{"id":4109,"date":"2026-11-02T08:00:00","date_gmt":"2026-11-02T08:00:00","guid":{"rendered":"https:\/\/www.addameter.com\/?p=4109"},"modified":"2026-11-04T02:13:15","modified_gmt":"2026-11-04T02:13:15","slug":"mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define","status":"publish","type":"post","link":"https:\/\/www.addameter.com\/ar\/mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0636\u063a\u0637 MEMS: \u0645\u0627 \u0627\u0644\u0630\u064a \u062a\u062d\u062f\u062f\u0647 \u0634\u0631\u064a\u062d\u0629 \u0627\u0644\u0627\u0633\u062a\u0634\u0639\u0627\u0631 \u0648\u0645\u0627 \u0644\u0627 \u062a\u062d\u062f\u062f\u0647"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/h2><nav><ul><li class=\"\"><a href=\"#mems-pressure-transmitter-measurement-basis\">Mems pressure transmitter: measurement basis<\/a><\/li><li class=\"\"><a href=\"#range-and-operating-envelope\">\u0627\u0644\u0646\u0637\u0627\u0642 \u0648\u0645\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/a><\/li><li class=\"\"><a href=\"#medium-and-material-review\">\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u062a\u0648\u0633\u0637\u0629 \u0648\u0645\u0627\u062f\u064a\u0629<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-installation-details\">Mems pressure transmitter: installation details<\/a><\/li><li class=\"\"><a href=\"#signal-and-configuration\">\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-verification-plan\">Mems pressure transmitter: verification plan<\/a><\/li><li class=\"\"><a href=\"#maintenance-and-fault-checks\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0623\u062e\u0637\u0627\u0621<\/a><\/li><li class=\"\"><a href=\"#mems-pressure-transmitter-specification-for-adda\">Mems pressure transmitter: specification for ADDA<\/a><\/li><li class=\"\"><a href=\"#practical-review-what-the-sensing-chip-does-and-does-not-define\">Practical review: What the Sensing Chip Does and Does Not Define<\/a><\/li><li class=\"\"><a href=\"#technology-and-configuration-comparison\">\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u062a\u0643\u0646\u0648\u0644\u0648\u062c\u064a\u0627 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646<\/a><\/li><li class=\"\"><a href=\"#frequently-asked-questions\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u062f\u0627\u0648\u0644\u0629<\/a><ul><li class=\"\"><a href=\"#faq-question-12-1\">What should be confirmed first for mems pressure transmitter?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-2\">Which information does ADDA need for a mems pressure transmitter inquiry?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-3\">How should mems pressure transmitter acceptance be documented?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-4\">Can one mems pressure transmitter setting be used for every operating condition?<\/a><\/li><li class=\"\"><a href=\"#faq-question-12-5\">When should the mems pressure transmitter configuration be reviewed again?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Mems pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on what the Sensing Chip Does and Does Not Define in a silicon or MEMS pressure assembly on an OEM machine. The aim is to build an error budget around the value the process actually needs and turn that review into a configuration that can be installed, checked and maintained.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0647\u0646\u062f\u0633\u064a\u0646 \u0648\u0641\u0631\u0642 \u0627\u0644\u0634\u0631\u0627\u0621\u060c \u0641\u0625\u0646 \u0646\u0642\u0637\u0629 \u0627\u0644\u0628\u062f\u0627\u064a\u0629 \u0627\u0644\u0645\u0641\u064a\u062f\u0629 \u0647\u064a \u0642\u064a\u0645\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0627\u0644\u0648\u062b\u0648\u0642 \u0628\u0647\u0627\u060c \u0648\u0627\u0644\u0634\u0631\u0648\u0637 \u0627\u0644\u062a\u064a \u064a\u0645\u0643\u0646 \u0623\u0646 \u062a\u062c\u0639\u0644\u0647\u0627 \u062e\u0627\u0637\u0626\u0629 \u0648\u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u0644\u0627\u0632\u0645\u0629 \u0642\u0628\u0644 \u0627\u0644\u0642\u0628\u0648\u0644. \u062a\u0631\u0628\u0637 \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u062a\u0627\u0644\u064a\u0629 \u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0627\u0633\u062a\u0634\u0639\u0627\u0631 \u0628\u0627\u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0645\u0627\u062f\u064a \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u0627\u0633\u062a\u0642\u0628\u0627\u0644. \u0627\u0644\u0623\u0645\u062b\u0644\u0629 \u0627\u0644\u0639\u062f\u062f\u064a\u0629 \u0647\u064a \u062d\u0633\u0627\u0628\u0627\u062a \u062a\u0648\u0636\u064a\u062d\u064a\u0629\u060c \u0641\u064a \u062d\u064a\u0646 \u064a\u0646\u0628\u063a\u064a \u062a\u0623\u0643\u064a\u062f \u062d\u062f\u0648\u062f \u0648\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c \u0627\u0644\u0646\u0647\u0627\u0626\u064a \u0644\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0637\u0644\u0648\u0628.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg\" alt=\"ADDA pressure instrument with local digital display\" class=\"wp-image-1152\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-7-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 id=\"mems-pressure-transmitter-measurement-basis\" class=\"wp-block-heading\">Mems pressure transmitter: measurement basis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u064a\u062a\u0645 \u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u0636\u063a\u0637 \u0639\u0646\u062f \u0627\u0644\u062d\u062c\u0627\u0628 \u0627\u0644\u062d\u0627\u062c\u0632 \u0625\u0644\u0649 \u0642\u064a\u0627\u0633 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062b\u0645 \u0625\u0644\u0649 \u0645\u062e\u0631\u062c \u0645\u0643\u0648\u0646. \u062a\u0633\u062a\u062e\u062f\u0645 \u0623\u062f\u0627\u0629 \u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u062c\u0648\u064a \u0643\u0645\u0631\u062c\u0639 \u0644\u0647\u0627. \u062a\u0633\u062a\u062e\u062f\u0645 \u0627\u0644\u0623\u062f\u0627\u0629 \u0627\u0644\u0645\u0637\u0644\u0642\u0629 \u0645\u0631\u062c\u0639 \u0641\u0631\u0627\u063a \u0645\u063a\u0644\u0642. \u062a\u0639\u062f \u0645\u0637\u0627\u0628\u0642\u0629 \u0647\u0630\u0627 \u0627\u0644\u0645\u0631\u062c\u0639 \u0644\u062d\u0633\u0627\u0628 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0623\u0643\u062b\u0631 \u0623\u0647\u0645\u064a\u0629 \u0645\u0646 \u0625\u0636\u0627\u0641\u0629 \u062f\u0642\u0629 \u0627\u0644\u0639\u0631\u0636. \u0641\u064a \u0639\u0646\u0635\u0631 \u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0636\u063a\u0637\u060c \u064a\u063a\u064a\u0631 \u0625\u062c\u0647\u0627\u062f \u0627\u0644\u062d\u062c\u0627\u0628 \u0627\u0644\u062d\u0627\u062c\u0632 \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629. \u064a\u0639\u0627\u0644\u062c \u0627\u0644\u062a\u0639\u0648\u064a\u0636 \u0627\u0644\u0639\u0646\u0635\u0631 \u0627\u0644\u0645\u062d\u062f\u062f \u0648\u0633\u0644\u0648\u0643 \u0627\u0644\u062a\u062c\u0645\u064a\u0639\u061b \u0644\u0627 \u064a\u062b\u0628\u062a \u0627\u0644\u062a\u0648\u0627\u0641\u0642 \u0644\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0639\u0645\u0644\u064a\u0629.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The mems pressure transmitter review should establish one consistent physical basis. Define the quantity being compared and the tolerance for acceptance. Calibration establishes the relationship to a reference under stated conditions; any adjustment should be identified separately in the work record.<\/p>\n\n\n\n<h2 id=\"range-and-operating-envelope\" class=\"wp-block-heading\">\u0627\u0644\u0646\u0637\u0627\u0642 \u0648\u0645\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The operating span must cover the lowest useful reading and the highest normal condition. Startup spikes, cleaning pressure and accidental isolation can impose different demands. Measuring range, allowable overload and pressure boundary rating are separate quantities; a larger electrical span cannot compensate for an inadequate mechanical rating. Review the complete calibrated assembly rather than comparing chip technology in isolation. Mechanical packaging, temperature effects and the selected range remain part of the measurement error budget.