{"id":4056,"date":"2026-10-14T01:48:03","date_gmt":"2026-10-14T01:48:03","guid":{"rendered":"https:\/\/www.addameter.com\/product\/adda-fl-wj-vortex-flow-meter\/"},"modified":"2026-10-21T04:00:17","modified_gmt":"2026-10-21T04:00:17","slug":"adda-fl-wj-vortex-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/ar\/product\/adda-fl-wj-vortex-flow-meter\/","title":{"rendered":"\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u062f\u0641\u0642 \u0627\u0644\u062f\u0648\u0627\u0645\u064a ADDA-FL-WJ"},"content":{"rendered":"<p><a href=\"#overview\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629<\/a> | <a href=\"#specifications\">\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/a> | <a href=\"#liquid-flow-sizing\">\u0646\u0637\u0627\u0642\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0642<\/a> | <a href=\"#dimensions\">\u0623\u0628\u0639\u0627\u062f<\/a> | <a href=\"#installation-requirements\">\u062a\u062b\u0628\u064a\u062a<\/a><\/p>\n<h2 id=\"overview\">\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>The ADDA-FL-WJ is an inline vortex flow meter based on the K\u00e1rm\u00e1n vortex shedding principle. It measures the flow of compatible single-phase liquids, dry gases and steam. Depending on the selected compensation configuration, the transmitter can indicate operating volumetric flow, normalized volumetric flow or calculated mass flow.<\/p>\n<p>Typical applications include petroleum processing, chemical production, power generation and industrial heating. Select the meter size, materials, temperature range and compensation method to match the medium and operating conditions.<\/p>\n<h2 id=\"features\">\u0633\u0645\u0627\u062a<\/h2>\n<ul>\n<li>No moving parts in the measuring body.<\/li>\n<li>Flanged and wafer connections from DN15 to DN300.<\/li>\n<li>304 or 316 stainless steel body and probe options.<\/li>\n<li>Temperature versions up to +250\u00b0C or +350\u00b0C.<\/li>\n<li>Frequency, scaled pulse, two-wire 4\u201320 mA, HART and Modbus RTU over RS485 options.<\/li>\n<li>Configurations without compensation, with temperature compensation, or with temperature and pressure compensation.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">\u0645\u0628\u062f\u0623 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h2>\n<p>A fixed bluff body in the flow path generates alternating vortices downstream. Within the specified Reynolds-number range, the vortex shedding frequency is proportional to flow velocity. A piezoelectric or capacitive pickup detects the resulting pressure fluctuations, and the transmitter converts their frequency into flow.<\/p>\n<p>f = St \u00d7 v \/ d, where f is vortex shedding frequency, St is the Strouhal number, v is flow velocity and d is the bluff-body width. Volumetric flow is derived from the calibrated meter factor K; frequency and volume units must be consistent when applying Q = f \/ K.<\/p>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image25.webp\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-4031\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image25.webp\" alt=\"Vortex shedding diagram showing alternating vortices behind a bluff body\" width=\"448\" height=\"201\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image25.webp 448w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image25-300x135.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image25-18x8.webp 18w\" sizes=\"(max-width: 448px) 100vw, 448px\" \/><\/a><figcaption>K\u00e1rm\u00e1n vortex shedding principle<\/figcaption><\/figure>\n<h2 id=\"specifications\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0645\u0639\u0644\u0645\u0629<\/th>\n<th scope=\"col\">\u062a\u062e\u0635\u064a\u0635<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Model<\/th>\n<td>ADDA-FL-WJ<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Suitable media<\/th>\n<td>Compatible single-phase liquids, dry gases and steam<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0627\u0644\u062d\u062c\u0645 \u0627\u0644\u0627\u0633\u0645\u064a<\/th>\n<td>DN15\u2013DN300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process connections<\/th>\n<td>Flanged or wafer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>304 or 316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Probe material<\/th>\n<td>304 or 316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Process temperature<\/th>\n<td>Standard\/medium-temperature version: \u221240 to +250\u00b0C; high-temperature version: \u221240 to +350\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal pressure<\/th>\n<td>PN10\u2013PN63, depending on configuration<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accuracy classes<\/th>\n<td>1.0 or 1.5 for gas and liquid service<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Repeatability<\/th>\n<td>Better than one third of the absolute maximum permissible error for the selected accuracy class<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ambient temperature<\/th>\n<td>\u221210 to +55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Relative humidity<\/th>\n<td>5\u201390%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Atmospheric pressure<\/th>\n<td>86\u2013106 kPa<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0645\u0635\u062f\u0631 \u0637\u0627\u0642\u0629<\/th>\n<td>24 V DC nominal (18\u201329 V DC); 3.6 V lithium battery; or 24 V DC with 3.6 V battery, depending on configuration<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>Frequency; scaled pulse; two-wire 4\u201320 mA; Modbus RTU over RS485; HART<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062f\u062e\u0648\u0644<\/th>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced product standard<\/th>\n<td>JB\/T 9249-2015, Vortex Flow Sensors<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Referenced verification regulation<\/th>\n<td>JJG 1029-2007, Vortex Flowmeters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Required compensation, output and power options must be selected together. Operating limits depend on medium density, Reynolds number, meter size and process conditions. The catalogue specifies a minimum Reynolds number of 5,000; confirm the selected operating range before ordering.