{"id":4007,"date":"2026-10-12T09:34:27","date_gmt":"2026-10-12T09:34:27","guid":{"rendered":"https:\/\/www.addameter.com\/?post_type=product&#038;p=4007"},"modified":"2026-10-21T04:00:17","modified_gmt":"2026-10-21T04:00:17","slug":"adda-fl-ty-oval-gear-flow-meter","status":"publish","type":"product","link":"https:\/\/www.addameter.com\/ar\/product\/adda-fl-ty-oval-gear-flow-meter\/","title":{"rendered":"ADDA-FL-TY \u0645\u0642\u064a\u0627\u0633 \u062a\u062f\u0641\u0642 \u0627\u0644\u062a\u0631\u0648\u0633 \u0627\u0644\u0628\u064a\u0636\u0627\u0648\u064a"},"content":{"rendered":"<h2>\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0646\u062a\u062c<\/h2>\n<p>The ADDA-FL-TY Oval Gear Flow Meter is a positive displacement meter for measuring liquids in a completely filled pipe. A pair of intermeshing oval gears divides the liquid into fixed volumes. The number of gear rotations is used to determine the volume passing through the meter.<\/p>\n<p>It is suitable for oil and fuel metering, as well as clean liquids such as lubricating oil, resins, adhesives and syrups. The meter configuration, wetted materials and seals must be selected for the liquid, viscosity, pressure and temperature of the application.<\/p>\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>Positive displacement measurement for a wide range of liquid viscosities.<\/li>\n<li>0.5% accuracy, with a 0.2% option.<\/li>\n<li>No upstream or downstream straight pipe run required.<\/li>\n<li>LCD indication with pulse, 4\u201320 mA and RS485 output options.<\/li>\n<li>Standard, high-temperature, high-viscosity and jacketed configurations available.<\/li>\n<li>Simple, established mechanical construction with good repeatability.<\/li>\n<li>Typical turndown ratio of 10:1; the applicable range depends on viscosity and configuration.<\/li>\n<li>Relatively low pressure loss; actual pressure drop depends on the fluid and operating flow.<\/li>\n<\/ul>\n<h2 id=\"operating-principle\">\u0645\u0628\u062f\u0623 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h2>\n<p>The pressure difference between the inlet and outlet (\u0394P = P\u2081 \u2212 P\u2082) drives a pair of intermeshing oval gears in the measuring chamber. The gears, housing and cover form crescent-shaped measuring cavities. As the gears rotate, they carry fixed volumes of liquid from the inlet to the outlet.<\/p>\n<p>The two gears alternately act as the driving and driven gear. Each quarter-turn displaces one cavity volume; one full revolution displaces four cavity volumes. Gear rotation is transmitted to the counting mechanism through a magnetic coupling or sealed coupling.<\/p>\n<p><strong>Totalized volume: V = 4 \u00d7 u\u2080 \u00d7 n<\/strong>, where u\u2080 is the volume of one crescent-shaped cavity and n is the total number of gear revolutions.<\/p>\n<p><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136.webp\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136.webp\" alt=\"Oval gear flow meter gear positions through a measurement cycle\" width=\"800\" height=\"249\" class=\"aligncenter size-full wp-image-4051\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136.webp 1400w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136-300x93.webp 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136-1024x319.webp 1024w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136-768x239.webp 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136-18x6.webp 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-image136-600x187.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<p><em>Four stages of oval gear rotation. Click the diagram to view the full-size image.<\/em><\/p>\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0645\u0639\u0644\u0645\u0629<\/th>\n<th scope=\"col\">\u062a\u062e\u0635\u064a\u0635<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Model<\/th>\n<td>ADDA-FL-TY<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Measuring principle<\/th>\n<td>Positive displacement with oval gears<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal diameter<\/th>\n<td>DN10\u2013DN200<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062f\u0642\u0629<\/th>\n<td>\u00b10.5% F.S.; \u00b10.2% F.S. optional<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0636\u063a\u0637<\/th>\n<td>1.0\u20136.3 MPa, depending on configuration<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Medium temperature<\/th>\n<td>Standard LCD version: \u221220 to +60\u00b0C; high-temperature