption><\/figure>\n<h2 id=\"specifications\">Technische Spezifikationen<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Parameter<\/th>\n<th scope=\"col\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Modell<\/th>\n<td>ADDA-FL-WL<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Suitable liquids<\/th>\n<td>Clean liquids without solid impurities; kinematic viscosity below 10 mm\u00b2\/s; not strongly corrosive<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Meter body<\/th>\n<td>304 or 316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor materials, DN4\u2013DN125<\/th>\n<td>2Cr13 stainless steel or 2205 duplex stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor materials, DN150\u2013DN300<\/th>\n<td>304 hub with 430 blades, or 316 hub with 2205 duplex stainless steel blades<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process temperature<\/th>\n<td>\u221240 to +120\u00b0C or \u221240 to +150\u00b0C, depending on version; \u221240 to +80\u00b0C option also listed in the ordering guide<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ambient temperature<\/th>\n<td>\u221220 to +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Relative humidity<\/th>\n<td>5\u201395%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Druckbewertung<\/th>\n<td>PN10\u2013PN400 or Class 150\u20132500, depending on nominal size and connection<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accuracy options<\/th>\n<td>Version-dependent; see electronics table below. Class 0.2 is available on request.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced product standard<\/th>\n<td>JB\/T 9246-2016, Turbine Flow Sensors<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced verification regulation<\/th>\n<td>JJG 1037-2008, Turbine Flowmeters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Verbindungsm\u00f6glichkeiten verarbeiten<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Connection<\/th>\n<th scope=\"col\">Available nominal sizes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">External thread<\/th>\n<td>DN4\u2013DN80<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Internal thread<\/th>\n<td>DN4-DN50<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flanschiert<\/th>\n<td>DN4\u2013DN300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Wafer<\/th>\n<td>DN15-DN200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Sanitary clamp<\/th>\n<td>DN4\u2013DN100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"electronics-versions\">Electronics Versions<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Parameter<\/th>\n<th scope=\"col\">GA without local display<\/th>\n<th scope=\"col\">GN with integral LCD<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Function<\/th>\n<td>Remote transmission for flow computers, PLCs and control systems<\/td>\n<td>Local indication and remote signal transmission<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accuracy classes<\/th>\n<td>2.5, 1.5, 1.0 or 0.5<\/td>\n<td>0.5, 0.3 or 0.2; class 0.2 on request<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Repeatability<\/th>\n<td>Better than 0.15%<\/td>\n<td>Better than 0.15%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Stromversorgung<\/th>\n<td>24 V DC nominal; 5\u201332 V DC or 16\u201332 V DC depending on output<\/td>\n<td>24 V DC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabeoptionen<\/th>\n<td>Pulse or 4\u201320 mA<\/td>\n<td>Pulse or two-wire 4\u201320 mA; HART and Modbus RTU over RS485 configurations available<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electrical connections<\/th>\n<td>Circular plug, cable lead or Hirschmann-type connector<\/td>\n<td>M20 \u00d7 1.5 or 1\/2 NPT<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Eindringschutz<\/th>\n<td>IP65 or IP67, depending on version<\/td>\n<td>IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Output, power-supply and protection options must be selected as a compatible configuration. Hazardous-area versions are available on request; confirm the marking and applicable certification for the supplied unit.<\/p>\n<h2 id=\"liquid-flow-ranges\">Liquid Flow Ranges<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Nenngr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Flow range (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>0.04\u20130.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>0.06\u20130.6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.15\u20131.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.5\u20136<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.45\u20139<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.5\u201310<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>0.8\u201315<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>1\u201320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>2\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>5\u201370<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>7\u2013100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>10\u2013200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>13\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>15\u2013300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>40\u2013800<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>100\u20131000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>120\u20131200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Select a size so that the normal operating flow is preferably within 20\u201380% of the selected meter\u2019s maximum flow. Confirm suitability against liquid properties and process conditions.<\/p>\n<h2 id=\"pressure-rating-options\">Pressure Rating Options<\/h2>\n<table>\n<caption>Pressure Rating Options \u2014 Part 1 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">External thread PN<\/th>\n<th scope=\"col\">Internal thread PN<\/th>\n<th scope=\"col\">Flanged PN<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>16\u201363<\/td>\n<td>16\u201363<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>16\u201363<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>16\u201363<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>16\u201340<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Pressure Rating Options \u2014 Part 2 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Flanged Class<\/th>\n<th scope=\"col\">Wafer PN<\/th>\n<th scope=\"col\">Wafer Class<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>150\u20131500<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>150\u2013600<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>150\u2013300<\/td>\n<td>63\u2013400<\/td>\n<td>150\u20132500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>150\u2013300<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>150<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Pressure Rating Options \u2014 Part 3 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Clamp PN<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>10<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>PN and Class are separate rating systems. Available ratings depend on the connection and size. Entries marked \u201c\u2014\u201d are not specified here; confirm on request.