<\/p>\n<h2 id=\"liquid-flow-sizing\">Liquid Flow Sizing<\/h2>\n<p>The tables show the lower measurable flow for different liquid densities. All flow values are in m\u00b3\/h. The reference-flow column is reproduced for sizing comparison; it is not a normalized gas-volume unit.<\/p>\n<table>\n<caption>Liquid minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">500 kg\/m\u00b3<\/th>\n<th scope=\"col\">600 kg\/m\u00b3<\/th>\n<th scope=\"col\">700 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.57<\/td>\n<td>0.52<\/td>\n<td>0.48<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.85<\/td>\n<td>0.77<\/td>\n<td>0.72<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>1.27<\/td>\n<td>1.16<\/td>\n<td>1.08<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>2.12<\/td>\n<td>1.94<\/td>\n<td>1.79<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>3.25<\/td>\n<td>2.97<\/td>\n<td>2.75<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>4.95<\/td>\n<td>4.52<\/td>\n<td>4.18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>8.49<\/td>\n<td>7.75<\/td>\n<td>7.17<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>13<\/td>\n<td>12<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>20<\/td>\n<td>18<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>31<\/td>\n<td>28<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>45<\/td>\n<td>41<\/td>\n<td>38<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>81<\/td>\n<td>74<\/td>\n<td>68<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>126<\/td>\n<td>115<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>180<\/td>\n<td>164<\/td>\n<td>152<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Liquid minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">800 kg\/m\u00b3<\/th>\n<th scope=\"col\">900 kg\/m\u00b3<\/th>\n<th scope=\"col\">Reference flow<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.45<\/td>\n<td>0.42<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.67<\/td>\n<td>0.63<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>1.01<\/td>\n<td>0.95<\/td>\n<td>9<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>1.68<\/td>\n<td>1.58<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>2.57<\/td>\n<td>2.42<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>3.91<\/td>\n<td>3.69<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>6.71<\/td>\n<td>6.32<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>10<\/td>\n<td>9.49<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>16<\/td>\n<td>15<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>25<\/td>\n<td>23<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>36<\/td>\n<td>34<\/td>\n<td>320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>64<\/td>\n<td>60<\/td>\n<td>570<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>100<\/td>\n<td>94<\/td>\n<td>890<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>142<\/td>\n<td>134<\/td>\n<td>1270<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Liquid minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 1 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">1000 kg\/m\u00b3<\/th>\n<th scope=\"col\">1200 kg\/m\u00b3<\/th>\n<th scope=\"col\">1400 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.4<\/td>\n<td>0.37<\/td>\n<td>0.34<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.6<\/td>\n<td>0.55<\/td>\n<td>0.51<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.9<\/td>\n<td>0.82<\/td>\n<td>0.76<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>1.5<\/td>\n<td>1.37<\/td>\n<td>1.27<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>2.3<\/td>\n<td>2.10<\/td>\n<td>1.94<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>3.5<\/td>\n<td>3.20<\/td>\n<td>2.96<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>6<\/td>\n<td>5.48<\/td>\n<td>5.07<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>9<\/td>\n<td>8.22<\/td>\n<td>7.61<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>14<\/td>\n<td>13<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>22<\/td>\n<td>20<\/td>\n<td>19<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>32<\/td>\n<td>29<\/td>\n<td>27<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>57<\/td>\n<td>52<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>89<\/td>\n<td>81<\/td>\n<td>75<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>127<\/td>\n<td>116<\/td>\n<td>107<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Liquid minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 2 of 2<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">1600 kg\/m\u00b3<\/th>\n<th scope=\"col\">1800 kg\/m\u00b3<\/th>\n<th scope=\"col\">Reference flow<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.32<\/td>\n<td>0.30<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.47<\/td>\n<td>0.45<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.71<\/td>\n<td>0.67<\/td>\n<td>9<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>1.19<\/td>\n<td>1.12<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>1.82<\/td>\n<td>1.71<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>2.77<\/td>\n<td>2.61<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>4.74<\/td>\n<td>4.47<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>7.12<\/td>\n<td>6.71<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>\u2014<\/td>\n<td>10<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>17<\/td>\n<td>16<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>25<\/td>\n<td>24<\/td>\n<td>320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>45<\/td>\n<td>42<\/td>\n<td>570<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>70<\/td>\n<td>66<\/td>\n<td>890<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>100<\/td>\n<td>95<\/td>\n<td>1270<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u201c\u2014\u201d means the value must be confirmed on request.