LCD version: \u221220 to +150\u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0645\u0627\u062f\u0629<\/th>\n<td>304 or 316L stainless steel; seal materials selected to suit the medium<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0645\u0635\u062f\u0631 \u0637\u0627\u0642\u0629<\/th>\n<td>24 V DC or 3.6 V lithium battery, depending on configuration<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0625\u062e\u0631\u0627\u062c<\/th>\n<td>Pulse, 4\u201320 mA, Modbus RTU over RS485<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u064a\u0639\u0631\u0636<\/th>\n<td>\u0634\u0627\u0634\u0629 \u0631\u0642\u0645\u064a\u0629 LCD<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062f\u062e\u0648\u0644<\/th>\n<td>IP66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pressure rating, temperature limit, power supply and outputs depend on the selected configuration. Confirm material and seal compatibility before ordering.<\/p>\n<h2>\u0646\u0637\u0627\u0642\u0627\u062a \u0627\u0644\u062a\u062f\u0641\u0642<\/h2>\n<p>Select the flow range using the nominal diameter, liquid viscosity and required accuracy. All flow values below are in m\u00b3\/h; viscosity values are in mPa\u00b7s. A dash means the catalogue does not specify a range for that combination.<\/p>\n<p><strong>Liquid viscosity: 0.6\u20132 mPa\u00b7s<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Flow at 0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">Flow at 0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.2\u20130.4<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.6\u20131.5<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.8\u20133<\/td>\n<td>1.5\u20133<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>1.2\u20136<\/td>\n<td>3\u20136<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>5\u201315<\/td>\n<td>8\u201315<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>6\u201324<\/td>\n<td>12\u201324<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>10\u201340<\/td>\n<td>20\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>10\u201340<\/td>\n<td>20\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>30\u2013100<\/td>\n<td>40\u2013100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>45\u2013190<\/td>\n<td>90\u2013190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>68\u2013340<\/td>\n<td>170\u2013340<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Liquid viscosity: 2\u2013200 mPa\u00b7s<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Flow at 0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">Flow at 0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.08\u20130.4<\/td>\n<td>0.2\u20130.4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.3\u20131.5<\/td>\n<td>0.5\u20131.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.6\u20133<\/td>\n<td>1\u20133<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.8\u20136<\/td>\n<td>1.2\u20136<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>3\u201315<\/td>\n<td>5\u201315<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>4\u201324<\/td>\n<td>8\u201324<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>8\u201340<\/td>\n<td>10\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>8\u201340<\/td>\n<td>10\u201340<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>15\u2013100<\/td>\n<td>20\u2013100<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>34\u2013190<\/td>\n<td>56\u2013190<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>56\u2013340<\/td>\n<td>68\u2013340<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Liquid viscosity: 200\u20131000 mPa\u00b7s<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Flow at 0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">Flow at 0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.04\u20130.3<\/td>\n<td>0.08\u20130.3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.2\u20131.0<\/td>\n<td>0.3\u20131.0<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.4\u20132.1<\/td>\n<td>0.6\u20132.1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.6\u20134.2<\/td>\n<td>1\u20134.2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>2.1\u201310.5<\/td>\n<td>3\u201310.