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For mems pressure transmitter, the selected endpoints need a documented operating basis. Translate each stated error into the same engineering unit before comparison. Include the low end of normal operation, where a fixed full-scale term can represent a large fraction of the actual reading.<\/p>\n\n\n\n<h2 id=\"medium-and-material-review\" class=\"wp-block-heading\">\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u062a\u0648\u0633\u0637\u0629 \u0648\u0645\u0627\u062f\u064a\u0629<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter specification needs the actual exposure conditions. List process connection, wetted parts and environmental requirements. Include drawing references where a nominal description leaves geometry unclear. Avoid relying on a marketing family name as the assembly specification.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-installation-details\" class=\"wp-block-heading\">Mems pressure transmitter: installation details<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The installed mems pressure transmitter should follow the accepted application drawing. Keep avoidable installation effects out of the measurement where practical. Correct placement, representative conditions and suitable pressure or thermal paths can improve the installed result more directly than selecting a tighter electronics specification.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg\" alt=\"ADDA differential pressure transmitter with two process connections\" class=\"wp-image-1155\" srcset=\"https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4.jpg 800w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-300x300.jpg 300w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-150x150.jpg 150w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-768x768.jpg 768w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-600x600.jpg 600w, https:\/\/www.addameter.com\/wp-content\/uploads\/2026\/07\/cpfl-4-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 id=\"signal-and-configuration\" class=\"wp-block-heading\">\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For mems pressure transmitter, the receiving value must retain the intended interpretation. Compare local measurement, output signal, receiving-system value and operator label. Verify where conversion and compensation occur. Each stage should represent the same intended quantity.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-verification-plan\" class=\"wp-block-heading\">Mems pressure transmitter: verification plan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A pressure source tests the sensing chain; current injection tests the receiving loop. These checks answer different questions. Record increasing and decreasing readings after stabilization, then retain the configuration and reference information so a future technician can reproduce the comparison. Review the complete calibrated assembly rather than comparing chip technology in isolation. Mechanical packaging, temperature effects and the selected range remain part of the measurement error budget.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter acceptance check needs a reproducible comparison. Compare several points and directions where appropriate, allowing stabilization. Keep raw reference and instrument readings so the error can be evaluated in engineering units rather than only as a pass label.<\/p>\n\n\n\n<h2 id=\"maintenance-and-fault-checks\" class=\"wp-block-heading\">\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0627\u0644\u0623\u062e\u0637\u0627\u0621<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The mems pressure transmitter service record should explain the observed condition. Investigate whether a disagreement changes with flow, temperature, pressure or range. A changing error suggests a different cause from a fixed scaling mismatch. Preserve the raw observations before applying correction.<\/p>\n\n\n\n<h2 id=\"mems-pressure-transmitter-specification-for-adda\" class=\"wp-block-heading\">Mems pressure transmitter: specification for ADDA<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A mems pressure transmitter inquiry is strongest when its assumptions are explicit. Issue one reconciled tag sheet with the final configuration. The purchase order, drawing and controls data should refer to the same selected version and revision.