<\/p>\n<h2 id=\"gas-flow-sizing\">Gas Flow Sizing<\/h2>\n<p>The gas lower limit depends strongly on density at the measurement conditions. Use the actual gas composition, pressure and temperature when selecting a size and compensation configuration.<\/p>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 1 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">0.5 kg\/m\u00b3<\/th>\n<th scope=\"col\">0.8 kg\/m\u00b3<\/th>\n<th scope=\"col\">1.2 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>9<\/td>\n<td>7<\/td>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>9<\/td>\n<td>7<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>14<\/td>\n<td>11<\/td>\n<td>9<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>23<\/td>\n<td>18<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>34<\/td>\n<td>27<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>54<\/td>\n<td>43<\/td>\n<td>35<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>93<\/td>\n<td>74<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>140<\/td>\n<td>110<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>217<\/td>\n<td>172<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>342<\/td>\n<td>270<\/td>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>466<\/td>\n<td>368<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>854<\/td>\n<td>675<\/td>\n<td>550<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>1397<\/td>\n<td>1105<\/td>\n<td>900<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>2018<\/td>\n<td>1595<\/td>\n<td>1300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 2 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">2.4 kg\/m\u00b3<\/th>\n<th scope=\"col\">3.6 kg\/m\u00b3<\/th>\n<th scope=\"col\">4.8 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>3.5<\/td>\n<td>2.9<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>3.9<\/td>\n<td>3.2<\/td>\n<td>2.8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>6.4<\/td>\n<td>5.2<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>11<\/td>\n<td>8.7<\/td>\n<td>7.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>16<\/td>\n<td>13<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>25<\/td>\n<td>20<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>43<\/td>\n<td>35<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>64<\/td>\n<td>52<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>99<\/td>\n<td>81<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>156<\/td>\n<td>127<\/td>\n<td>110<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>213<\/td>\n<td>174<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>390<\/td>\n<td>318<\/td>\n<td>276<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>638<\/td>\n<td>521<\/td>\n<td>451<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>921<\/td>\n<td>752<\/td>\n<td>651<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 3 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Reference flow<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>30<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>67<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>350<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>600<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>900<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>1400<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>2200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>3000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>5500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>9000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>13000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 1 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">6.0 kg\/m\u00b3<\/th>\n<th scope=\"col\">7.2 kg\/m\u00b3<\/th>\n<th scope=\"col\">8.4 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>2.2<\/td>\n<td>2.0<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>2.5<\/td>\n<td>2.3<\/td>\n<td>2.1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>4.0<\/td>\n<td>3.7<\/td>\n<td>3.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>6.7<\/td>\n<td>6.1<\/td>\n<td>5.7<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>9.9<\/td>\n<td>9.0<\/td>\n<td>8.3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>16<\/td>\n<td>14<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>27<\/td>\n<td>25<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>40<\/td>\n<td>37<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>63<\/td>\n<td>57<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>99<\/td>\n<td>90<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>134<\/td>\n<td>123<\/td>\n<td>114<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>246<\/td>\n<td>225<\/td>\n<td>208<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>403<\/td>\n<td>368<\/td>\n<td>341<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>583<\/td>\n<td>532<\/td>\n<td>492<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 2 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">9.6 kg\/m\u00b3<\/th>\n<th scope=\"col\">12.0 kg\/m\u00b3<\/th>\n<th scope=\"col\">20.0 kg\/m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>1.8<\/td>\n<td>1.6<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>1.9<\/td>\n<td>1.7<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>3.2<\/td>\n<td>2.9<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>5.3<\/td>\n<td>4.8<\/td>\n<td>3.7<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>7.8<\/td>\n<td>7.0<\/td>\n<td>5.