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>2.4\u201316.8<\/td>\n<td>4\u201316.8<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>6\u201328<\/td>\n<td>8\u201328<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>6\u201328<\/td>\n<td>8\u201328<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>10\u201370<\/td>\n<td>15\u201370<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>27\u2013133<\/td>\n<td>34\u2013133<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>48\u2013238<\/td>\n<td>56\u2013238<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Liquid viscosity: 1000\u20132000 mPa\u00b7s<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Size<\/th>\n<th scope=\"col\">Flow at 0.5% accuracy (m\u00b3\/h)<\/th>\n<th scope=\"col\">Flow at 0.2% accuracy (m\u00b3\/h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">DN10<\/th>\n<td>0.03\u20130.2<\/td>\n<td>0.06\u20130.2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN15<\/th>\n<td>0.1\u20130.7<\/td>\n<td>0.2\u20130.7<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN20<\/th>\n<td>0.25\u20131.5<\/td>\n<td>0.5\u20131.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN25<\/th>\n<td>0.6\u20133<\/td>\n<td>0.8\u20133<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN40<\/th>\n<td>1.0\u20137.5<\/td>\n<td>2\u20137.5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN50<\/th>\n<td>2\u201312<\/td>\n<td>3\u201312<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN65<\/th>\n<td>4\u201320<\/td>\n<td>6\u201320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN80<\/th>\n<td>4\u201320<\/td>\n<td>6\u201320<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN100<\/th>\n<td>10\u201350<\/td>\n<td>12\u201350<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN150<\/th>\n<td>19\u201395<\/td>\n<td>30\u201395<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DN200<\/th>\n<td>34\u2013170<\/td>\n<td>50\u2013170<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Applications and Media<\/h2>\n<p>Applications include petroleum and petrochemical processing, chemicals, environmental protection, marine systems, metallurgy, power generation, transportation, food processing, pharmaceuticals, defense and research.<\/p>\n<p>Typical media include clean oils and petroleum products, diesel, lubricating oils, adhesives, emulsions, asphalt, resins and syrups. Some acidic or alkaline liquids can be measured with compatible materials and seals. Select the meter for the actual medium and operating conditions; application suitability does not imply a particular hygienic or industry certification.<\/p>\n<h2 id=\"model-selection\">\u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0645\u0648\u0630\u062c<\/h2>\n<p>Base model: <strong>ADDA-FL-TY<\/strong>. The following codes identify available configuration options; confirm the complete model combination before ordering. Power supply and signal compatibility depend on the selected configuration.<\/p>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">\u0639\u0646\u0635\u0631<\/th>\n<th scope=\"col\">\u0634\u0641\u0631\u0629<\/th>\n<th scope=\"col\">\u062e\u064a\u0627\u0631<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Product series<\/th>\n<td>\u063a\u064a\u063a\u0627\u0648\u0627\u0637<\/td>\n<td>High-temperature version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product series<\/th>\n<td>\u062c\u064a \u0625\u0646<\/td>\n<td>High-viscosity version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product series<\/th>\n<td>\u062c\u064a \u062a\u064a<\/td>\n<td>Jacketed version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal diameter<\/th>\n<td>DN10\u2013DN200<\/td>\n<td>Specify the required nominal diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0636\u063a\u0637<\/th>\n<td>PN10 \u0648PN63<\/td>\n<td>Specify the flange standard and sealing face when ordering<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0645\u0627\u062f\u0629<\/th>\n<td>4<\/td>\n<td>304 \u0633\u062a\u0627\u0646\u0644\u0633 \u0633\u062a\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0645\u0627\u062f\u0629<\/th>\n<td>6<\/td>\n<td>316 \u0644\u062a\u0631 \u0633\u062a\u0627\u0646\u0644\u0633 \u0633\u062a\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>A<\/td>\n<td>\u0646\u0628\u0636 + 4 &amp; 20 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>B<\/td>\n<td>\u0646\u0628\u0636 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0633\u0644\u0627\u0643<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>C<\/td>\n<td>\u0633\u0644\u0643\u064a\u0646 4 \u00b7 20 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>D<\/td>\n<td>Three-wire 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>E<\/td>\n<td>\u0646\u0628\u0636 + 4 \u0628\u0648\u0635\u0629 20 