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0645\u0631\u0627\u062c\u0639\u0629 <a href=\"https:\/\/www.addameter.com\/ar\/product\/smart-pressure-transmitter\/\">\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u062a\u0643\u0648\u064a\u0646 \u062c\u0647\u0627\u0632 \u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0630\u0643\u064a<\/a> \u0648 \u0627\u0644 <a href=\"https:\/\/www.addameter.com\/ar\/products\/\">\u0645\u062d\u0641\u0638\u0629 \u0645\u0646\u062a\u062c\u0627\u062a ADDA<\/a> \u0628\u062c\u0627\u0646\u0628 \u0648\u0631\u0642\u0629 \u0627\u0644\u0639\u0644\u0627\u0645\u0627\u062a. \u062a\u062d\u062f\u062f \u0647\u0630\u0647 \u0627\u0644\u0631\u0648\u0627\u0628\u0637 \u0639\u0627\u0626\u0644\u0629 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629\u061b \u0641\u0647\u064a \u0644\u0627 \u062a\u062d\u0644 \u0645\u062d\u0644 \u062a\u0623\u0643\u064a\u062f \u0627\u0644\u0645\u0648\u0627\u062f \u0648\u0627\u0644\u0648\u0627\u062c\u0647\u0627\u062a \u0648\u062d\u062f\u0648\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629 \u0628\u062f\u0642\u0629.<\/p>\n\n\n\n<h2 id=\"practical-review-what-the-sensing-chip-does-and-does-not-define\" class=\"wp-block-heading\">Practical review: What the Sensing Chip Does and Does Not Define<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0646\u0637\u0627\u0642 \u0642\u064a\u0627\u0633 \u062a\u0648\u0636\u064a\u062d\u064a 0 ber10 bar\u060c \u064a\u0645\u062b\u0644 12 \u0645\u0644\u0644\u064a \u0623\u0645\u0628\u064a\u0631 5 \u0628\u0627\u0631 \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u0648\u0646 \u0627\u0644\u0625\u062e\u0631\u0627\u062c \u062e\u0637\u064a\u064b\u0627. \u062c\u0647\u0627\u0632 \u0625\u0631\u0633\u0627\u0644 \u0639\u0644\u0649 \u0645\u062f\u0649 0 mar16 \u0628\u0627\u0631 \u064a\u0639\u0637\u064a 8 \u0628\u0627\u0631 \u0641\u064a \u0646\u0641\u0633 \u0627\u0644\u062a\u064a\u0627\u0631. \u0647\u0630\u0647 \u0623\u0645\u062b\u0644\u0629 \u062d\u0633\u0627\u0628\u064a\u0629\u060c \u0648\u0644\u064a\u0633\u062a \u062a\u0642\u064a\u064a\u0645\u0627\u062a \u0646\u0645\u0648\u0630\u062c\u064a\u0629.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To apply this example to mems pressure transmitter, begin with the actual drawing and collect the inputs that what the Sensing Chip Does and Does Not Define requires. Mark each input as measured, specified or still awaiting confirmation. Compare the result with the normal operating point, then repeat the review at the relevant low or high condition. This makes an assumption visible before it becomes an unexplained offset in the control system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u064a\u062c\u0628 \u0623\u0646 \u062a\u062a\u0631\u0643 \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u062b\u0644\u0627\u062b\u0629 \u0633\u062c\u0644\u0627\u062a \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645: \u0627\u0644\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u0645\u0627\u062f\u064a \u0627\u0644\u0630\u064a \u062a\u0645 \u0641\u062d\u0635\u0647\u060c \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0630\u064a \u064a\u0646\u0641\u0630 \u0627\u0644\u062a\u0641\u0633\u064a\u0631 \u0627\u0644\u0645\u0642\u0635\u0648\u062f\u060c \u0648\u0627\u0644\u0645\u0644\u0627\u062d\u0638\u0627\u062a \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u0629 \u0644\u0644\u062d\u0643\u0645 \u0639\u0644\u0649 \u0627\u0644\u0646\u062a\u064a\u062c\u0629. \u0625\u0630\u0627 \u062d\u062f\u062b \u0623\u064a \u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u062a\u063a\u064a\u064a\u0631\u0627\u062a\u060c \u062d\u062f\u062f \u0627\u0644\u0627\u0633\u062a\u0646\u062a\u0627\u062c\u0627\u062a \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u062a\u0643\u0631\u0627\u0631\u0647\u0627. \u0648\u0647\u0630\u0627 \u0645\u0641\u064a\u062f \u0628\u0634\u0643\u0644 \u062e\u0627\u0635 \u0639\u0646\u062f\u0645\u0627 \u064a\u0643\u0648\u0646 \u0644\u0644\u0623\u062f\u0627\u0629 \u0627\u0644\u0628\u062f\u064a\u0644\u0629 \u0646\u0641\u0633 \u0627\u0633\u0645 \u0627\u0644\u0639\u0627\u0626\u0644\u0629 \u0648\u0644\u0643\u0646 \u0644\u0647\u0627 \u0646\u0637\u0627\u0642 \u0623\u0648 \u0627\u062a\u0635\u0627\u0644 \u0623\u0648 \u0645\u0633\u0628\u0627\u0631 \u0623\u0648 \u0645\u062e\u0631\u062c \u0623\u0648 \u062e\u064a\u0627\u0631 \u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0627\u062a \u0645\u062e\u062a\u0644\u0641.