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>12<\/td>\n<td>11.1<\/td>\n<td>8.6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>21<\/td>\n<td>19<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>32<\/td>\n<td>29<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>50<\/td>\n<td>44<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>78<\/td>\n<td>72<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>106<\/td>\n<td>95<\/td>\n<td>74<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>195<\/td>\n<td>174<\/td>\n<td>135<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>319<\/td>\n<td>285<\/td>\n<td>221<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>461<\/td>\n<td>412<\/td>\n<td>319<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Gas minimum measurable flow at the stated density (m\u00b3\/h) \u2014 Part 3 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Reference flow<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>30<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>67<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>90<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN32<\/th>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>220<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>350<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>600<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>900<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>1400<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN125<\/th>\n<td>2200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>3000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>5500<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN250<\/th>\n<td>9000<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN300<\/th>\n<td>13000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"selection-options\">Selection Options<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0627\u062e\u062a\u064a\u0627\u0631<\/th>\n<th scope=\"col\">\u0634\u0641\u0631\u0629<\/th>\n<th scope=\"col\">\u062e\u064a\u0627\u0631<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F1<\/td>\n<td>Flanged<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Connection<\/th>\n<td>F2<\/td>\n<td>Wafer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Compensation<\/th>\n<td>N0<\/td>\n<td>Without temperature or pressure compensation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Compensation<\/th>\n<td>WD<\/td>\n<td>Temperature compensation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Compensation<\/th>\n<td>WY<\/td>\n<td>Temperature and pressure compensation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature version<\/th>\n<td>C<\/td>\n<td>\u221240 to +250\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature version<\/th>\n<td>G<\/td>\n<td>\u221240 to +350\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Probe material<\/th>\n<td>4<\/td>\n<td>304 \u0633\u062a\u0627\u0646\u0644\u0633 \u0633\u062a\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Probe material<\/th>\n<td>6<\/td>\n<td>316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>4<\/td>\n<td>304 \u0633\u062a\u0627\u0646\u0644\u0633 \u0633\u062a\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Body material<\/th>\n<td>6<\/td>\n<td>316 stainless steel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>P<\/td>\n<td>Frequency<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>M<\/td>\n<td>Scaled pulse<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>F<\/td>\n<td>\u0633\u0644\u0643\u064a\u0646 4 \u00b7 20 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>H<\/td>\n<td>Two-wire 4\u201320 mA + HART<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>R<\/td>\n<td>Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/th>\n<td>M<\/td>\n<td>M20 \u00d7 1.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/th>\n<td>N<\/td>\n<td>1\/2 NPT<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>N<\/td>\n<td>Non-explosion-protected version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hazardous-area requirement<\/th>\n<td>D<\/td>\n<td>Flameproof version; confirm marking and applicable certification for the supplied configuration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Specify the nominal size, pressure rating, process medium, operating flow, pressure and temperature, required accuracy and power supply. Confirm compatible options and the final configuration before ordering.<\/p>\n<h2 id=\"dimensions\">\u0623\u0628\u0639\u0627\u062f<\/h2>\n<p>Dimensions are in millimetres unless otherwise stated. Confirm the final drawing and pressure rating for the ordered meter.<\/p>\n<h3>Flanged Version<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image26.