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631 + Modbus RTU RS485<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Output signal<\/th>\n<td>F<\/td>\n<td>\u0646\u0628\u0636 + 4 \u0628\u0648\u0635\u0629 20 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631 + Modbus RTU RS485\u060c \u0645\u0639 \u0647\u0627\u0631\u062a<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/th>\n<td>S<\/td>\n<td>M20 \u00d7 1.5\u060c PVC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/th>\n<td>M<\/td>\n<td>M20 \u00d7 1.5\u060c SUS304<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062a\u0648\u0635\u064a\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a<\/th>\n<td>N<\/td>\n<td>1\/2 \u0645\u0639\u0627\u0647\u062f\u0629 \u062d\u0638\u0631 \u0627\u0644\u0627\u0646\u062a\u0634\u0627\u0631 \u0627\u0644\u0646\u0648\u0648\u064a\u060c SUS304<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062f\u0642\u0629<\/th>\n<td>1<\/td>\n<td>\u00b10.5% FS.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062f\u0642\u0629<\/th>\n<td>2<\/td>\n<td>\u00b10.2% FS.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0627\u0646\u0641\u062c\u0627\u0631<\/th>\n<td>N<\/td>\n<td>Non-explosion-proof version<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0627\u0646\u0641\u062c\u0627\u0631<\/th>\n<td>D<\/td>\n<td>Flameproof option: Ex db IIC T6 Gb<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard version is identified as GC in the flow-range table. Explosion protection is an optional configuration, not a rating shared by every version. Confirm the marking and documentation for the instrument supplied.<\/p>\n<h2 id=\"dimensions\">\u0623\u0628\u0639\u0627\u062f<\/h2>\n<p>All linear dimensions below are in millimetres (mm). N is the number of bolt holes and \u00d8 is the bolt-hole diameter. Click each drawing to view its full-size image.<\/p>\n<h3>DN10 to DN50 and DN65 DN80<\/h3>\n<p><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80.png\"><img decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80.png\" alt=\"ADDA-FL-TY dimensional drawing for DN10 to DN50 and DN65 DN80 oval gear flow meters\" width=\"701\" height=\"348\" class=\"aligncenter size-full wp-image-4011\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80.png 701w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80-300x149.png 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80-18x9.png 18w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn10-dn80-600x298.png 600w\" sizes=\"(max-width: 701px) 100vw, 701px\" \/><\/a><\/p>\n<h3>DN100<\/h3>\n<p><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn100.png\"><img decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn100.png\" alt=\"ADDA-FL-TY DN100 oval gear flow meter dimensional drawing with L H B C I D D1 and bolt hole references\" width=\"604\" height=\"269\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn100.png 604w\" class=\"aligncenter size-full wp-image-4012\" \/><\/a><\/p>\n<h3>DN150 and DN200<\/h3>\n<p><a href=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn150-dn200.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn150-dn200.jpg\" alt=\"ADDA-FL-TY dimensional drawing for DN150 and DN200 oval gear flow meters\" width=\"596\" height=\"279\" class=\"aligncenter size-full wp-image-4013\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn150-dn200.jpg 596w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn150-dn200-300x140.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/10\/adda-fl-ty-dimensions-dn150-dn200-18x8.jpg 18w\" sizes=\"(max-width: 596px) 100vw, 596px\" \/><\/a><\/p>\n<h3>Overall Dimensions<\/h3>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">L<\/th>\n<th scope=\"col\">H<\/th>\n<th scope=\"col\">B<\/th>\n<th scope=\"col\">C<\/th>\n<th scope=\"col\">I<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">10<\/th>\n<td>170<\/td>\n<td>100<\/td>\n<td>218<\/td>\n<td>140<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>200<\/td>\n<td>120<\/td>\n<td>238<\/td>\n<td>160<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>230<\/td>\n<td>150<\/td>\n<td>243<\/td>\n<td>165<\/td>\n<td>58<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>260<\/td>\n<td>182<\/td>\n<td>246<\/td>\n<td>168<\/td>\n<td>64<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>265<\/td>\n<td>182<\/td>\n<td>282<\/td>\n<td>204<\/td>\n<td>77<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>265<\/td>\n<td>182<\/td>\n<td>291<\/td>\n<td>213<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>350<\/td>\n<td>255<\/td>\n<td>380<\/td>\n<td>275<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>350<\/td>\n<td>255<\/td>\n<td>380<\/td>\n<td>275<\/td>\n<td>125<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>515<\/td>\n<td>418<\/td>\n<td>468<\/td>\n<td>338<\/td>\n<td>131<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>540<\/td>\n<td>510<\/td>\n<td>557<\/td>\n<td>377<\/td>\n<td>210<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>650<\/td>\n<td>650<\/td>\n<td>624<\/td>\n<td>436<\/td>\n<td>247<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Flange