<\/p>\n\n\n\n<h2 id=\"technology-and-configuration-comparison\" class=\"wp-block-heading\">\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u062a\u0643\u0646\u0648\u0644\u0648\u062c\u064a\u0627 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u062e\u064a\u0627\u0631<\/th><th>\u0627\u0644\u0646\u0638\u0631 \u0641\u064a \u0627\u0644\u0637\u0644\u0628<\/th><th>\u0627\u0644\u0623\u062f\u0644\u0629 \u0644\u0644\u0637\u0644\u0628<\/th><\/tr><\/thead><tbody><tr><td>\u0642\u064a\u0627\u0633 \u0627\u0644\u0642\u064a\u0627\u0633<\/td><td>\u0627\u0644\u0645\u0631\u062c\u0639 \u0627\u0644\u062c\u0648\u064a \u0648\u0636\u063a\u0637 \u0627\u0644\u062e\u0637 \u0627\u0644\u0639\u0627\u062f\u064a<\/td><td>\u062a\u0645 \u062a\u0633\u062c\u064a\u0644 \u0623\u0633\u0627\u0633 \u0627\u0644\u062e\u0637\u0623 \u0648\u0627\u0644\u0645\u0642\u0627\u0645<\/td><\/tr><tr><td>\u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u0645\u0637\u0644\u0642<\/td><td>\u0645\u0631\u062c\u0639 \u0627\u0644\u0641\u0631\u0627\u063a \u0648\u062d\u0633\u0627\u0628\u0627\u062a \u0627\u0644\u0636\u063a\u0637<\/td><td>\u062a\u0639\u062a\u0628\u0631 \u0627\u0644\u0645\u0633\u0627\u0647\u0645\u0627\u062a \u0627\u0644\u0645\u062b\u0628\u062a\u0629<\/td><\/tr><tr><td>\u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u0641\u0627\u0636\u0644\u064a<\/td><td>\u0646\u0642\u0637\u062a\u0627 \u0639\u0645\u0644\u064a\u0629 \u0648\u0648\u0627\u062c\u0628\u0627\u062a \u0625\u0633\u0642\u0627\u0637 \u0627\u0644\u0636\u063a\u0637<\/td><td>\u0627\u0644\u062a\u0633\u0627\u0645\u062d \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u062d\u062f\u062f \u0641\u064a \u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0629<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use this comparison to structure a mems pressure transmitter review, rather than to rank every technology for every process. The preferred option is the one that meets the required measurement task within the available installation and maintenance conditions. Compare supplier offers against the same operating envelope and ask for explicit exceptions when an option cannot meet one of the requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u062e\u0644\u0641\u064a\u0629 \u0645\u0633\u062a\u0642\u0644\u0629\u060c \u0627\u0633\u062a\u0634\u0631 <a href=\"https:\/\/www.nist.gov\/programs-projects\/pressurevacuum-calibrations\" target=\"_blank\" rel=\"noopener\">\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0645\u0639\u0627\u064a\u0631\u0629 \u0627\u0644\u0636\u063a\u0637 \u0648\u0627\u0644\u0641\u0631\u0627\u063a NIST<\/a>. \u064a\u0648\u0641\u0631 \u0647\u0630\u0627 \u0627\u0644\u0645\u0631\u062c\u0639 \u0633\u064a\u0627\u0642\u064b\u0627 \u062a\u0642\u0646\u064a\u064b\u0627 \u0623\u0648 \u0642\u064a\u0627\u0633\u064a\u064b\u0627 \u0639\u0627\u0645\u064b\u0627. \u0644\u064a\u0633 \u062f\u0644\u064a\u0644\u0627\u064b \u0639\u0644\u0649 \u0623\u0646 \u0645\u0646\u062a\u062c\u064b\u0627 \u0645\u0639\u064a\u0646\u064b\u0627 \u0645\u0646 \u0645\u0646\u062a\u062c\u0627\u062a ADDA \u0642\u062f \u062a\u0645 \u0627\u0639\u062a\u0645\u0627\u062f\u0647 \u0623\u0648 \u0627\u0639\u062a\u0645\u0627\u062f\u0647 \u0623\u0648 \u0645\u0639\u0627\u064a\u0631\u062a\u0647 \u0645\u0646 \u0642\u0628\u0644 \u062a\u0644\u0643 \u0627\u0644\u0645\u0646\u0638\u0645\u0629.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Discuss your mems pressure transmitter application with ADDA.<\/strong> Send the operating data and drawing through the form below, including the specific issue of what the Sensing Chip Does and Does Not Define. Request a configuration review, the relevant product information and confirmation of any outstanding application assumptions before placing the order.