<\/p>\n<h2 id=\"selection-options\">Selection Options<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Auswahl<\/th>\n<th scope=\"col\">Code<\/th>\n<th scope=\"col\">Option<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Electronics<\/th>\n<td>GA<\/td>\n<td>Without local display<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electronics<\/th>\n<td>GN<\/td>\n<td>Integral LCD<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F1<\/td>\n<td>Flanschiert<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F2<\/td>\n<td>Wafer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F3<\/td>\n<td>Sanitary clamp<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>L1<\/td>\n<td>External thread<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>L2<\/td>\n<td>Internal thread<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>4<\/td>\n<td>Edelstahl 304<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>6<\/td>\n<td>316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor material<\/th>\n<td>2C<\/td>\n<td>2Cr13 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rotor material<\/th>\n<td>25<\/td>\n<td>2205 duplex stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GA1<\/td>\n<td>24 V DC, no local display, 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GA2<\/td>\n<td>24 V DC, no local display, pulse<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GN1<\/td>\n<td>24 V DC, local display, pulse<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GN2<\/td>\n<td>24 V DC, local display, 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GN3<\/td>\n<td>24 V DC, local display, 4\u201320 mA + HART<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ausgabe<\/th>\n<td>GN4<\/td>\n<td>24 V DC, local display, Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>1<\/td>\n<td>\u221240 to +80\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>2<\/td>\n<td>\u221240 to +120\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature<\/th>\n<td>3<\/td>\n<td>\u221240 to +150\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>N<\/td>\n<td>Non-explosion-protected version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>D<\/td>\n<td>Flameproof version; confirm marking and certification for the selected configuration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>State the required nominal size, pressure rating, accuracy class, electrical connection and transmitter appearance when ordering. The final configuration must be confirmed for the application.<\/p>\n<h2 id=\"dimensions\">Abmessungen<\/h2>\n<p>Dimensions are in millimetres unless otherwise stated. Use the dimensional drawing and table for the selected connection and pressure rating.<\/p>\n<h3>External Thread Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4023\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp\" alt=\"ADDA-FL-WL turbine flow meter side-view dimensional drawing with threaded ends\" width=\"606\" height=\"420\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8.webp 606w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-300x208.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image8-600x416.webp 600w\" sizes=\"(max-width: 606px) 100vw, 606px\" \/><\/a><figcaption>External-thread connection, DN4\u2013DN10, with straight pipe sections<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4024\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp\" alt=\"ADDA-FL-WL threaded turbine flow meter side and end dimensions\" width=\"745\" height=\"641\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9.webp 745w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-300x258.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-14x12.webp 14w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image9-600x516.webp 600w\" sizes=\"(max-width: 745px) 100vw, 745px\" \/><\/a><figcaption>External-thread connection, DN15\u2013DN80<\/figcaption><\/figure>\n<p>DN4\u2013DN10 external-thread versions include straight pipe sections. DN15\u2013DN80 versions do not include straight pipe sections.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Druckbewertung<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">G male thread<\/th>\n<th scope=\"col\">b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN63 or lower<\/td>\n<td>296<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN63 or lower<\/td>\n<td>296<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN63 or lower<\/td>\n<td>413<\/td>\n<td>G1\/2<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G1<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN63 or lower<\/td>\n<td>85<\/td>\n<td>G1<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>PN63 or lower<\/td>\n<td>100<\/td>\n<td>G1-1\/4<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN63 or lower<\/td>\n<td>140<\/td>\n<td>G2<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>PN63 or lower<\/td>\n<td>140<\/td>\n<td>G2<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>PN63 or lower<\/td>\n<td>150<\/td>\n<td>G2-1\/2<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN63 or lower<\/td>\n<td>170<\/td>\n<td>G3<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>PN63 or lower<\/td>\n<td>200<\/td>\n<td>G4<\/td>\n<td>40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Internal Thread Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4025\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp\" alt=\"ADDA-FL-WL flanged turbine flow meter side-view dimensional drawing\" width=\"549\" height=\"705\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10.webp 549w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10-234x300.webp 234w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image10-9x12.webp 9w\" sizes=\"(max-width: 549px) 100vw, 549px\" \/><\/a><figcaption>Internal-thread connection, DN4\u2013DN50<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Druckbewertung<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">G female thread<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G3\/8<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G3\/8<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN63 or lower<\/td>\n<td>75<\/td>\n<td>G1\/2<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN63 or lower<\/td>\n<td>100<\/td>\n<td>G1\/2<\/td>\n<td>44<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G3\/4<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1<\/td>\n<td>49<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1-1\/4<\/td>\n<td>56<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G1-1\/2<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>PN63 or lower<\/td>\n<td>120<\/td>\n<td>G2<\/td>\n<td>72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Flanged Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4026\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp\" alt=\"ADDA-FL-WL turbine flow meter side and end dimensional views\" width=\"750\" height=\"441\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12.webp 750w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-300x176.