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4032\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image26.webp\" alt=\"Insertion vortex flow meter probe and pipe mounting dimensions\" width=\"151\" height=\"255\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image26.webp 151w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image26-7x12.webp 7w\" sizes=\"(max-width: 151px) 100vw, 151px\" \/><\/a><figcaption>Flanged version, side view<\/figcaption><\/figure>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image27.webp\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-4033\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image27.webp\" alt=\"Remote vortex flow meter with cable-linked transmitter and flange dimensions\" width=\"225\" height=\"365\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image27.webp 225w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image27-185x300.webp 185w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image27-7x12.webp 7w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/a><figcaption>Flanged version, end view<\/figcaption><\/figure>\n<table>\n<caption>PN10 flanged dimensions \u2014 Part 1 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">Rating<\/th>\n<th scope=\"col\">Standard L<\/th>\n<th scope=\"col\">Available L range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">32<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>PN10<\/td>\n<td>200<\/td>\n<td>200\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>PN10<\/td>\n<td>220<\/td>\n<td>220\u2013250<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">125<\/th>\n<td>PN10<\/td>\n<td>220<\/td>\n<td>220\u2013280<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>PN10<\/td>\n<td>220<\/td>\n<td>220\u2013280<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>PN10<\/td>\n<td>270<\/td>\n<td>270\u2013300<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">250<\/th>\n<td>PN10<\/td>\n<td>310<\/td>\n<td>310\u2013350<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">300<\/th>\n<td>PN10<\/td>\n<td>350<\/td>\n<td>350\u2013350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>PN10 flanged dimensions \u2014 Part 2 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">D<\/th>\n<th scope=\"col\">K<\/th>\n<th scope=\"col\">n\u2013d holes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>95<\/td>\n<td>65<\/td>\n<td>4-14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>105<\/td>\n<td>75<\/td>\n<td>4-14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>115<\/td>\n<td>85<\/td>\n<td>4-14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">32<\/th>\n<td>140<\/td>\n<td>100<\/td>\n<td>4-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>150<\/td>\n<td>110<\/td>\n<td>4-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>165<\/td>\n<td>125<\/td>\n<td>4-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>185<\/td>\n<td>145<\/td>\n<td>8-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>200<\/td>\n<td>160<\/td>\n<td>8-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>220<\/td>\n<td>180<\/td>\n<td>8-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">125<\/th>\n<td>250<\/td>\n<td>210<\/td>\n<td>8-18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>285<\/td>\n<td>240<\/td>\n<td>8-22<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>340<\/td>\n<td>295<\/td>\n<td>12-22<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">250<\/th>\n<td>405<\/td>\n<td>355<\/td>\n<td>12-26<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">300<\/th>\n<td>460<\/td>\n<td>410<\/td>\n<td>12-26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>PN10 flanged dimensions \u2014 Part 3 of 3<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">Bolt size<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>M12\u00d760<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>M12\u00d760<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>M12\u00d760<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">32<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">125<\/th>\n<td>M16\u00d770<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>M20\u00d7100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>M20\u00d7100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">250<\/th>\n<td>M24\u00d7100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">300<\/th>\n<td>M24\u00d7100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The listed flange dimensions are for PN10. Other pressure ratings require a confirmed dimensional drawing. K is the bolt-circle diameter; n\u2013d states the number and diameter of bolt holes.<\/p>\n<h3>Wafer Version<\/h3>\n<figure><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image28.webp\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4034\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image28.webp\" alt=\"Remote vortex flow meter side and end dimensional views\" width=\"255\" height=\"302\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image28.webp 255w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image28-253x300.webp 253w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-wj-image28-10x12.webp 10w\" sizes=\"(max-width: 255px) 100vw, 255px\" \/><\/a><figcaption>Wafer version dimensions<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">Length L<\/th>\n<th scope=\"col\">Outside diameter D<\/th>\n<th scope=\"col\">Connecting pipe OD \u00d7 wall thickness<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>85<\/td>\n<td>87<\/td>\n<td>\u00d818 \u00d7 2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>85<\/td>\n<td>87<\/td>\n<td>\u00d825 \u00d7 3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>85<\/td>\n<td>87<\/td>\n<td>\u00d832 \u00d7 3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">32<\/th>\n<td>85<\/td>\n<td>87<\/td>\n<td>\u00d838 \u00d7 3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>85<\/td>\n<td>100<\/td>\n<td>\u00d845 \u00d7 3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>85<\/td>\n<td>100<\/td>\n<td>\u00d857 \u00d7 3.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>90<\/td>\n<td>120<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>95<\/td>\n<td>136<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>110<\/td>\n<td>149<\/td>\n<td>\u00d8108 \u00d7 4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">125<\/th>\n<td>110<\/td>\n<td>175<\/td>\n<td>\u00d8133 \u00d7 4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>130<\/td>\n<td>203<\/td>\n<td>\u00d8159 \u00d7 4.