<\/p>\n\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0645\u062a\u062f\u0627\u0648\u0644\u0629<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-12-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What should be confirmed first for mems pressure transmitter?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Start with the physical quantity, reference and operating task. For this application, the central issue is what the Sensing Chip Does and Does Not Define. Confirm the actual process conditions and the installation drawing before selecting a range or accepting a numerical comparison. This avoids choosing an instrument around a label while leaving the measurement basis unresolved.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Which information does ADDA need for a mems pressure transmitter inquiry?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>\u062a\u0648\u0641\u064a\u0631 \u0645\u0648\u0642\u0639 \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0648\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u062f\u0646\u0649 \u0648\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0648\u0627\u0644\u0648\u0633\u064a\u0637 \u0648\u0627\u062a\u0635\u0627\u0644 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0648\u0627\u0644\u0645\u062e\u0631\u062c\u0627\u062a \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629 \u0648\u0645\u0633\u0627\u062d\u0629 \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0627\u0644\u0645\u062a\u0627\u062d\u0629. \u0642\u0645 \u0628\u062a\u0636\u0645\u064a\u0646 \u0631\u0633\u0645 \u0644\u0645\u062c\u0645\u0648\u0639\u0629 \u0636\u063a\u0637 \u0627\u0644\u0633\u064a\u0644\u064a\u0643\u0648\u0646 \u0623\u0648 MEMS \u0639\u0644\u0649 \u062c\u0647\u0627\u0632 OEM\u060c \u0628\u0627\u0644\u0625\u0636\u0627\u0641\u0629 \u0625\u0644\u0649 \u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629. \u0627\u0637\u0644\u0628 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u062f\u0642\u064a\u0642 \u0627\u0644\u0645\u0639\u0631\u0648\u0636 \u0648\u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u0627\u062a\u060c \u062e\u0627\u0635\u0629 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0636\u0645\u0646 \u0639\u0627\u0626\u0644\u0629 \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c \u0627\u0644\u0639\u062f\u064a\u062f \u0645\u0646 \u0627\u0644\u0645\u0648\u0627\u062f \u0623\u0648 \u0627\u0644\u0648\u0627\u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How should mems pressure transmitter acceptance be documented?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>\u0642\u0645 \u0628\u062a\u0633\u062c\u064a\u0644 \u0627\u0644\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u0645\u062b\u0628\u062a \u0648\u0627\u0644\u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629\u060c \u062b\u0645 \u0627\u062d\u062a\u0641\u0638 \u0628\u0627\u0644\u0645\u0644\u0627\u062d\u0638\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u0648\u0636\u062d \u0627\u0644\u0645\u0647\u0645\u0629 \u0627\u0644\u0645\u0642\u0635\u0648\u062f\u0629. \u064a\u062c\u0628 \u0623\u0646 \u062a\u063a\u0637\u064a \u0627\u0644\u0645\u0631\u0627\u062c\u0639\u0629 \u0645\u0627 \u064a\u0644\u064a: \u0623\u0633\u0627\u0633 \u0627\u0644\u062e\u0637\u0623 \u0648\u0627\u0644\u0645\u0642\u0627\u0645 \u0627\u0644\u0645\u0633\u062c\u0644\u061b \u062a\u0645 \u0627\u0644\u0646\u0638\u0631 \u0641\u064a \u0627\u0644\u0645\u0633\u0627\u0647\u0645\u0627\u062a \u0627\u0644\u0645\u062b\u0628\u062a\u0629\u061b \u0627\u0644\u062a\u0633\u0627\u0645\u062d \u0645\u0639 \u0627\u0644\u0642\u0628\u0648\u0644 \u0627\u0644\u0645\u062d\u062f\u062f \u0641\u064a \u0648\u062d\u062f\u0627\u062a \u0627\u0644\u0639\u0645\u0644\u064a\u0629. \u062a\u062d\u062f\u064a\u062f \u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0648\u0623\u062c\u0632\u0627\u0621 \u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u0642\u064a\u0627\u0633 \u0627\u0644\u062a\u064a \u062a\u062a\u0636\u0645\u0646\u0647\u0627. \u062a\u0648\u0641\u0631 \u0627\u0644\u0645\u062d\u0627\u0643\u0627\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u0642\u0627\u0631\u0646\u0629 \u0627\u0644\u0645\u0627\u062f\u064a\u0629 \u0648\u0641\u062d\u0635 \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0623\u062f\u0644\u0629 \u0645\u062e\u062a\u0644\u0641\u0629 \u0648\u064a\u062c\u0628 \u0623\u0646 \u062a\u0638\u0644 \u062a\u062d\u0645\u0644 \u0639\u0644\u0627\u0645\u0627\u062a \u0648\u0627\u0636\u062d\u0629.