and Bolt Dimensions<\/h3>\n<table>\n<thead>\n<tr>\n<th scope=\"col\">DN<\/th>\n<th scope=\"col\">D<\/th>\n<th scope=\"col\">D1<\/th>\n<th scope=\"col\">N<\/th>\n<th scope=\"col\">\u00d8<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">10<\/th>\n<td>90<\/td>\n<td>60<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">15<\/th>\n<td>95<\/td>\n<td>65<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">20<\/th>\n<td>105<\/td>\n<td>75<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">25<\/th>\n<td>115<\/td>\n<td>85<\/td>\n<td>4<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">40<\/th>\n<td>150<\/td>\n<td>110<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">50<\/th>\n<td>165<\/td>\n<td>125<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">65<\/th>\n<td>185<\/td>\n<td>145<\/td>\n<td>4<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80<\/th>\n<td>200<\/td>\n<td>160<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">100<\/th>\n<td>220<\/td>\n<td>180<\/td>\n<td>8<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">150<\/th>\n<td>285<\/td>\n<td>240<\/td>\n<td>8<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">200<\/th>\n<td>340<\/td>\n<td>295<\/td>\n<td>12<\/td>\n<td>23<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Flange basis:<\/strong> Flange dimensions are based on a pressure rating of 1.6 MPa. Overall length and flange dimensions can be customized.<\/p>\n<p><strong>High-temperature version:<\/strong> For DN15\u2013DN50, add 100 mm to dimension B for the thermal extension tube. This allowance does not apply to the other sizes listed above.<\/p>\n<h2>Selection and Ordering<\/h2>\n<p>Provide the liquid name, viscosity at operating temperature, minimum and maximum flow, pipe diameter, operating pressure and temperature, flange standard, preferred power supply and required output. The high-viscosity and high-temperature versions should be selected for the corresponding service conditions. Confirm the applicable configuration with ADDA before ordering.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0645\u0642\u064a\u0627\u0633 \u062a\u062f\u0641\u0642 \u0627\u0644\u0625\u0632\u0627\u062d\u0629 \u0627\u0644\u0625\u064a\u062c\u0627\u0628\u064a\u0629 \u0644\u0644\u0633\u0648\u0627\u0626\u0644 \u0627\u0644\u0646\u0638\u064a\u0641\u0629 \u0648\u0627\u0644\u0632\u064a\u0648\u062a \u0648\u0627\u0644\u0648\u0642\u0648\u062f \u0648\u0627\u0644\u0648\u0633\u0627\u0626\u0637 \u0627\u0644\u0644\u0632\u062c\u0629. \u0645\u062a\u0648\u0641\u0631 \u0641\u064a DN10 wondN200 \u0645\u0639 \u0634\u0627\u0634\u0629 LCD\u060c \u0648\u062f\u0642\u0629 0.5% (0.2% \u0627\u062e\u062a\u064a\u0627\u0631\u064a)\u060c \u0648\u062e\u064a\u0627\u0631\u0627\u062a \u0625\u062e\u0631\u0627\u062c \u0646\u0628\u0636 4.50 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631 \u0623\u0648 Modbus RTU RS485.<\/p>","protected":false},"featured_media":4008,"template":"","meta":{"rank_math_title":"ADDA-FL-TY Oval Gear Flow Meter | Liquid Volume Metering","rank_math_description":"Explore the ADDA-FL-TY oval gear flow meter for clean liquids, oils and fuels, with positive displacement measurement and selectable signal outputs.","rank_math_canonical_url":"","rank_math_focus_keyword":"Oval Gear Flow Meter"},"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-4007","product","type-product","status-publish","has-post-thumbnail","product_cat-flow-meters","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product\/4007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media\/4008"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media?parent=4007"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_brand?post=4007"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_cat?post=4007"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/product_tag?post=4007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}