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>150<\/td>\n<td>259<\/td>\n<td>\u00d8219 \u00d7 6<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">250<\/th>\n<td>180<\/td>\n<td>312<\/td>\n<td>\u00d8273 \u00d7 6.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">300<\/th>\n<td>200<\/td>\n<td>363<\/td>\n<td>\u00d8325 \u00d7 8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u201c\u2014\u201d means the connecting-pipe specification must be confirmed on request.<\/p>\n<h2 id=\"installation-requirements\">Installation Requirements<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Layout or component<\/th>\n<th scope=\"col\">Requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Reducer, expander or elbow upstream<\/th>\n<td>Provide at least 15D of straight pipe upstream and 5D downstream. D is the nominal internal diameter of the meter.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Control valve downstream<\/th>\n<td>Install control valves downstream where possible, retaining at least 5D between the meter and valve. Upstream straight length depends on preceding fittings.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Control valve upstream<\/th>\n<td>If unavoidable, provide at least 25D upstream and 5D downstream.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Piston or plunger pump<\/th>\n<td>Use a suitable upstream accumulator or pulsation damper to reduce liquid pulsations.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pulsating gas or liquid flow<\/th>\n<td>Pulsation from reciprocating pumps, blowers or compressors can disturb measurement. Select an upstream damping arrangement and verify the layout.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Tee branch with intermittent flow<\/th>\n<td>A closed downstream valve can leave the meter exposed to pressure pulsations from the live branch. An appropriately located upstream isolation valve may be needed to isolate the inactive meter branch.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pressure tapping<\/th>\n<td>Locate the pressure measurement point 3\u20135D downstream of the meter.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature tapping<\/th>\n<td>Locate the temperature measurement point 6\u20138D downstream of the meter.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Vibration<\/th>\n<td>Choose a low-vibration location; support the pipeline where necessary.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pipe bore<\/th>\n<td>The catalogue specifies a connecting-pipe internal diameter 1\u20135 mm larger than the meter bore. Confirm the selected mating pipe dimensions.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Assembly<\/th>\n<td>Align the meter and pipe concentrically. Flush pipework to remove welding debris and other foreign material before installing the meter.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Gas and Steam Service<\/h3>\n<p>Prevent condensate from collecting in the measuring section. Vertical mounting or a suitable high-point arrangement in horizontal piping can help avoid liquid accumulation. Do not locate the meter at the bottom of a U-shaped section where condensate can collect.<\/p>\n<h3>Liquid Service<\/h3>\n<p>Keep the measuring tube completely full. Upward flow is preferred in vertical pipework. Where downward flow is used, position the meter below the downstream pipe elevation so the measuring section remains flooded. Avoid high points where gas can collect, and place the meter upstream of a control valve where a pressure drop could create bubbles.<\/p>\n<p>Entrained gas, stratified flow and other mixed-phase conditions can impair accuracy or prevent reliable measurement. Confirm single-phase service and a suitable installation layout before commissioning.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0645\u0642\u064a\u0627\u0633 \u062a\u062f\u0641\u0642 \u062f\u0648\u0627\u0645\u064a \u0645\u0636\u0645\u0646 \u0644\u0644\u0633\u0648\u0627\u0626\u0644 \u0623\u062d\u0627\u062f\u064a\u0629 \u0627\u0644\u0637\u0648\u0631 \u0648\u0627\u0644\u063a\u0627\u0632\u0627\u062a \u0627\u0644\u062c\u0627\u0641\u0629 \u0648\u0627\u0644\u0628\u062e\u0627\u0631 \u0627\u0644\u0645\u062a\u0648\u0627\u0641\u0642\u0629. \u062a\u062a\u0648\u0641\u0631 \u0625\u0635\u062f\u0627\u0631\u0627\u062a \u0630\u0627\u062a \u062d\u0648\u0627\u0641 \u0648\u0631\u0642\u0627\u0642\u0629 DN15 \u0648DN300\u060c \u0645\u0639 \u062e\u064a\u0627\u0631\u0627\u062a \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u062d\u062a\u0649 +350\u00b0 \u0645\u0626\u0648\u064a\u0629 \u0648\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0623\u0648 \u062a\u0639\u0648\u064a\u0636 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0648\u0627\u0644\u0636\u063a\u0637.<\/p>","protected":false},"featured_media":4016,"template":"","meta":{"rank_math_title":"ADDA-FL-WJ Vortex Flow Meter | Liquid, Gas and Steam","rank_math_description":"Review the ADDA-FL-WJ vortex flow meter for compatible liquids, dry gases and steam, with selectable compensation, connections and signal outputs.","rank_math_canonical_url":"","rank_math_focus_keyword":"ADDA-FL-WJ Vortex Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4056","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product\/4056","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media\/4016"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media?parent=4056"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_brand?post=4056"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_cat?post=4056"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_tag?post=4056"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}