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-4\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Can one mems pressure transmitter setting be used for every operating condition?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>\u0641\u0642\u0637 \u0625\u0630\u0627 \u062a\u0645\u062a \u0645\u0631\u0627\u062c\u0639\u0629 \u063a\u0644\u0627\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0643\u0627\u0645\u0644 \u0648\u0638\u0644\u062a \u0627\u0641\u062a\u0631\u0627\u0636\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633 \u0635\u0627\u0644\u062d\u0629. \u064a\u0645\u0643\u0646 \u0644\u0644\u062a\u063a\u064a\u0631\u0627\u062a \u0641\u064a \u062e\u0635\u0627\u0626\u0635 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0623\u0648 \u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0623\u0648 \u0627\u0644\u0647\u0646\u062f\u0633\u0629 \u0623\u0648 \u062a\u0648\u0642\u064a\u062a \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0623\u0646 \u062a\u063a\u064a\u0631 \u0627\u0644\u0646\u062a\u064a\u062c\u0629. \u062a\u062d\u062f\u064a\u062f \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u062a\u064a \u062a\u0634\u062a\u0631\u0643 \u0641\u064a \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0648\u0627\u0644\u062a\u064a \u062a\u062a\u0637\u0644\u0628 \u062a\u0642\u064a\u064a\u0645\u064b\u0627 \u0625\u0636\u0627\u0641\u064a\u064b\u0627\u061b \u0644\u0627 \u062a\u062e\u0641\u064a \u0641\u0631\u0642\u064b\u0627 \u063a\u064a\u0631 \u0645\u0628\u0631\u0631 \u0628\u0625\u0632\u0627\u062d\u0629 \u0639\u0631\u0636 \u062f\u0627\u0626\u0645\u0629.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-12-5\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">When should the mems pressure transmitter configuration be reviewed again?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>\u0642\u0645 \u0628\u0645\u0631\u0627\u062c\u0639\u062a\u0647 \u0628\u0639\u062f \u062a\u063a\u064a\u064a\u0631 \u0627\u0644\u0639\u0645\u0644\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629 \u0623\u0648 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0623\u062f\u0627\u0629 \u0623\u0648 \u062a\u0639\u062f\u064a\u0644 \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0623\u0648 \u062a\u0643\u0631\u0627\u0631 \u0627\u0644\u062e\u0644\u0627\u0641 \u063a\u064a\u0631 \u0627\u0644\u0645\u0628\u0631\u0631. \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0627\u0644\u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0648\u0627\u0644\u0645\u0644\u0627\u062d\u0638\u0627\u062a \u0627\u0644\u0633\u0627\u0628\u0642\u0629 \u062d\u062a\u0649 \u064a\u0645\u0643\u0646 \u062a\u0642\u064a\u064a\u0645 \u062a\u0623\u062b\u064a\u0631 \u0627\u0644\u062a\u063a\u064a\u064a\u0631. \u0627\u0644\u0647\u062f\u0641 \u0647\u0648 \u0625\u0639\u0627\u062f\u0629 \u0625\u0646\u062a\u0627\u062c \u0642\u064a\u0627\u0633 \u0645\u0648\u062b\u0648\u0642 \u0628\u0647 \u0641\u064a \u0638\u0644 \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u062c\u062f\u064a\u062f\u0629\u060c \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0645\u062c\u0631\u062f \u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0631\u0642\u0645 \u0645\u0623\u0644\u0648\u0641 \u0639\u0644\u0649 \u0627\u0644\u0634\u0627\u0634\u0629.