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image12-600x353.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><figcaption>Small-bore flanged connection with straight pipe sections<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4027\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp\" alt=\"ADDA-FL-WL flange bolt pattern and transmitter dimensional views\" width=\"714\" height=\"489\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13.webp 714w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-300x205.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-18x12.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image13-600x411.webp 600w\" sizes=\"(max-width: 714px) 100vw, 714px\" \/><\/a><figcaption>Flanged connection dimensions<\/figcaption><\/figure>\n<table>\n<caption>PN flange dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Druckbewertung<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN40 or lower<\/td>\n<td>296<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN40 or lower<\/td>\n<td>296<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN40 or lower<\/td>\n<td>413<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN40 or lower<\/td>\n<td>75<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN40 or lower<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>PN40 or lower<\/td>\n<td>100<\/td>\n<td>115<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN40 or lower<\/td>\n<td>140<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>PN40 or lower<\/td>\n<td>140<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>PN40 or lower<\/td>\n<td>150<\/td>\n<td>165<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN16<\/td>\n<td>170<\/td>\n<td>185<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>PN16<\/td>\n<td>200<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>PN16<\/td>\n<td>220<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>PN16<\/td>\n<td>250<\/td>\n<td>250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>PN16<\/td>\n<td>300<\/td>\n<td>285<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>PN16<\/td>\n<td>350<\/td>\n<td>340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>PN16<\/td>\n<td>400<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>PN16<\/td>\n<td>350<\/td>\n<td>460<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>PN flange dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">K (mm)<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">n holes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>65<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>75<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>85<\/td>\n<td>14<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>100<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>110<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>125<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>145<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>160<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>180<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>210<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>240<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>295<\/td>\n<td>22<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>355<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>410<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Class 150 flange dimensions \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Pressure class<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>Class150<\/td>\n<td>296<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>Class150<\/td>\n<td>296<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>Class150<\/td>\n<td>413<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>Class150<\/td>\n<td>75<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>Class150<\/td>\n<td>85<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>Class150<\/td>\n<td>100<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>Class150<\/td>\n<td>140<\/td>\n<td>115<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>Class150<\/td>\n<td>140<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>Class150<\/td>\n<td>150<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>Class150<\/td>\n<td>170<\/td>\n<td>180<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>Class150<\/td>\n<td>200<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>Class150<\/td>\n<td>220<\/td>\n<td>230<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>Class150<\/td>\n<td>250<\/td>\n<td>255<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>Class150<\/td>\n<td>300<\/td>\n<td>280<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>Class150<\/td>\n<td>350<\/td>\n<td>345<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>Class150<\/td>\n<td>400<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>Class150<\/td>\n<td>350<\/td>\n<td>485<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Class 150 flange dimensions \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">K (mm)<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">n holes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>60.3<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>69.9<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>79.4<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>88.9<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>98.4<\/td>\n<td>16<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>120.7<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>139.7<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>152.4<\/td>\n<td>18<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>190.5<\/td>\n<td>18<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>215.9<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>241.3<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>298.5<\/td>\n<td>22<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>362<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>431.8<\/td>\n<td>26<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Wafer Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4028\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp\" alt=\"ADDA-FL-WL flanged turbine flow meter side and front dimensions\" width=\"544\" height=\"476\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14.webp 544w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14-300x263.