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class='fluentform ff-default fluentform_wrapper_3 ffs_default_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" action=\"\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u5b98\u7f51\u8be2\u76d8<\/legend>        <div\n                style=\"display: none!important; position: absolute!important; transform: translateX(1000%)!important;\"\n                class=\"ff-el-group ff-hpsf-container\"\n        >\n            <div class=\"ff-el-input--label asterisk-right\">\n                <label for=\"ff_3_item_sf\" aria-label=\"\u064a\u0634\u062a\u0631\u0643\">\n                    \u064a\u0634\u062a\u0631\u0643                <\/label>\n            <\/div>\n            <div class=\"ff-el-input--content\">\n                <input type=\"text\"\n                       name=\"item_3__fluent_sf\"\n                       class=\"ff-el-form-control\"\n                       id=\"ff_3_item_sf\"\n                \/>\n            <\/div>\n        <\/div>\n        <input type='hidden' name='__fluent_form_embded_post_id' value='4109' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"fb1033f20e\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/ar\/wp-json\/wp\/v2\/posts\/4109\" \/><div data-name=\"ff_cn_id_1\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_input_text' id='label_ff_3_input_text' aria-label=\"\u0627\u0633\u0645\">\u0627\u0633\u0645<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text\" class=\"ff-el-form-control\" placeholder=\"\u0627\u0633\u0645\" data-name=\"input_text\" id=\"ff_3_input_text\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_subject' id='label_ff_3_subject' aria-label=\"\u0647\u0627\u062a\u0641\">\u0647\u0627\u062a\u0641<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"\u0647\u0627\u062a\u0641\" data-name=\"subject\" id=\"ff_3_subject\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email' aria-label=\"\u0628\u0631\u064a\u062f \u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\">\u0628\u0631\u064a\u062f \u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"\u0639\u0646\u0648\u0627\u0646 \u0627\u0644\u0628\u0631\u064a\u062f \u0627\u0644\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\" data-name=\"email\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_message' id='label_ff_3_message' aria-label=\"\u0631\u0633\u0627\u0644\u062a\u0643\">\u0631\u0633\u0627\u0644\u062a\u0643<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_3_message\" name=\"message\" id=\"ff_3_message\" class=\"ff-el-form-control\" placeholder=\"\u0631\u0633\u0627\u0644\u062a\u0643\" rows=\"5\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"\u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\">\u0625\u0631\u0633\u0627\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c<\/button><\/div><\/fieldset><input type=\"hidden\" name=\"trp-form-language\" value=\"ar\"\/><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/www.addameter.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"input_text\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>","protected":false},"excerpt":{"rendered":"<p>Mems pressure transmitter decisions become clearer when the measurement is tied to a defined operating task. This guide focuses on what the Sensing Chip Does and Does Not Define in a silicon or MEMS pressure assembly on an OEM machine. The aim is to build an error budget around the value the process actually needs [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":443,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Mems pressure transmitter | ADDA Guide","rank_math_description":"Mems pressure transmitter: what the Sensing Chip Does and Does Not Define. Review practical selection, installation and verification points with ADDA.","rank_math_canonical_url":"https:\/\/www.addameter.com\/mems-pressure-transmitter-what-the-sensing-chip-does-and-does-not-define\/","rank_math_focus_keyword":"mems pressure transmitter"},"categories":[22],"tags":[],"class_list":["post-4109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/posts\/4109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/comments?post=4109"}],"version-history":[{"count":2,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/posts\/4109\/revisions"}],"predecessor-version":[{"id":4656,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/posts\/4109\/revisions\/4656"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media\/443"}],"wp:attachment":[{"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/media?parent=4109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/categories?post=4109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.addameter.com\/ar\/wp-json\/wp\/v2\/tags?post=4109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}