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image14-14x12.webp 14w\" sizes=\"(max-width: 544px) 100vw, 544px\" \/><\/a><figcaption>Wafer connection dimensions<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Druckbewertung<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN400 or lower<\/td>\n<td>65<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN400 or lower<\/td>\n<td>60<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>PN400 or lower<\/td>\n<td>60<\/td>\n<td>58<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>72<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>PN400 or lower<\/td>\n<td>70<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN400 or lower<\/td>\n<td>80<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>PN400 or lower<\/td>\n<td>90<\/td>\n<td>112<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>PN400 or lower<\/td>\n<td>100<\/td>\n<td>137<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>PN400 or lower<\/td>\n<td>120<\/td>\n<td>165<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>PN400 or lower<\/td>\n<td>150<\/td>\n<td>190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>PN400 or lower<\/td>\n<td>150<\/td>\n<td>242<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The catalogue gives the same wafer body dimensions across the available pressure ratings. When supplied with mating weld-neck flanges, total length equals the standard body length plus twice the mating-flange thickness.<\/p>\n<h3>Sanitary Clamp Connection<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4029\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp\" alt=\"ADDA-FL-WL compact turbine flow meter body and transmitter dimensions\" width=\"391\" height=\"469\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15.webp 391w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15-250x300.webp 250w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image15-10x12.webp 10w\" sizes=\"(max-width: 391px) 100vw, 391px\" \/><\/a><figcaption>Sanitary clamp connection dimensions<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4030\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp\" alt=\"ADDA-FL-WL turbine flow meter transmitter and flange front view\" width=\"147\" height=\"306\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16.webp 147w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16-144x300.webp 144w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wl-image16-6x12.webp 6w\" sizes=\"(max-width: 147px) 100vw, 147px\" \/><\/a><figcaption>Sanitary clamp connection end view<\/figcaption><\/figure>\n<table>\n<caption>Sanitary Clamp Connection \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">Druckbewertung<\/th>\n<th scope=\"col\">L (mm)<\/th>\n<th scope=\"col\">D (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>PN10<\/td>\n<td>50<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>PN10<\/td>\n<td>100<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>PN10<\/td>\n<td>120<\/td>\n<td>50.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>PN10<\/td>\n<td>140<\/td>\n<td>64<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>PN10<\/td>\n<td>150<\/td>\n<td>77.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>PN10<\/td>\n<td>170<\/td>\n<td>91<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>PN10<\/td>\n<td>220<\/td>\n<td>130<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Sanitary Clamp Connection \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Gr\u00f6\u00dfe<\/th>\n<th scope=\"col\">d (mm)<\/th>\n<th scope=\"col\">C (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN4<\/th>\n<td>4<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN6<\/th>\n<td>6<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>10<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>15<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>20<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>25<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>32<\/td>\n<td>43.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>40<\/td>\n<td>56.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>50<\/td>\n<td>70.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>65<\/td>\n<td>83.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>80<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>100<\/td>\n<td>122<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"installation-requirements\">Installation Requirements<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Requirement<\/th>\n<th scope=\"col\">Guidance<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Straight pipe after reducers, expanders or elbows<\/th>\n<td>Provide at least 15D upstream and 5D downstream. D is the nominal internal diameter of the flow meter.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pipe alignment<\/th>\n<td>Align the meter and pipeline concentrically before installation.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cleanliness<\/th>\n<td>Flush new pipework before fitting the meter to remove welding debris and other foreign material.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process connections<\/th>\n<td>Use the mating fittings, gaskets, fasteners and sealing method appropriate to the selected thread, flange, wafer or clamp connection.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Fl\u00fcssigkeitsturbinen-Durchflussmesser f\u00fcr saubere, niedrigviskose Fl\u00fcssigkeiten DN4-OwnDN300-Optionen sind mit Gewinde, Flansch, Wafer - oder Sanit\u00e4rklemme-Anschl\u00fcssen erh\u00e4ltlich W\u00e4hlen Sie GA-Elektronik ohne lokales Display oder GN-Elektronik mit integriertem LCD, mit Ausgabem\u00f6glichkeiten passend zum Steuerungssystem.<\/p>","protected":false},"featured_media":4015,"template":"","meta":{"rank_math_title":"ADDA-FL-WL Liquid Turbine Flow Meter | Clean Liquid Flow","rank_math_description":"The ADDA-FL-WL liquid turbine flow meter measures clean, low-viscosity liquids and offers selectable connections, displays and electrical outputs.","rank_math_canonical_url":"","rank_math_focus_keyword":"Liquid Turbine Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4055","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product\/4055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media\/4015"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/media?parent=4055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_brand?post=4055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_cat?post=4055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/de\/wp-json\/wp\/v2\/product_tag?post=4055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}